Daniel  A.

Daniel A.

MEDB855DC3 Dryer not heating intermittently. Checked voltage. Red wire from motor to heater not seated fully. Reinserted. Verified normal temperature interior dryer. Normal operation after service. Instruct customer on venting/fire hazard

Near Desiree St, Canyon Lake, TX 78133
Nathaniel B.

Nathaniel B.

Model EB2SHKXVD02, Arrived on call for drain iced over and running on to floor and air return and supply blocked with ice preventing air to fresh food section,, cleared all ice from drain and evap coil and supply air and return air and all checks good, getting good air flow to fresh food section and installed new drain tube and all checks good, call complete, no water leaks at time of call, call complete, collected remaining balance of 172.67

Near Morgana Dr, Pflugerville, TX 78660
Nathaniel B.

Nathaniel B.

Model EB2SHKXVD02, Arrived on call for drain iced over and running on to floor and air return and supply blocked with ice preventing air to fresh food section,, cleared all ice from drain and evap coil and supply air and return air and all checks good, getting good air flow to fresh food section and installed new drain tube and all checks good, call complete, no water leaks at time of call, call complete, collected remaining balance of 172.67

Near Morgana Dr, Pflugerville, TX 78660
Carlos G.

Carlos G.

Arrived onsite for customer compliant popping noise.

Near Thornton Rd, Austin, TX 78704
Dona W.

Dona W.

Arrived on site for f3 e1 error, found trap to pressure hose clogged off with build up, customer stated that unit was not creating error on every load. Replaced trap. Filled, washed, drain, and spun accordingly with no error 2 x, all water connections dry. Discussed with customer possible over sudsing as well.

Near Sandyford Ct, Killeen, TX 76542
Thomas L.

Thomas L.

Arrived on site for no ice and no ice dispenser operation. Replaced failed icemaker controls and failed dispenser motor. Operations now test normal. All water connections were dry.

Near Pierce Dr, Kingsland, TX 78639
Daniel  A.

Daniel A.

WDT720PADM2 Dishwasher not draining (new home ). Check valve on drain hose not positioned properly/opening fully to allow water to drain. Verified drain pump operation. Checked water inlet and drain hoses. No leaks detected

Near Enclave Trail, New Braunfels, TX 78132
Dona W.

Dona W.

Arrived on site for unit shaking during cycle, found right hand side of washer front screw missing , screws on toe kick missing as well. Put screws back in unit and ran unit with clothing. Unit is running to spec, but flooring is weak causing some movement. Unit is on a pedestal. Leveled unit as much as possible. Customer will need to reinforce flooring. All water connections dry

Near Trimmier Rd, Killeen, TX 76542
Daniel  A.

Daniel A.

WRF767SDEM01 Not cooling in refrigerator compartment. Not defrosting/drain pan frozen over. Replaced and repositioned refrigerator evaporator fan motor/thermistor. Defrosted refrigerator evaporator. Normal operation after service

Near Wauford Way, New Braunfels, TX 78132
Connor M.

Connor M.

WED5000DW2 whirlpool dryer Arrived on site to test unit for not drying clothes well. Found lint on wrong side of the screen and no air move ent at exhaust outside of house. Vent line is newly installed and likely crushed during construction. No issue found with dryer. Instruct on proper venting and fire hazard.

Near Summerwood Dr, San Antonio, TX 78232
Nathaniel B.

Nathaniel B.

Model WFE515S0EB0, Arrived on call for sparking noise like unit is shorting when running top burners, found prior all 4 infinite switches are bad, replaced all 4 infinite switches and checked operation and all checked good, call complete.

Near Bayland St, Round Rock, TX 78664
Nathaniel B.

Nathaniel B.

Model WFE515S0EB0, Arrived on call for sparking noise like unit is shorting when running top burners, found prior all 4 infinite switches are bad, replaced all 4 infinite switches and checked operation and all checked good, call complete.

Near Bayland St, Round Rock, TX 78664
Carlos G.

Carlos G.

Arrived onsite for customer compliant of UI not responding. Checked components and found a faulty UI. Normal wear and tear. Removed and replaced UI assembly. Ran test cycle and all checks ok now. Job complete.

Near Thornton Rd, Austin, TX 78704
Carlos G.

Carlos G.

Arrived onsite for customer compliant of UI not responding. Checked components and found a faulty UI. Normal wear and tear. Removed and replaced UI assembly. Ran test cycle and all checks ok now. Job complete.

Near Thornton Rd, Austin, TX 78704
Connor M.

Connor M.

WFC310S0AB0 whirlpool oven Arrived on site to test unit for flames coming from rf bunrer. Found burnt up plug. Replaced plug and coil. Found lf and rr switches not regulating correctly. Ordering both for return. Sw approved 5/10

Near Silver Stream, San Antonio, TX 78259
Lou S.

Lou S.

arrived on site to inspect washer not dispensing cold water. I placed the unit in diagnostics and found that the unit would dispense cold water and hot and then both together. However, when I ran the unit on normal mode, the cold water would not dispense. I replaced the control and calibrated the unit then tested the unit. Again, the cold would dispense in test mode but when operating in normal wash mode, the cold would not dispense. I ohmed the water inlet valve and the valve is open. Office to order water inlet valve and schedule return service for 05/09/18. No water leaks observed during service.

Near Old 2243 W, Leander, TX 78641
Leonardo C.

Leonardo C.

Whirlpool gas range model WFG505M0BS3. Arrived on site to test unit for left front burner flames way to high. Test unit and found burner cap not sitting correctly making uneven flames. Installed cap correctly test unit and unit test good even flames on all burners.

Near Vestral Road, , TX
Thomas L.

Thomas L.

Arrived on site for Noisey operation. Found fresh food temp at 38 and freezer temp at -3. All operations were normal and quiet. Customer had defrosted the unit prior several days ago. Suspect defrost cycle problem. However defrost heater energized in diagnostics testing. All water connections were dry. Customer to observe u it operations.

Near N Hill St, Burnet, TX 78611
Dona W.

Dona W.

Arrived on site for range seems to hot. Found unit running a little high. Recalibrated unit. Showed customer how to calibrate machine. Unit checks good after recalibrate.

Near Joshua Taylor Dr, Killeen, TX 76549
Dona W.

Dona W.

Arrived on site for unit taking longer to heat, showed customer reheat, operations, timed cook operations, all options. Verified water is boiling within one and a half minutes. All operations checked good.

Near Joshua Taylor Dr, Killeen, TX 76549
Brandon C.

Brandon C.

Arrived on site for part hanger, I replaced Evap fan motor kit with support, uib, unit tested good.

Near Aspen Dr, Austin, TX 78737
Connor M.

Connor M.

WSZ57L18DM00 whirlpool refrigerator Arrived on site to test unit for condensation on upper left corner of ff compartment. Found gasket slightly pulled away from cabinet on corner. Corrected issue with heat gun. Unit working properly, no leaks detected.

Near Napoli, New Braunfels, TX 78132
Connor M.

Connor M.

WTW8540BW whirlpool washer Arrived on site to test unit for oil coming from under unit. Spun basket manually and fiund failed bearing likely caused by bad tub seal. Rotor covered in oil will need to replace. Allow 2 hours. Office to schedule directly.

Near Copper Creek, New Braunfels, TX 78132
Connor M.

Connor M.

WED8500BW0 whirlpool dryer Arrived on site to test unit for door not closing properly. Found failed door catch. Replaced and tested unit. Unit working properly. Instruct on proper venting and fire hazards.

Near Copper Creek, New Braunfels, TX 78132
Nathaniel B.

Nathaniel B.

Model WRS321SDHB00, Arrived on call for right fridge door has dent, will order right fresh food door, took pics, instructed customer that door orders take 6-8 weeks, office will reschedule with customer, as for dent on side of cabinet customer will need to call whirlpool customer service but it does not effect the unit see pic.

Near Adams St, Taylor, TX 76574
Nathaniel B.

Nathaniel B.

