Appliance Repair Spring Branch (unincorporated community) Texas
Appliance Express Rated out of 5 stars based on customer reviews
We serviced a
GE WASHER
Model GFW650SPN0SN
Near Spring Branch (unincorporated community), TX 78070
Tyler L
Job Details:
04/28/2022
"Arrived on site for complaints of smart dispenser not working. Entered service mode and tested all valves. Detergent was dispensed and water in unit became soapy with suds. Exited service mode and started a normal cycle with smart dispenser set on auto. Monitored as it advanced through the cycle and detergent was dispensed. Unit functioning as designed, no water leaks detected, job complete."
We serviced a
GE REFRIGERATOR
Model GYE22KMHHES
Near Spring Branch (unincorporated community), TX 78070
Andrew
Job Details:
04/13/2022
"Arrived on site to test unit for RC not cooling properly. Found RC evap cover covered in frost/ice. Exposed evap and found evap motor not engaging. Put unit into defrost and heating element working as designed. Replaced evap motor, tested unit, unit now working as designed. Found thermistors in range. Unit not currently connected to water.
We serviced a
GE REFRIGERATOR
Model GNE29GSKFSS
Near Spring Branch (unincorporated community), TX 78070
Andrey
Job Details:
03/21/2022
"Arrived on site to replace previously diagnosed main control board, replaced control board tested ice maker ice maker called for water but did not receive any, disconnected water line going from valve to filter activated test 58 but valve would not open just made a buzzing noise, valve receiving proper voltage, will need inlet water valve to get ice maker to work again, Office to get authorization and reschedule; ordrng 1 WR02X13684 (Filter manifold) and 1 WR57X27527 (Inlet water valve)"
We serviced a
KITCHENAID DISHWASHER
Model KDTE204ESS3
Near Spring Branch (unincorporated community), TX 78070
Andrew
Job Details:
04/28/2021
"Arrived on site to install sump and motor, lower and upper spray arms from previous diagnosis. Replaced parts, tested unit, unit works good. No leaks detected. Job complete."