We serviced a
WHIRLPOOL REFRIGERATOR
Model WRS315SDHZ08
Near Bellmead, TX 76705
Jonathan M
Job Details: 01/11/2022
Arrived onsite for a refrigerator thats still not making ice. Inspected unit and work area. Took temperature and found the freezer at 3?F. Attempted to jump the ice maker and the unit harvested ice. I calle
We serviced a
WHIRLPOOL REFRIGERATOR
Model WRS315SDHZ08
Near Bellmead, TX 76705
Jonathan M
Job Details: 12/20/2021
Arrived on site to install previously diagnosed parts. Inspected unit and work area. Replaced icemaker and tested the unit. The unit harvested and filled as designed
We serviced a
WHIRLPOOL REFRIGERATOR
Model WRS315SDHZ08
Near Bellmead, TX 76705
Jonathan M
Job Details: 11/24/2021
"Arrived onsite for a refrigerator that is making ice slowly. Inspected unit and work area. Checked freezer temperature and found the unit at 2?F. Attempted to jump the icemaker and found the icemaker would jump, harvest and fill. I did find the ice bin half full of ice. The customer advised they maybe have used roughly 15 to 20 cubes since the icemaker was replaced. They said that the unit made ice fairly well for 2 to 3 days and then completely stopped and only made a handful of batches of ice since. I called Whirlpool Techline and spoke to Bruce SR# 7732323067. He advised that based on the current information and the temperatures being good in the freezer, the issue would have to be with the icemaker. .; ordrng 1 W11546935 (Icemaker)"
We serviced a
WHIRLPOOL RANGE
Model WGG745S0FS02
Near Bellmead, TX 76705
Jonathan M
Job Details: 11/02/2021
Arrived on site for a range that won?t heat either oven. Inspected unit and work area. Confirmed customers complaint and found the igniter is turning on but no gas being supplied. Checked voltage from the control and found proper voltage going to the igniter?s. Check the igniter?s for resistance and off showed within range. I called Whirlpool Techline and spoke to Drew SR# 7732144365. He had me check resistance he values again and tracing voltage. He advised that the resistance value on the valve was out of spec and to replace the gas valve. Check the new gas valve and check resistance on the valve. Found the same resistance rating on the valve. I called back to whirlpool Techline and spoke to Adrian (same SR#). He had me check to see if the safety check valve was turned off or on. I found that the valve is turned off which he advised would only make it to where the burners were receiving gas. Flipped it on and all the elements began to ignite and turn on as designed. Call complete.
We serviced a
WHIRLPOOL REFRIGERATOR
Model WRS315SDHZ08
Near Bellmead, TX 76705
Jonathan M
Job Details: 11/02/2021
Arrived on site to install previously diagnosed parents. Inspected unit and work area. Found the customer had a quarter of a bin full of ice. I did ask the customer if it was making ice. He did advise that it was and that it does make 3 to 4 cups for each day. I did replace the icemaker but did tell him that these icemakers are extremely slow production and will typically make anywhere from 50 to 70 cubes a day. Tested the unit and the unit harvested and filled as designed. Call complete.