Model WRS321SDHB00, Arrived on call for right fridge door has dent, will order right fresh food door, took pics, instructed customer that door orders take 6-8 weeks, office will reschedule with customer, as for dent on side of cabinet customer will need to call whirlpool customer service but it does not effect the unit see pic.

Near Adams St, Taylor, TX 76574
Dona W.

Dona W.

Arrived on site for unit going off balance, found suspension rods sprung and causing unit to move all over. Also found gearcase with noise on spin, will need new drive block due to age. Will order new tub seal if new gearcase doesn't come with. Will need 2 hours ordered cnotes for repair and office will need to reschedule office closed. All water connections dry. MEL1M00DPL1

Near H K Allen Pkwy, Temple, TX 76502
Lou S.

Lou S.

Near S Ridge Cir, Georgetown, TX 78628
Connor M.

Connor M.

MHW8200FW0 maytag washer Arrived on site to test unit for shaking during use. Found unit on a pedestal, and placed over a void in the tile designed to catch water in the event of a leak. Left rear foot fully seated and not extended. Right rear foot fully extended about 2 inches. This will cause a wobbly point of contact in turn allowing certain loads to shake washer excessivley. Ran full diagnostic and confirmed no mechanical failures. Instruct customer on proper use and care. No leaks detected at time of service.

Near Ramble Ridge, San Antonio, TX 78266
Nathaniel B.

Nathaniel B.

Model MEDX655DW1, Autho. MEK8KEJEPL1 , Arrived on call fo dryer to hot on low settings, found that element shorted to housing of heating element on l2 side and when turned on timer to a heat setting of any kind with out pressing start element would come on, replaced element and checked operation and all checks good, call complete, dryer vent is clear.

Near Zion Ave, Taylor, TX 76574
Nathaniel B.

Nathaniel B.

Model MEDX655DW1, Autho. MEK8KEJEPL1 , Arrived on call fo dryer to hot on low settings, found that element shorted to housing of heating element on l2 side and when turned on timer to a heat setting of any kind with out pressing start element would come on, replaced element and checked operation and all checks good, call complete, dryer vent is clear.

Near Zion Ave, Taylor, TX 76574
Steve C.

Steve C.

Arrived on site for the unit Flame is too high. Found the unit is not converted to propane. Use the conversion kit and tested the unit. Unit ignite and heat properly and no gas leak present.

Near Berry Creek Dr, Georgetown, TX 78628
Steve C.

Steve C.

Arrived on site for the unit is not heating. Tested the unit and found the heating element has no continuity. Replaced the heating element and cleaned the inside of the unit. Unit works properly and advise customer to clean air vents every six months.

Near Berry Creek Dr, Georgetown, TX 78628
Nathaniel B.

Nathaniel B.

Model KUDS25SHBL1, Arrived on call for unit intermittently not completing cycles, found that unit stopping cycles was due to power connection under dishwasher had wrong size wire nuts wires backed out, installed correct size wire nuts, also half of the cycles do not work on console assem., will need to order black console assem. And will return with main control just incase needed to verify if cycles work, skyped office parts and talked to jordan and will reschedule for 5/9/18

Near Co Rd 405, Taylor, TX 76574
Nathaniel B.

Nathaniel B.

Model KUDS25SHBL1, Arrived on call for unit intermittently not completing cycles, found that unit stopping cycles was due to power connection under dishwasher had wrong size wire nuts wires backed out, installed correct size wire nuts, also half of the cycles do not work on console assem., will need to order black console assem. And will return with main control just incase needed to verify if cycles work, skyped office parts and talked to jordan and will reschedule for 5/9/18

Near Co Rd 405, Taylor, TX 76574
Mike G.

Mike G.

WDT720PADM2, Arrived on site for unit not cleaning checked unit and found that the customer has a water softener in the home and customer is put soap as if they do not has a water softener and unit is Creating too much Suds and not washing properly flushed unit out and customer is going to run cleaner in unit checked unit for water leaks and no leaks found at time of srv... unit checked fine at this time....

Near Bowline Dr, Georgetown, TX 78633
Mike G.

Mike G.

WDT720PADM2, Arrived on site for unit not cleaning checked unit and found that the customer has a water softener in the home and customer is put soap as if they do not has a water softener and unit is Creating too much Suds and not washing properly flushed unit out and customer is going to run cleaner in unit checked unit for water leaks and no leaks found at time of srv... unit checked fine at this time....

Near Bowline Dr, Georgetown, TX 78633
Mike C.

Mike C.

Whirlpool oven RBD305PRS00 Arrived and installed new oven control and user interface. Checked operation and unit checks good.

Near Folsom Cove, Round Rock, TX 78681
Dona W.

Dona W.

Arrived on site for too high of temperatures found, timer not shutting heater down, will need to replace the thermostat and timer. Timer is-165.80 Thermostat is-96.92 Labor189.99 Total with tax490.06 Customer does not want to repair at this time. Collected 108.24 check 1095

Near Karankawa Cir, Fort Hood, TX 76544
Dona W.

Dona W.

Arrived on site for ff drawers on evap cover freezing up, defrosted unit, replaced rc therm and replaced door per previous technician, verified all functions checked good, temperatures dropping. Customer had refrigerator pulled out from wall. All water connections dry. Customer signed waiver.

Near Karankawa Cir, Fort Hood, TX 76544
Connor M.

Connor M.

WED7800XW0 whirlpool dryer Arrived on site to test unit for over heating. Found thermal cutoff sticking at times allowing unit to reach temps slightly too high. Replaced cutoff and tested unit. Unit working properly. Instruct on proper venting and fire hazard.

Near Lockwood St, San Marcos, TX 78666
Connor M.

Connor M.

WRF736SDAM13 whirlpool refrigerator Arrived on site to test unit for low ice production. Found freezer at 4f and ff section at 37f on average. Ran test mode and fiund all thermistors, fans and related components checked fine. Ice level sensor operating properly. No error codes for ice maker. Diagnosed bad heater on icemaker mold. Ordering for return. Sw approved 5/8

Near Ladybug Ln, Martindale, TX 78655
Nathaniel B.

Nathaniel B.

Model WDF520PADM7, Unit has a 1 year extended warranty through builder, Arrived on call for dishwasher door rusting, took pic and was instructed by office repair is authorized rust is covered for 1 full year from the date of purchase. Replaced door panel all checks good, call complete.

Near Methodius Dr, Hutto, TX 78634
Nathaniel B.

Nathaniel B.

Model WDF520PADM7, Unit has a 1 year extended warranty through builder, Arrived on call for dishwasher door rusting, took pic and was instructed by office repair is authorized rust is covered for 1 full year from the date of purchase. Replaced door panel all checks good, call complete.

Near Methodius Dr, Hutto, TX 78634
Lou S.

Lou S.

arrived on site to inspect oven panel coming loose. Upon inspection, I found that the unit UI is warped near the display. Also I found that the door gaskets on both the top and bottom were badly worn and flat. Office to order panel and two door gaskets. Scheduled return for 05/10/18 JA. No gas leaks detected during service.

Near Little Elm Trail, Cedar Park, TX 78613
Thomas L.

Thomas L.

Arrived on site for unit leaking water. Found restricted drain line. Replaced drain line. Water connections are all dry. Erica ran card for payment.

Near Co Rd 202, Burnet, TX 78611
Nathaniel B.

Nathaniel B.

Model WTW8900BC0, Arrived on call for water coming from under unit still, called butch and got instruction for diag. Test and found when set on heavy duty and calling for warm water cup is over running at front left due to to much water input, per whirlpool tech line to replace the log valve and the tub ring, file number 7721916671, no water leaks after repair, call complete.

Near Grand Isle Dr, Round Rock, TX 78665
Nathaniel B.

Nathaniel B.

Model WTW8900BC0, Arrived on call for water coming from under unit still, called butch and got instruction for diag. Test and found when set on heavy duty and calling for warm water cup is over running at front left due to to much water input, per whirlpool tech line to replace the log valve and the tub ring, file number 7721916671, no water leaks after repair, call complete.

Near Grand Isle Dr, Round Rock, TX 78665
Lou S.

