Need Appliance Repair Service? Have a general question?
We love solving problems! Let us know how we can help by reaching out below.

How can we help? Do you need appliance repair?

Local Reviews
for Robinson, TX

Rated 5.0 out of 5 stars based on 8 customer reviews

Map of Robinson, TX

Great





Map of Robinson, TX

Very helpful!





Map of Robinson, TX

Kenneth




Mike was prompt, efficient, courteous, and professional. I could not have expected more for the service we requested.


Map of Robinson, TX

Great Service Mike is awesome.




Mike was very professional and did an excellent repair on our refrigerator. He was knowledgeable and explained everything to us where could understand the situation.. Would highly recommend Appliance Express and especially Mike.


Map of Robinson, TX

Great Service




Mike did a great job explaining what he was doing and why he was doing it.


Map of Robinson, TX

Mike did a great job




Thank you for being so prompt and pleasant


Map of Robinson, TX

Great job





Map of Robinson, TX

very nice man




nice man


Steve C.

Steve C.

REFRIGERATOR WHIRLPOOL WRF555SDHV00 Arrived on site for the unit has frost buildup in the freezer. Customer advised intermittently the unit will have frost buildup. Tess of the unit and found the freezer door at the bottom is warped and causing a air leak. Will need to order the freezer door black and advise customer it will take 6 to 8 weeks. All water connections were dry at the time of service. Unit is freezing and cooling properly. ; ordrng 1 W10862407 (dor-fip BLK)

Near Stallion Dr, Robinson, TX 76706
Arthur B.

Arthur B.

FREEZER WHIRLPOOL WZC3115DW00 "Arrived onsite to install dye drier and process stub to chest freezer from prior tech’s diagnosis. Removed drier. Installed new UV drier and process stub using braising methods. Vacuumed unit down to -25psi. Charged system with 4.8oz of R134a refrigerant. Powered up unit. Found inner liner started to freeze. Pressures are 2psi low side,120psi high side and holding. Did find signs of corrosion on OEM drier welds. No other issues found."

Near W Moonlight Dr, Robinson, TX 76706
Arthur B.

Arthur B.

FREEZER WHIRLPOOL WZC3115DW00 "Arrived onsite to install dye drier and process stub to chest freezer from prior tech’s diagnosis. Removed drier. Installed new UV drier and process stub using braising methods. Vacuumed unit down to -25psi. Charged system with 4.8oz of R134a refrigerant. Powered up unit. Found inner liner started to freeze. Pressures are 2psi low side,120psi high side and holding. Did find signs of corrosion on OEM drier welds. No other issues found."

Near W Moonlight Dr, Robinson, TX 76706
Steve C.

Steve C.

FREEZER WHIRLPOOL WZC3115DW0 Arrived on site for the unit is not freezing. Tested the unit and found the compressor is on and not freezing. The amp draw is 0.6 amps. Called Whirlpool SR # 7723332092 Kurt and advise to replace a uv drier and port and check for leaks. If no leak is found after repair to call Whirlpool again to advise no leak is present and it’s inside the cabinet for non repairable. Office will need to reschedule customer. Need two hours to complete the repair.; ordrng 1 CNOTE (2 HOURS ) and 1 TJ90SF8404 (ACCESS PORT ) and 1 WPW10143759 (dryer UV)

Near W Moonlight Dr, Robinson, TX 76706
Steve C.

Steve C.

WASHER WHIRLPOOL WFW85HEFC1 Arrived on site for the unit is leaking water. Found the bellow torn in the front bottom section. Replaced the bellow and tested the unit. Unit works properly and all water connections were dry at the time of service.

Near Andalusian Ln, Robinson, TX 76706
Steve C.

Steve C.

DRYER WHIRLPOOL WED5000DW2 Arrived on site for the unit is not catching lint. Tested the unit and found the air vent flap is partially open and no air venting. Advice customer to call a vent cleaning crew and to clean air vents every six months.

Near Massey Ln, Robinson, TX 76706
Steve C.

Steve C.

OVEN WHIRLPOOL WOD93EC0AS01 Arrived on site for the unit door will not close. Tested the unit and found the lower over door left side falls off. Disassembled the lower oven door and reset the hinges. Tested the unit and unit works properly. Quoted customer for the labor wo250 $169.99 plus tax. Customer paid in full.

Near Headrick Dr, Robinson, TX 76706
Arthur B.

Arthur B.

WRF989SDAM00 (French Door Dual Evaporator Refrigerator) - Arrived onsite for customer complaint of french door refrigerator not cooling properly. Found RC evaporator is older style silver evaporator. Unit falls under S71233 rework. Removed compressor and evaporator using braising methods. Vacuumed system down to -25psi. Charged with 5.5oz of R134a refrigerant. Tested unit. Found good frost pattern and good air flow from newly installed evaporator. No other issues found. All water connections were dry at time of service.

Near Retoma Park, Robinson, TX 76706
Arthur B.

Arthur B.

GLD4200L00BB (Dishwasher) - Arrived onsite to install new drain pump and cap to dishwasher. Uninstalled dishwasher and removed drain pump assembly. Installed new replacement. Installed rinse aid cap. Reassembled. Tested unit. Unit now fills,washes drain and heats as intended. All water connections were dry at time of service.

