Appliance Repair McQueeney Texas

Appliance Express Rated 5.0 out of 5 stars based on 5 customer reviews

We serviced a
JENN-AIR FREEZER
Model JB36NXFXRE00
Near McQueeney, TX 78123
Andrey
Job Details: 05/30/2023
"Arrived on site to test unit for not cooling, tested unit found compressor running but no refrigerant in system, exposed RC and FC evaporators and found a refrigerant leak in the fresh food evap, fixed leak and replaced dye drier, pumped system with nitrogen, pressures held perfect, pumped system down for 20 minutes, charged system with 5oz of r134a, RC and FC evaporators developed good frost patterns advising customer to monitor for 24 hours before loading, job complete"
We serviced a
WHIRLPOOL DRYER
Model WED5000DW2
Near McQueeney, TX 78123
Andrey
Job Details: 05/23/2023
"Arrived on site to test unit for scrapping noise, tested unit found front panel clips broken causing drum to move excessively in cabinet, rear drum felt gasket failed causing drum to rub against metal bulkhead damaging it, will need to replace panel clips, repair kit and drum to fix issue, ordering parts, offer to reschedule ; ordrng 2 WP98234 (Clips)s and 2 W10854425 (Clip front panel)s and 1 W10899578 (Drum)"
We serviced a
WHIRLPOOL DISHWASHER
Model WDT730PAHZ0
Near McQueeney, TX 78123
Joe Z
Job Details: 05/10/2023
"Arrived on site for broken wheel on upper rack. Upon arrival,inspected unit and is not securely mounted to cabinet. found left side wheel adjuster of upper rack has failed. Need to replace wheel adjuster and stop. Replaced adjuster kit W10712395, and 1 stop WPW10508950. Unit is operating as designed. No leaks present at this time. Job complete"
We serviced a
JENN-AIR FREEZER
Model JB36NXFXRE00
Near McQueeney, TX 78123
Andrey
Job Details: 04/19/2023
"Arrived on site to test unit for not cooling, exposed FC evaporator and found no frost pattern, checked entire system for leaks with UV light, found leak in pan heater and RC evaporator, thermistor metal clip made a hole, replaced pan heater, compressor, dye drier, access valve and RC evaporator, pumped system with nitrogen, system now has no leaks, vacuumed system down for 30 minutes, held perfect vacuum for 10 minutes, charged 5oz with R 134a, powered unit on, RC evaporator developed a good frost pattern and FC as well, unit is now running as designed, no leaks detected job complete"
We serviced a
JENN-AIR FREEZER
Model JB36NXFXRE00
Near McQueeney, TX 78123
Andrey
Job Details: 03/29/2023
"Arrived on site to perform previously diagnosed sealed system, pulled unit out to inspect foe any leaks, after checking all joints found small leak around compressor connection, replaced compressor, access valve and dye drier, pumped down system for 30min vacuum held good, charged system to 5oz of R135A refrigerant, pressures reading good, both evaporators developed good frost patterns, advised customer to put a bottle of water into FC when bottle frozen, unit will be good to load, no leaks detected job complete"
McQueeney, Texas
04/20/2023
Overall Experience
Thomas
McQueeney, Texas
01/21/2021
Noah is very knowledgable and can listen and explain!
Overall Experience
Ruth
McQueeney, Texas
02/15/2019
good service
Overall Experience
Stacie Schlogel
McQueeney, Texas
10/22/2018
The technician was amazing. The company was amazing. They were very quick to get my repair done.
Overall Experience
John
McQueeney, Texas
08/06/2018
Fast took no time at all
Overall Experience