Lou S.

arrived on site to inspect microwave door scratched/dented. I found that the microwave door on the microwave oven wall unit was badly scratched and had a small dent in it. I removed and replaced the microwave door. Job completed.

Near Axehandle Trail, Austin, TX 78717
Lou S.

Lou S.

arrived on site to inspect noisy dishwasher. Upon further inspection by placing the unit in diagnostic mode and teasing, I found that the sump motor was bad and making an unpleasant noise. I complete diagnostics and unit tested good. I removed and replaced the sump/motor and tested unit. Unit operated as designed. No water leaks observed during service.

Near Edson Ct, Leander, TX 78641
Connor M.

Connor M.

IUD8555DX4 ikea dishwasher Arrived on site to test unit for not starting. Found unit started 4 times in a row properly for me. Ran diagnostic cycle and found error code for door open. Confirmed function of door and latch. Switch tested fone aswell. Customer may have waited too long to close door after pressing start. Unit working properly, no leaks detected.

Near Davis Ln, Austin, TX 78745
Connor M.

Connor M.

WOS51EC0AS whirlpool oven Arrived on site to test unit for no display. Found display not plugged into control. Corrected issue and tested unit. Unit working properly, no leaks detected.

Near Piping Rock Trail, Austin, TX 78748
Nathaniel B.

Nathaniel B.

Model KMHS120ESS2, Arrived on call for under light will not change from brighter to dimmer settings, found mid elimination was not working, replaced control and checked operation and all checked good, call complete.

Near Joe Dimaggio Blvd, Round Rock, TX 78665
Nathaniel B.

Nathaniel B.

Model KMHS120ESS2, Arrived on call for under light will not change from brighter to dimmer settings, found mid elimination was not working, replaced control and checked operation and all checked good, call complete.

Near Joe Dimaggio Blvd, Round Rock, TX 78665
Clif L.

Clif L.

Kitchenaid dishwasher KDFE204ESS1. Arrived on site to diagnose a dishwasher with a dispenser that is not operating properly. Tested unit and found open button for dispenser lid has come unmounted causing dispenser not to close properly. Remounted open button on dispenser lid and tested unit. Found all is functioning properly at this time. No leaks were found at time of service.

Near Arcadia Ave, Austin, TX 78757
Dona W.

Dona W.

Arrived on site for dispenser coming off during spin cycle, found dispenser broken apart and would not line up with barrel any longer, new washplate came with bolt. Replaced verified spin new unit not coming off. All water connections dry. Unit checks ok.

Near Lonesome Dove Dr, Killeen, TX 76549
Nathaniel B.

Nathaniel B.

Model WFW9500TW02, Arrived on call for unit stops in mid cycle and has error code,found that error code is f27 which is a over flow condition, found that customer says error only occurs when running clean washer with tide washer cleaning packs, called whirlpool tech line and talked to garret, was instructed by whirlpool tech line that customer will not be able to use the tide cleaning packs it is to much of the cleaner for water softner system customer to switch to afresh packs which is what whirlpool recomends for these washers and even if it is on water softner,, no parts needed, file number 7721914256, call complete, onlu charged service fee of 54.11 after tax due to this is is a second appliance

Near Stadler Cove, Round Rock, TX 78664
Nathaniel B.

Nathaniel B.

Model WFW9500TW02, Arrived on call for unit stops in mid cycle and has error code,found that error code is f27 which is a over flow condition, found that customer says error only occurs when running clean washer with tide washer cleaning packs, called whirlpool tech line and talked to garret, was instructed by whirlpool tech line that customer will not be able to use the tide cleaning packs it is to much of the cleaner for water softner system customer to switch to afresh packs which is what whirlpool recomends for these washers and even if it is on water softner,, no parts needed, file number 7721914256, call complete, onlu charged service fee of 54.11 after tax due to this is is a second appliance

Near Stadler Cove, Round Rock, TX 78664
Nathaniel B.

Nathaniel B.

Model WED9500TW3, Arrived on call for f70 error code which is no communication between main control and ui, found connections between ui and main control are good, will need main control replaced, main control 220.03, svc/labor dr300 179.99 which =400.02 plus tax 33.00 which = 433.02, customer agreed to est., installed main control and tested and all checks good, call complete., collected full balance of 433.02.

Near Stadler Cove, Round Rock, TX 78664
Nathaniel B.

Nathaniel B.

Model WED9500TW3, Arrived on call for f70 error code which is no communication between main control and ui, found connections between ui and main control are good, will need main control replaced, main control 220.03, svc/labor dr300 179.99 which =400.02 plus tax 33.00 which = 433.02, customer agreed to est., installed main control and tested and all checks good, call complete., collected full balance of 433.02.

Near Stadler Cove, Round Rock, TX 78664
Luis M.

Luis M.

Refrigerator-replaced freezer led

Near La Siesta Bend, Austin, TX 78749
Thomas L.

Thomas L.

Removed and replaced very Noisey fan motor.

Near Elkhorn Dr, Kingsland, TX 78639
Lou S.

Lou S.

arrived on site to inspect dishwasher not operating correctly. I placed the unit in diagnostic mode and unit operated as designed. I found a large amount of soap debris in the unit and error code 10/1. I found that the dispenser lid did not open during diagnostic mode. I ran the unit in regular wash mode and found that the unit would start then stop and return to the beginning of the wash cycle and shut off. Office to order dispenser and I will return with all pre diagnosed parts. Office schedule return service for 05/08/18. No leaks observed during service.

Near Honeybee Ln, Leander, TX 78641
Dona W.

Dona W.

Arrived on site for lid not locking, replaced lid lock and strike, verified unit is locking. Ran through cycle with clothing. Unit is running to spec. All water connections dry.

Near Chisholm Trail, Salado, TX 76571
Brandon C.

Brandon C.

Arrived on site for UIB timer not functioning properly, found bad control board, I replaced UIB, unit tested good.

Near Rivercrest Dr, Austin, TX 78746
Connor M.

Connor M.

WTW7800XL0 whirlpool washer Arrived on site to test unit for loud noise during operation and oil on ground. Also lid is cracking when lifted. Fiund failed tub seal allowing water into bearing assy. Bearings have failed causing loud operation. Left hinge is rusted out and needs to be replaced. Need autho. Allow 2 hours. Office to schedule directly.

Near Haven Point Loop, New Braunfels, TX 78132
Lou S.

Lou S.

arrived on site to inspect dishwasher not drying. I placed the unit in diagnostic mode and received no error codes. Continued with diagnostics and unit operated as designed with no error codes at the end. Customer advised that the rinse aid was not dispensing and last filled about two months ago. I verified the setting which was at max. I found a large amount of detergent in the unit after diagnostics. Advised the customer to cut back on detergent use using liquid and not the pods. Also advised customer to run their tap water until it got extremely hot then turn the unit on so that it would operate with hot water and not have to heat the water while cycling. I removed and replaced the dispenser and ran the unit through diagnostics again and the unit operates as designed. No water leaks observed during service.

Near Ronald Reagan Blvd, Liberty Hill, TX 78642
Thomas L.

Thomas L.

Arrived on site to assist with removing unit from wall to replaced failed parts.

Near 4 Oaks Ln, Marble Falls, TX 78654
Luis M.

Luis M.

Refrigerator-installed updated drain tube kit

Near Nelray Blvd, Austin, TX 78751
Dona W.

Dona W.

Arrived on site for low ice production and ice build up in freezer. Found freezer door seal needs replaced. Found ice maker Shute arm in freezer was up, unit is now producing ice. Found high temps in fridge ice is building up behind drawer. Will need to replace rc therm. May need evap motor in freezer as customer stating noise. Customer is going to defrost unit, has signed waiver. Sarah assisted with parts. Office will reschedule. All water connections dry.

Near S 31st St, Temple, TX 76502
Lou S.

Lou S.

arrived on site to inspect cooktop no working. Upon further inspection, I found the right back burner switch not turning; the left front Ignitor not working. The customer advised that the unit shot flames from under the knobs and looking at the manifold you can see the burn marks where it arced causing the flame. I verified all gas connections and none were leaking. Office to order right rear orafice assembly, left from orafice assembly, manifold assembly and 8 screws. Scheduled return service for 05/10/18. No leaks detected during service.

Near Ranch Rd 2243, Georgetown, TX 78628
Nathaniel B.

Nathaniel B.

Model WRX988SIBM01, Arrived on call for fridge dripping from inner top of fresh food section and a shelf is missing, found unit is missing left fresh food door bin and one mid shelf in fresh food section which per office missing parts are not covered, also for water dripping in fresh food section found ice forming at back wall at adapter , will need to order new white adapter kit, and will also need ui due to missing segments, and for rattle noise will need condenser fan motor due to noise is not normal, condenser fan motor , and blade, Skyped office parts and talked to jordan and will reschedule for 5/8/18

Near Quicksilver Cir, Round Rock, TX 78665
Nathaniel B.

Nathaniel B.

Model WRX988SIBM01, Arrived on call for fridge dripping from inner top of fresh food section and a shelf is missing, found unit is missing left fresh food door bin and one mid shelf in fresh food section which per office missing parts are not covered, also for water dripping in fresh food section found ice forming at back wall at adapter , will need to order new white adapter kit, and will also need ui due to missing segments, and for rattle noise will need condenser fan motor due to noise is not normal, condenser fan motor , and blade, Skyped office parts and talked to jordan and will reschedule for 5/8/18

Near Quicksilver Cir, Round Rock, TX 78665
Dona W.

Dona W.

Kathy-7721909843, found wiring from factory is incorrect, not able to find wire harness, unit is non repairable due to wiring. Sarah assisted. House is unoccupied. Builder has been made aware.

Near Cozy Creek Dr, Temple, TX 76502
Connor M.

Connor M.

MEDE400XW0 maytag dryer Arrived on site to test unit for shutting off after two minutes and burning smell. Found when unit shut off customer had 1 towel in a sensor cycle. This small of a load will not register on moisture sensor causing the unit to shut off thinking the items are dry. Fiund lint build up in unit from poor ventilation in back of unit. Removed excess lint and debris. Instruct customer on having ducts cleaned and potential fire hazard.

Near Teasley, Kyle, TX 78640
Connor M.

Connor M.

WED4815EW1 whirlpool dryer Arrived on site to install parts for repair. Installed drum, idler pulley, and roller kit. Confirmed unit no longer squeaking. Unit does start to rattle a little when heated up but i was unable to locate issue. Sometimes these noises go away after use. Instruct customer on waiting a month to see if it improves. If customer calls back techline will need to be contacted.

Near Teasley, Kyle, TX 78640
Lou S.

Lou S.

arrived on site to inspect ice machine not working. Upon further inspection, I disconnected the water sensor and turned the unit on. The unit began to operate and dispense water. I noticed that the wiring harness was badly oxidized and the connection to the pump was oxidized also. I also noticed that the large water hose going into the reservoir was cracked. Office to order water pump assembly, hose, water level sensor, and wiring harness. Scheduled return service for 05/09/18 JA. No water leaks observed during service.

Near Archipelago Trail, Austin, TX 78717
Dona W.

Dona W.

Arrived on site for no operation, checked household power is good, removed top panel to check control and found pressure hose loose on control was not sensing water level and was forcing drain. Reseated pressure hose and filled unit with water and clothing, unit is filling and washing. No abnormal noises, unit is running to specifications. All water connections dry.

Near Yuma, Temple, TX 76504
Thomas L.

Thomas L.

Arrived on site for water leaking. Found tub off center due to looose rear suspension spring causing water to,splash during fill. Reconnected spring and tested. All water connections are dry.

Near E 4th St, Georgetown, TX 78626
Dona W.

Dona W.

Arrived on site for dishwasher not washing well, found water temp at faucet 113- instructed customer that water temp must be at 120 or above. Customer turned hot water heater up while tech was there. Checked all parms of wash cycle. Unit is running to mfg specifications. All water connections dry.

Near Carnation Ln, Temple, TX 76502
Connor M.

Connor M.

IBS550PWW01 ikea oven File number-7721908055 arrived on site to test unit for taking a long time to preheat. Checked all components. Sensor read slightly out of range. Replaced sensor. Still same issue. Found 215vac from red to black at terminal block. Contacted techline and confirmed this low of voltage is not enough to properly power heating elements. Instruct customer on contacting an electrician.

Near Ann and Roy Butler Hike and Bike Trail, Austin, TX 78741
Thomas L.

Thomas L.

Arrived on site for communications error. Found failed control and console. Replaced both . Recalibrated with diagnostics. Operations are normal and dry.

Near TX-29, Georgetown, TX 78626
Clif L.

Clif L.

Whirlpool front load washer WFW92HEFW0. Arrived on site to diagnose a washer giving error codes. Found dispenser actuator not connected to actuator motor. Attached actuator arm properly and tested unit. Found all is working properly at this time. No leaks were found at time of service.

Near Rippling Creek Ct, Austin, TX 78732
Dona W.

Dona W.

Arrived on site for left front burner staying on high constantly, replaced left front infinite switch, all operations checked good on all burners. Customer signed waiver for cooktop removal.

Near Old Mill Rd, Salado, TX 76571
Thomas L.

Thomas L.

Arrived on site for no spin condition. Tested unit and found no spin. Tested actuator and found it to be failed. Replaced and tested and all water connections were dry.

Near Carlson Cove, Georgetown, TX 78626
Jonathan  S.

Jonathan S.

Whirlpool washer model# LSR8433KQ0. Arrived on site to install previous diagnosed parts. Gained acce

Near Red Poppy Trail, Georgetown, TX 78633
Luis M.

Luis M.

Refrigerator-replaced diffuser remolded fresh food door seal

Near W Slaughter Ln, Austin, TX 78748
Connor M.

Connor M.

WTW5000DW1 whirlpool washer Arrived on site to test unit for not starting cycle, latch clicking. Diagnosed bad latch. Replaced and tested unit. Unit working properly, no leaks detected.

Near Old San Antonio Rd, Austin, TX 78748
Luis M.

Luis M.

Refrigerator-replaced icemaker

Near Tetbury Ln, Austin, TX 78748
Steve C.

Steve C.

Arrived on site for the unit is not heating. Tested the unit and found the heating element has no continuity. Replaced the heating element and cleaned the inside of the unit. Unit works properly and advise customer to clean air vents every six months.

Near Farhills Dr, Killeen, TX 76549
Daniel  A.

Daniel A.

WDT710PAHW0 Not cleaning dishes. Defective motor/sump. Verified voltage to component. Replaced motor/sump. Checked water inlet and drain hoses. No leaks detected

Near Hunters Creek Dr, New Braunfels, TX 78132
Daniel  A.

Daniel A.

WOS51EC0AS04 Oven not heating/coming on. Replaced thermal fuse. Verified blower operation/venting. Replaced hi limit thermostat. Verified normal operation after service

Near Hunters Creek Dr, New Braunfels, TX 78132
Dona W.

Dona W.

Arrived on site for unit not running due to door not showing as closed, replaced interlock and all 3 switches, verified operations after replacing. All components checked good. Verified heating. All checks good.

Near Vintage Way, Harker Heights, TX 76548
Brandon C.

Brandon C.

Arrived on site for dishwasher wheels broken on bottom rack and leaking from handle. I replaced all wheels and tub gasket, unit tested good.

Near Lohmans Crossing Rd, Lakeway, TX 78734
Connor M.

Connor M.

KRMF706EBS01 kitchenaid refrigerator Arrived on site to install parts for repair. Installed deli door and deli control. All functions accounted for. Unit working properly at time of service. No leaks detected.

Near Silkgrass Bend, Austin, TX 78748
Connor M.

Connor M.

WTW4816FW1 whirlpool washer Arrived on site to test unit for shaking during wash and not completeing cycle. Found customer washing throw rugs. This model cannot accomodate such dense items and is designed for clothing and light bedding only. Error code for off balance load. No failures of machine. Instruct customer on proper use. Collected service charge via cc.

Near Linkmeadow Dr, Austin, TX 78748
Connor M.

Connor M.

WTW4816FW1 whirlpool washer Arrived on site to test unit for shaking during wash and not completeing cycle. Found customer washing throw rugs. This model cannot accomodate such dense items and is designed for clothing and light bedding only. Error code for off balance load. No failures of machine. Instruct customer on proper use. Collected service charge via cc.

Near Silk Oak Dr, Austin, TX 78748
Mike G.

Mike G.

WRX986SIHV00, Arrived on site for no lights are turning on, checked unit and found that when doors are opened LED lights will not turn on unplugged unit to reset control and plugged unit in and all LED lights are now working checked unit for water leaks and no leaks found at time of srv....

Near Gladedale Dr, Waco, TX 76712
Mike G.

Mike G.

WRX986SIHV00, Arrived on site for no lights are turning on, checked unit and found that when doors are opened LED lights will not turn on unplugged unit to reset control and plugged unit in and all LED lights are now working checked unit for water leaks and no leaks found at time of srv....

Near Gladedale Dr, Waco, TX 76712
Dona W.

Dona W.

Arrived on site for unit not running due to door not showing as closed, replaced interlock and all 3 switches, verified operations after replacing. All components checked good.

Near Old World Drive, Harker Heights, TX 76548
Thomas L.

Thomas L.

Arrived on site as washer would not spend or agitate on certain cycles. Found that the high-speed of the drive motor is defective. Low-speed works fine. Sarah assisted with motor order and return date.

Near Vivion Ln, Georgetown, TX 78626
Lou S.

Lou S.

arrived on site to inspect the lights under a microwave not working. Upon inspection, I found that the bulb housing had been shorted out. I removed and replaced the bulb housing and advised the customer of the correct light bulb to use. I inspected the control board and control is good. Unable to test the light due to customer did not have a bulb. Job completed.

Near Dexter Dr, Leander, TX 78641
Nathaniel B.

Nathaniel B.

Model WRF992FIFM00, Arrived on call for filter will not rotate the full 90 degrees to lock in, found defect in filter housing not allowing it to lock in properly, replaced filter housing and tested and all checks good filter housing 91.85, svc/labor rf270 169.99 which =261.84 plus tax 21.60 which =283.44, customer agreed to est. , also found ice in drain and evap sensor was in correct position sealed around drain tube in rear compressor area and cleared ice from drain, no water leaks after repair, call complete.

Near Wakonda Ct, Pflugerville, TX 78660
Nathaniel B.

Nathaniel B.

Model WRF992FIFM00, Arrived on call for filter will not rotate the full 90 degrees to lock in, found defect in filter housing not allowing it to lock in properly, replaced filter housing and tested and all checks good filter housing 91.85, svc/labor rf270 169.99 which =261.84 plus tax 21.60 which =283.44, customer agreed to est. , also found ice in drain and evap sensor was in correct position sealed around drain tube in rear compressor area and cleared ice from drain, no water leaks after repair, call complete.

Near Wakonda Ct, Pflugerville, TX 78660
Clif L.

Clif L.

Whirlpool refrigerator GS6NBEXRL01. Arrived on site to diagnose a refrigerator that is leaking when water is dispensed. Found water line disconnected at freezer door hinge causing the leak. Was able to reconnect waterline through push fitting. Tested unit and found all is functioning properly at this time. No leaks were found after services were performed.

Near Hanging Cliff Cove, Austin, TX 78759
Brandon C.

Brandon C.

Arrived on site for dishwasher not powering on, found switch on wall was flipped off not supplying power to dishwasher, also found spring for soap dispenser was broke, flipped the switch and fixed the broken spring, tested good.

Near Cloverbrook Ct, The Hills, TX 78738
Thomas L.

Thomas L.

Arrived on site for no operation. Found power to control but not out of control. Replaced control and unit tested correctly with no leaks.

Near Wolf Ranch Parkway, Georgetown, TX 78628
Dona W.

Dona W.

Arrived on site for humming noise and low wash on top rack, found sump assembly clogged off with debris, plastic, and metal. Removed. Verified operations, all water connections dry. Sump is now clear and motor is allowing for flow, no more noise from obstructions.

Near Dorothy Jane Dr, Killeen, TX 76542
Lou S.

Lou S.

arrived on site to inspect microwave light not working. Upon further inspection, I found that the light bulb in the unit was the wrong size and had burnt out. Also, the bulb housing was burnt. I removed and replaced the bulb housing and light bulb and tested unit. Unit tested good. Job complete.

Near Halsey Dr, Leander, TX 78641
Clif L.

Clif L.

Whirlpool washer WTW4816FW1. Arrived on site to diagnose a washing machine that is not spinning properly. Tested unit and found washer out of calibration causing improper spin cycles. Calibrated washing machine through diagnostics settings and tested unit. Found all is functioning properly at this time. No water leaks were found at time of service.

Near Tyson Cove, Austin, TX 78758
Kevin B.

Kevin B.

Arrived on site and found no ice production, ran test 57 and icemaker motorDidn’t cycle. Replaced ice maker and ran test 57 again and it is now cycling properly. Ran test 45 and icemaker filled with water. Requested that customer discard first batch of ice. No water leaks from connections at time of service, job complete.

Near Dusty Canyon, San Antonio, TX 78259
Steve C.

Steve C.

Arrived on site for the unit is tripping the breaker. Found the wires in the junction box wire nuts melted and shorted. Cut the burnt sections off and re wired the junction box. Tested the unit and unit is working properly. All water connections were dry at the time of service.

Near Littlerock Dr, Killeen, TX 76549
Thomas L.

Thomas L.

Install door ropes supplied by customer. All water connections were dry.

Near Silverstone Dr, Georgetown, TX 78633
Lou S.

Lou S.

arrived on site to inspect ice maker not working. Customer advised that a few days before today's service, there was a power failure and when they checked the refrigerator the ice maker was working again. I inspected the unit and placed unit in diagnostics. The unit is working as designed and is making ice. I found an abundance of moisture in the rc, on the front of the ice maker and on the opening of the ice bin. Also found large gapping between the rc cabinet and chassis. I used manufacturer approved clear silicone to seal the gapping. Also found that the drain tube in the back of the unit had approximately 1/8 inch gapping between it and the chassis which could be a potential frost buildup inside the rc. I used manufacturer approved white silicone to seal the gap. No water leaks observed during service.

Near Sandbur Lane, Leander, TX 78641
Dona W.

Dona W.

Arrived on site for no operation, found customer has an open ground and water was off to the unit. Washer had been taken outside and moved back inside. Refrigerator was where washer is now located, customer stated that she was shocked by refrigerator that is why Appliance was moved. Spoke to landlord to let him know that customer instruct are not covered. Stated that he did not dispatch us to come out so he would not pay today. All water connections dry. Jordan has added notes.

Near E Valley Rd, Harker Heights, TX 76548
Luis M.

Luis M.

Ice machine. Replaced failed water valve and bin thermistor

Near Beverly Rd, Austin, TX 78703
Dona W.

Dona W.

Arrived on site for sensor dry not drying. Unit would not advance with control for more than 2 minutes. Found sensor wire off of moisture sensor, not allowing for electrode to adjust per moisture. Verified operations after attaching wiring. Air flow good, temps checked good.

Near Richland Dr, Belton, TX 76513
Thomas L.

Thomas L.

Arrived on site or no ice conditions and a torn door gasket. Found open water valve contacts in icemaker and right door gasket torn. Replace both. Water connections were dry.

Near Piedmont Ln, Georgetown, TX 78633
Connor M.

Connor M.

WEE745H0FS0 whirlpool range Arrived on site to test unit for not regulating temps on rr burner. Found switch faulty. Replaced and tested unit. Unit working properly at time of service.

Near River Chase Dr, New Braunfels, TX 78132
Joseph C.

Joseph C.

KRFC302ESS00 Arrived on site for “mullion not seating properly into closing pocket correctly” complaint. Adjusted mullion .25” upward. Left door is now closing properly. No leaks detected, at time of service.

Near Austex Acres Ln, Manor, TX 78653
Dona W.

Dona W.

Found electronic control not shutting down, will need electronic control will need to be replaced/ 126.06 and 137.16/ labor 179.99. Customer does not want to repair at this time. Venting clear. Customer paid by card for 2nd Appliance 54.11.

Near Allena Ln, Temple, TX 76502
Dona W.

Dona W.

Damper-133.77/ RC therm-56.03/ evap cover-151.99/ support-30.49. Arrived on site for loud noise in fridge, found evaporator completely iced over, found damper motor not opening, will need new damper and evaporator motor And cover customer does not want to fix At this time. Paid 108.24 for diagnosis. All water connections dry.

Near Allena Ln, Temple, TX 76502
Dona W.

Dona W.

Arrived on site for no ice production, found ice maker motor stalled would not call for water. Found where auger arm inserts unit is stuck. Replaced ice maker, unit called for water but no water incoming on two way valve, will need valve. All water connections dry, customer pulled refrigerator in and out. Jordan assisted with reschedule and part. Unit is under warranty was purchased in sept 2017.

Near Allena Ln, Temple, TX 76502
Joseph C.

Joseph C.

KDTE104ESS4 dishwasher Arrived on site for “washer will not complete cycles” complaint. Inspected unit and found sump/motor had burned out control. Removed and replaced sump/motor and control. Tested unit. Unit is performing as designed. No leaks detected, at time of service.

Near Simond Ave, Austin, TX 78723
Connor M.

Connor M.

MVWX655DW1 maytag washer TL210-169.99 arrived on site to test unit for making noise and not completing cycle. Found tub full of water. Firced drian and spin only to get a loud noise and no drian movment. Removed water form tub and accessed drain pump. Found debris in drian pump not allowing it to move water. Removed and tested unit. Unit working properly. Ran calibration and instructed on proper use and care. No leaks detected at time of service. Collected funds via cc.

Near Auburn Blaze Ln, Austin, TX 78744
Joseph C.

Joseph C.

WMH31017FB0 Arrived on site for “making noise when in operation” complaint. Inspected unit and found sealing tape in blower blades. Removed tape and tested unit. Unit is performing as designed.

Near Nitschke St, Austin, TX 78723
Lou S.

Lou S.

arrived on site to install previously diagnosed and ordered parts. Removed and replaced the TOD, blower, and both upper and lower door gaskets. Tested unit and unit tested good.

Near Westinghouse Dr, Round Rock, TX 78681
Connor M.

Connor M.

RTW4516FW2 roper washer File number-7721899570 arrived on site to test unti for not starting cycle. Fiund lock led flashing and non responsive. Cycled power at outlet unit working fine. Found neutral at wall getting 120 v. This is causing interference with control. Calibrated and instruct on contacting an electrician. Documented call with techline. No leaks detected.

Near Turtle Dove Dr, Austin, TX 78744
Thomas L.

Thomas L.

Arrived on site or no cool condition. Both compartments were at 68°. Compressor was not running. Inspected compressor area and found that they start device had come off the compressor. Reinstalled the compressor started correctly. All operations are normal. Customer will need to allow approximately 12 hours to reach maximum temperature.

Near Wildflower Blvd, Marble Falls, TX 78654
Daniel  A.

Daniel A.

MEDB765FW0 Dryer not coming on. Touch to start button not responding. Instruct Cust on cycle selection touch button response activation does not need to be pressed with excessive pressure. Instruct customer on venting:/fire hazard. Normal operation after service

Near Deer Cross Ln, San Antonio, TX 78260
Luis M.

Luis M.

Refrigerator-installed drawers to correct location on in channel. Added foam gasket under door seal per manuf.

Near Parkrose Drive, Buda, TX 78610
Joseph C.

Joseph C.

WTW8500DR0 washer Arrived on site for “dr error/not draining” complaint. Inspected unit and found drain pump burned out. Removed and replaced drain pump. Tested unit. Unit is performing as designed. No leaks detected, at time of service.

Near Jacqueline Ln, Austin, TX 78724
Nathaniel B.

Nathaniel B.

Model WED8300SW2, Arrived on call for f01 error which is main control failure, replaced main control and tested and all checks good, call complete, collected remaining balance of 332.36, call complete. Found dryer wall vent is restricted, customer to call dryer vent cleaning service and not to run dryer until wall vent is cleared due to this is a fire hazzard. Call complete.

Near Justeford Dr, Pflugerville, TX 78660
Nathaniel B.

Nathaniel B.

Model WED8300SW2, Arrived on call for f01 error which is main control failure, replaced main control and tested and all checks good, call complete, collected remaining balance of 332.36, call complete. Found dryer wall vent is restricted, customer to call dryer vent cleaning service and not to run dryer until wall vent is cleared due to this is a fire hazzard. Call complete.

Near Justeford Dr, Pflugerville, TX 78660
Mike G.

Mike G.

JJW3430WP00, Arrived on site for F2E0 ERROR CODE-WILL HEAT THEN GETS THE ERROR CODE ONCE IT REACHES TEMP, checked unit and found that the UI control panel is bad replaced control panel with UI checked unit and found that the unit is now working properly and is heating unit checked fine at this time.....

Near Chiswick High Dr, Woodway, TX 76712
Mike G.

Mike G.

JJW3430WP00, Arrived on site for F2E0 ERROR CODE-WILL HEAT THEN GETS THE ERROR CODE ONCE IT REACHES TEMP, checked unit and found that the UI control panel is bad replaced control panel with UI checked unit and found that the unit is now working properly and is heating unit checked fine at this time.....

Near Chiswick High Dr, Woodway, TX 76712
Luis M.

Luis M.

Refrigerator-installed new icemaker assembly

Near Parkrose Drive, Buda, TX 78610
Connor M.

Connor M.

MGR6775ADW maytag oven Installed ignitor for not baking. Unit now baking properly. Job complete.

Near Stage Coach Trail, Austin, TX 78745
Lou S.

Lou S.

arrived on site to install previously diagnosed and ordered parts. Removed and replaced the emitter and receiver and tested unit. Unit tested good. No water leaks observed during service.

Near N Frontier Ln, Cedar Park, TX 78613
Clif L.

Clif L.

IKEA dishwasher IUD8555DX1. Arrived on site to replace previously ordered parts for dishwasher. Rediagnosed unit prior to replacing parts and found 8-4 drain error saved in control. Removed drain pump and found broken glass in pump assembly which has damaged pump impeller. Also noted after replacing pump OWI sensor was not registering water level properly. Replaced sensor and tested unit. Found all is now functioning properly and no leaks were found after services were performed.

Near Blue Jay Dr, Lakeway, TX 78734
Brandon C.

Brandon C.

Arrived on site for part hanger, I replaced timer, unit tested good.

Near Whitetail Ridge, Dripping Springs, TX 78620
Brandon C.

Brandon C.

Arrived on site for part hanger, I replaced broken strike, unit tested good.

Near Whitetail Ridge, Dripping Springs, TX 78620
Connor M.

Connor M.

WDF520PADM7 whirlpool dishwasher Arrived on site to test unit for leaving residue on dishes. Found rinse aid dispenser not working. Replaced dispenser and tested unit. Unit working properly. Instruct on proper use and care. No leaks detected

Near Sendera Mesa Dr, Austin, TX 78749
Mike G.

Mike G.

MVWC415EW1, Arrived on site to install new control checked unit after repair and unit is now filling and washing and draining and spining and lid is locking and unlocking checked unit for water leaks and no leaks found at time of srv.... unit checked fine at this time....

Near N 12th St, Waco, TX 76707
Mike G.

Mike G.

MVWC415EW1, Arrived on site to install new control checked unit after repair and unit is now filling and washing and draining and spining and lid is locking and unlocking checked unit for water leaks and no leaks found at time of srv.... unit checked fine at this time....

Near N 12th St, Waco, TX 76707
Lou S.

Lou S.

arrived on site to inspect dishwasher leaking. Upon further inspection, i found that the manifold was not attaching correctly to the feed tube causing a large amount of water to shoot out of it which was causing the leak. I found that the right rack arm was hanging in the back. I removed the upper rack and adjusted the rack arm and reinstalled the upper rack. The manifold attached to the feed tube as designed. I tested the unit and the unit operated as designed. No leaks observed during service.

Near Pinot Noir St, Leander, TX 78641
Thomas L.

Thomas L.

Arrived on site for no drain condition. Found unit to have failed drain hose check and a failed drain pump. Replace both. Unit tested properly with no leaks.

Near Alexis Ln, Horseshoe Bay, TX 78657
Brandon C.

Brandon C.

Arrived on site for f2e2 dishwasher error code, found faulty UIB, I replaced UIB, unit tested good.

Near DS Ranch Rd, Dripping Springs, TX 78620
Clif L.

Clif L.

Kitchenaid dishwasher KUDS03STSS3. Arrived on site to diagnose a dishwasher that is making abnormal noises when running. Tested unit and found debris clogging screen and circulation pump causing abnormal noise. Removed all debris from pump and tested unit. Found noises are greatly reduced at this time and no parts appear to need to be replaced. Quoted homeowner on pump replacement for reference, And advised quote is good for 90 days. No the repairs appear to be needed at this time and all is functioning properly. No water leaks found at time of service.

Near Montclair Bend, Austin, TX 78732
Connor M.

Connor M.

WFW92HEFC0 whirlpool washer Arrived on site to install parts for return. Removed cm and lever and found diverter moving freely. Dispenser checked fine. Replaced dispenser motor, cam and lever. Ran through step diagnostic cycle. Unit working properly at time of service. No leaks detected.

Near Canon Wren Dr, Austin, TX 78746
Mike G.

Mike G.

WRF736SDAM11, Arrived on site to install new evap fan motor and blade and r&l pan stops checked unit after repair and unit is starting to cool and is not making noise at time of srv... checked unit for water leaks and no leaks found at time of srv... unit checked fine at this time....

Near Kim Ln, Robinson, TX 76706
Mike G.

Mike G.

WRF736SDAM11, Arrived on site to install new evap fan motor and blade and r&l pan stops checked unit after repair and unit is starting to cool and is not making noise at time of srv... checked unit for water leaks and no leaks found at time of srv... unit checked fine at this time....

Near Kim Ln, Robinson, TX 76706
Daniel  A.

Daniel A.

RTW4516FW Washer not starting when start button activated. Verified voltage and cyclecselection. Corrected door strike position to activate door latch. Verified normal operation after. Checked water inlet and drain hoses. No leaks detected

Near Deer Run Pass, Canyon Lake, TX 78133
Dona W.

Dona W.

Arrived on site for left door not closing correctly found middle seal hinge off of upper track, removed and reseated, verified operations unit checks good. All water connections dry.

Near County Rd 271, Kempner, TX 76539
Brandon C.

Brandon C.

Arrived on site for microwave not heating and showing f7 error code, found a faulty inverter board and magnetron. We replaced both parts, unit tested good.

Near Cinca Terra Dr, Austin, TX 78738
Lou S.

Lou S.

arrived on site to inspect wash arm melted in element. Upon further inspection, I found that the lower wash arm had come off and fallen onto the heating element and melted it in two places. I removed and replaced the lower wash arm and tested unit. The unit operated as designed. No water leaks observed during service.

Near Ridgewood Dr, Leander, TX 78641
Kevin B.

Kevin B.

Arrived on site and inspected unit and found some residual frost inside of freezer But most of it has already dissipated. Customer has also cleared food from freezer and the issue was likely a food item holding the door slightly open. Freezer is now cooling properly and no further repair is required at this time, requested that customer continue to monitor freezer for correct operation. Job complete.

Near Copperhurst, Converse, TX 78109
Mike G.

Mike G.

WDT780SAEM1, Arrived on site to install new OWI sensor checked after repair by running test cycle unit filled washed and drained and element is heating checked unit for water leaks and no leaks found at time of srv... unit checked fine at this time....

Near Buckingham Pl, Hewitt, TX 76643
Mike G.

Mike G.

WDT780SAEM1, Arrived on site to install new OWI sensor checked after repair by running test cycle unit filled washed and drained and element is heating checked unit for water leaks and no leaks found at time of srv... unit checked fine at this time....

Near Buckingham Pl, Hewitt, TX 76643
Dona W.

Dona W.

Arrived on site for unit not spinning leaving clothes very wet, found shifter error, replace shift actuator, re calibrated unit checked good. Verified all water connections dry. Cycle completed. Collected 284.22 on card

Near Unnamed Road, Briggs, TX 78608
Mike C.

Mike C.

Whirlpool Refrigerator ET1CHMXKB03 Arrived and installed defrost heater clip from heater to drip pan hole. Installed new air tower to evaporator cover. Checked operation and unit checks good.

Near Chris Kelley Boulevard, Hutto, TX 78634
Diego G.

Diego G.

Arrived on site. Check for no operation issues. Found blower seized up. Replace blower and fuse. Tested unit, all functions tested OK. Job complete

Near Magnum, New Braunfels, TX 78132
Lou S.

Lou S.

Near Ronald Reagan Blvd, Leander, TX 78641
Connor M.

Connor M.

WED85HEFC0 whirlpool dryer Arrived on site to test unit for issue with dryer duct coming from unit. Found duct loose internally. Corrected issue and tested unit. Unit working properly. Instruct on proper venting and fire hazard.

Near Shoal Creek Trail, Austin, TX
Thomas L.

Thomas L.

Arrived on site for no ice condition. Found temp 3 degrees in freezer. Water to unit. Emitter flashing double flashes. Emitter/receiver failed. No internet/phone connection. Office to reschedule. I am taking prescreened parts back with me just Incase they are needed but I don’t think they will be needed.

Near Riverside View, Kingsland, TX 78639
Clif L.

Clif L.

Whirlpool range WFG540H0ES0. Arrived on site to diagnose and oven that is not heating properly. Tested unit and found temperature average is 20° lower than setpoint. Set calibration settings to compensate for temperature offset. Tested unit and found all is not working properly. No gas leaks were found at time of service. Also advised homeowner on operation of dial type thermometers and extended time needed for thermometer preheat to ensure accurate readings.

Near Winecup Way, Georgetown, TX 78633
Connor M.

Connor M.

WDF320PADS2 whirlpool dishwasher Arrived on site to test unit for not washing dishes. Found when sump is given power it would not come on. Confirmed bad sump. Replaced and tested unit. Unit working properly, no leaks detected.

Near San Gabriel St, Austin, TX 78705
Dona W.

Dona W.

Arrived on site for unit grinding heavily on agitate cycle, found seized transmission on agitate side, replaced transmission, and cam pulley. Verified operations, no abnormal noises, unit checks good. All water connections dry.

Near Jake Spoon Dr, Killeen, TX 76549
Dona W.

Dona W.

Arrived on site for washer starting cycles on its own once load has finished will restart a cycle. Replaced control verified fill, agitate, drain and spin. All water connections dry. Unit shut off, and did not start another cycle. Hose in standpipe secure and at correct level. Spoke with Selina did not need authorization.

Near Jake Spoon Dr, Killeen, TX 76549
Mike C.

Mike C.

Whirlpool dishwasher WDF520PADM7 Arrived to check unit for a water leak. Started a automatic diagnostics cycle and found water dripping in the front left middle of door. Removed outer door panel and found water leak coming from the vent assembly. Removed vent assembly and found gasket folded over and not seated into channel. Installed vent gasket into channel and reassembled vent assembly. Checked for any leaks and none were found.

Near Cyril Dr, Hutto, TX 78634
Jerry C.

Jerry C.

WMH32519FS0 Arrived to inspect no heat. I found the heating system failed and require the magnetron, capacitor and diode. I removed and replaced the components and re-installed the unit. Operational test good.

Near Sierra Mar Loop, Leander, TX 78641
Clif L.

Clif L.

Whirlpool dishwasher WDT720PADM2. Arrived on site to replace direction pads for dishwasher hinges. Replaced both friction pads and tested unit. Found all is functioning properly at this time. No leaks were found at time of service.

Near Davis Mountain Cir, Georgetown, TX 78633
Connor M.

Connor M.

MVWC200XW1 maytag washer Arrived on site to install parts for not completeing cycle. Installed actuator and capacitor. Ran test cycle, all functions accounted for. Unit working properly at time of service. No leaks detected.

Near W 35th St, Austin, TX 78705
Nathaniel B.

Nathaniel B.

Model MEDB835DW3, Arrived on call for belt and rollers are bad, replaced rollers prior, returned with correct dryer belt today and installed it and functions of the dryer check good, customer paid full balance prior, checked dryer vent and it is restricted, customer not to use the dryer until wall vent is cleared due to this is a fire hazzard, call complete.

Near Pearson Way, Round Rock, TX 78665
Nathaniel B.

Nathaniel B.

Model MEDB835DW3, Arrived on call for belt and rollers are bad, replaced rollers prior, returned with correct dryer belt today and installed it and functions of the dryer check good, customer paid full balance prior, checked dryer vent and it is restricted, customer not to use the dryer until wall vent is cleared due to this is a fire hazzard, call complete.

Near Pearson Way, Round Rock, TX 78665
Thomas L.

Thomas L.

Arrived on site for no heat condition. Unit has defective TOD

Near TX-29, Liberty Hill, TX 78642
Joseph C.

Joseph C.

KDTM404ESS2 Arrived on site for “no power to unit” complaint. Inspected unit and found loose power connection, at control. Reconnected plug. Tested unit. Unit is performing as designed. No leaks detected, at time of service. Customer did not have closing paperwork, but will send to office.

Near Sacramento Dr, Austin, TX 78704
Thomas L.

Thomas L.

Replaced cracked fresh food evaporator cover. Replaced left door as it was causing an air leak. Water connections were all dry.

Near Casa Verde Dr, Georgetown, TX 78633
Mike G.

Mike G.

WEE510S0FS1, Arrived on site for Control panel Finishing coming off, checked unit and found that the control panel finishing hes peeled off replaced control panel checked unit after repair and unit checked fine at this time....

Near Red Rock Dr, Belton, TX 76513
Mike G.

Mike G.

WEE510S0FS1, Arrived on site for Control panel Finishing coming off, checked unit and found that the control panel finishing hes peeled off replaced control panel checked unit after repair and unit checked fine at this time....

Near Red Rock Dr, Belton, TX 76513
Luis M.

Luis M.

Refrigerator-replaced loud diffuser adjusted front legs on cabinet

Near Vista Village Cove, Austin, TX 78738
Joseph C.

Joseph C.

KRFF707ESS01 Arrived on site for “hinge cover off” complaint. Inspected unit and found hinge cover not installed correctly. Installed cover per spec. Unit is performing as designed. No leaks detected at time of service.

Near Wathen Ave, Austin, TX 78703
Connor M.

Connor M.

WDF330PAHB whirlpool dishwasher Arrived on site to install panel for cosmetic damage. Installed and tested unit. Unit working properly, no leaks detected.

Near Tailwind Dr, Kyle, TX 78640
Clif L.

Clif L.

Whirlpool washer WFW9550WW00. Arrived on site to diagnose a washer that is not completing cycles. Tested unit and found very low water flow through cold and hot solenoids of inlet valve. Replaced inlet valve and tested unit. Found all is functioning properly at this time. No other repairs are needed and no leaks found after services were performed.

Near Plumewood Dr, Austin, TX 78750
Joseph C.

Joseph C.

KUDC10FXSS4 Arrived on site for “burned out control and harness” complaint. Inspected unit and found control and harness burned out. Removed and replaced harness and control. Tested unit. Unit is performing as designed. No leaks detected, at time of service.

Near W 31st St, Austin, TX 78705
Mike C.

Mike C.

Maytag Dryer MEDB725BW0 Arrived to install new thermal fuse and wire connector spade. Checked operation and unit checks good.

Near Desert Willow Cove, Round Rock, TX 78681
Connor M.

Connor M.

WED4815EW1 whirlpool dryer Arrived on site to install start switch. Installed and tested unit. Unit working properly. Instruct on proper venting and potential fire hazard.

Near Red Pebble Rd, Austin, TX 78739
Thomas L.

Thomas L.

Arrived on site for vibration during spin. It appears that the basket is out of round. I am bringing the gearcase and rotor just in case. Erica assisted. We can do this Thursday but customer is requesting next Tuesday. Erica

Near Co Rd 262, Georgetown, TX 78633
Dona W.

Dona W.

Arrived on site for fridge not getting below 55 degrees, found unit completely frozen off in fresh food section, customer de frosted unit. Replaced rc evap,cover that contains new therm wiring and fan. Found ff evap motor was not turning due to no voltage from control. Replaced control. Verified all components working after replacement, verified all water connections dry. Temperatures dropping, customer signed waiver.

Near Province Point, Harker Heights, TX 76548
Lou S.

Lou S.

arrived on site to install previously diagnosed part. Removed and replaced the display control. Tested unit and unit operated as designed. Job completed.

Near Wild Sage Lane, Liberty Hill, TX 78642
Connor M.

Connor M.

KUIC15PHZS0 kitchenaid ice machine Arrived on site to install parts for repair. Unit not starting cycle unitl bin thermistor was replaced. Found harness and water level sensor corroded. Replaced both. unit working properly at time of service. No leaks detected.

Near Medicine Creek Dr, Austin, TX 78735
Mike G.

Mike G.

WOS51EC0AS04, Arrived on site for unit getting to hot, checked unit and found that unit was set on c* and no f* reset unit to f* and checked unit temps at 350* and 1st hi temp 407* and low temp 332* = 369*, 2nd hi temp 389* and low temp 338* = 368* 3rd hi temp 396* and low temp 339* = 367* recalibrated unit to a -10 checked unit checked fine at this time...

Near Redondo Dr, Waco, TX 76712
Mike G.

Mike G.

WOS51EC0AS04, Arrived on site for unit getting to hot, checked unit and found that unit was set on c* and no f* reset unit to f* and checked unit temps at 350* and 1st hi temp 407* and low temp 332* = 369*, 2nd hi temp 389* and low temp 338* = 368* 3rd hi temp 396* and low temp 339* = 367* recalibrated unit to a -10 checked unit checked fine at this time...

Near Redondo Dr, Waco, TX 76712
Luis M.

Luis M.

Refrigerator-replaced fresh food and freezer door

Near N Bluff Dr, Austin, TX 78745
Connor M.

Connor M.

WMH31017FS0 whirlpool microwave Arrived on site to test unit for light not coming on. Found voltage to socket but incorrect voltage. Replaced panel, still same issue. Will need control and socket for return. Ms approved thursday.

Near Rialto Blvd, Austin, TX 78735
Jonathan  S.

Jonathan S.

Whirlpool washer not draining or spinning.

Near Spanish Oak Dr, Georgetown, TX 78628
Clif L.

Clif L.

Maytag dishwasher MDB8969SDM0. Arrived on site to diagnose a dishwasher that is leaking during cycles. Tested unit and found door seal worn out due to wear and tear. Replaced door seal and tested unit. Found all is functioning properly at this time. No leaks were found after services were performed.

Near Horseback Hollow, Austin, TX 78732
Thomas L.

Thomas L.

Arrived on site or no light operation. Determined loose cam was not depressing switch properly. Corrected loose Cam and light now operates properly.

Near Palo Duro Ln, Liberty Hill, TX 78642
Connor M.

Connor M.

KSGG700ESS0 kitchenaid range Arrived on site to test unit for not baking and giving f8e0 error code indicating failed cooling fan. Confirmed bad hal sensor on fan and replaced. Unit working properly at time of service.

Near Malvern Hill Ct, Austin, TX 78745
Luis M.

Luis M.

Refrigerator-replaced Evap fan motor assembly

Near Wycombe Dr, Austin, TX 78749