Near Rio Bonito Dr, Robinson, TX 76706
Arthur B.

Arthur B.

WTW8000BW0 (Top Load Washer) - Arrived onsite for customer complaint of top load washer getting “LF” error code. Entered diagnostics and confirmed error code. Checked pressure hose and found resistance. Was able to clear pressure hose. Also found drain hose sagging in drain tube. Adjust drain tube. Filled unit and drain. Unit fills and drain and intended. Charged TL120 $129.99 plus taxes. All water connections were dry at time of service.

Near W Shamrock Dr, Robinson, TX 76706
Arthur B.

Arthur B.

RF368LXPB1 (Freestanding Range) - Arrived onsite for customer complaint of freestanding range COOKTOP ON light stays illuminated. Removed back panel and found RF infinite switch faulty. P&L are as follows; WP3140400 (Infinite Switch) $40.85, CO380 $159.99 plus taxes. Removed and replaced RF infinite switch and reassembled. Indicator light now off and works as intended. No other issues found.

Near Turfway Park Dr, Robinson, TX 76706
Arthur B.

Arthur B.

ED5NHAXNB01 (SxS Refrigerator) - Arrived onsite for customer complaint of SxS refrigerator icemaker not producing ice. Found icemaker stripper continuously rotating. P&L are as follows; 2198597 (Icemaker) $130.94, RF360 $169.99 plus taxes. Removed and replaced icemaker. Reassembled. Icemaker called for water immediately. No other issues found. All water connections were dry at time of service.

Near Turfway Park Dr, Robinson, TX 76706
Arthur B.

Arthur B.

WRX988SIBB01 (French Door Refrigerator) - Arrived onsite to install new LH/RH brackets and gasket to FC door from prior tech’s diagnosis. Removed brackets and gaskets and installed new replacements. Used heat gun to shape gasket to cabinet. Door now seats well to cabinet. No other issues found. All water connections were dry at time of service.

Near Ivan Rd, Robinson, TX 76706
Mike G.

Mike G.

WED4815EW1, Arrived on site for unit will run but no heat and timer not working checked unit and fou d that the unit is not getting proper voltage from L1 to L2 no voltage from L1 to N getting 120v and from L2 to N getting 115v found that the it is an electrical issue customer will need an electrician to fix issue

Near Clydesdale Way, Robinson, TX 76706
Mike G.

Mike G.

WED4815EW1, Arrived on site for unit will run but no heat and timer not working checked unit and fou d that the unit is not getting proper voltage from L1 to L2 no voltage from L1 to N getting 120v and from L2 to N getting 115v found that the it is an electrical issue customer will need an electrician to fix issue

Near Clydesdale Way, Robinson, TX 76706
Arthur B.

Arthur B.

MVWX700XW2 (Top Load Washer) - Arrived onsite for customer complaint of top load washer making grinding noises when spinning. Hand spun basket and found bearing in gearcase warn out. Removed gearcase and installed new replacement with cam kit. Reassembled. Calibrated unit. Unit completed successfully. No other issues found. All water connections were dry at time of service.

Near Hawkins, Robinson, TX 76706
Mike G.

Mike G.

Arrived on site for CLOTHING STUCK UNDER AGITATOR, checked unit and found that the agitator is warped removed clothing and replaced agitator and checked unit and unit checked fine at this time... , MVWB765FW0

Near Valley View Dr, Robinson, TX 76706
Mike G.

Mike G.

Arrived on site for CLOTHING STUCK UNDER AGITATOR, checked unit and found that the agitator is warped removed clothing and replaced agitator and checked unit and unit checked fine at this time... , MVWB765FW0

Near Valley View Dr, Robinson, TX 76706
Mike G.

Mike G.

WRF736SDAM11, Arrived on site to install new evap fan motor and blade and r&l pan stops checked unit after repair and unit is starting to cool and is not making noise at time of srv... checked unit for water leaks and no leaks found at time of srv... unit checked fine at this time....

Near Kim Ln, Robinson, TX 76706
Mike G.

Mike G.

WRF736SDAM11, Arrived on site to install new evap fan motor and blade and r&l pan stops checked unit after repair and unit is starting to cool and is not making noise at time of srv... checked unit for water leaks and no leaks found at time of srv... unit checked fine at this time....

Near Kim Ln, Robinson, TX 76706
Mike G.

Mike G.

WRS325FDAB06, Arrived on site to install new harns-wire and defrost control checked unit after repair and as soon as unit was plugged in unit when into defrsot unit is now defrosting on its own checked unit for water leaks and no leaks found at time of srv.... unit checked fine at this time....

Near Jancy St, Robinson, TX 76706
Mike G.

Mike G.

WRS325FDAB06, Arrived on site to install new harns-wire and defrost control checked unit after repair and as soon as unit was plugged in unit when into defrsot unit is now defrosting on its own checked unit for water leaks and no leaks found at time of srv.... unit checked fine at this time....

Near Jancy St, Robinson, TX 76706
Mike G.

Mike G.

WRS325FDAM04, Arrived on site for 3 LOUD THUMPING NOISES/HAPPENS RIGHT AROUND ICE DROP/STARTLING LOUD/2-3 TIMES DAY-EVERYTHING WORKS, checked unit and found that icemaker is broken replaced icemaker and checked unit after repair and unit checked fine at this time... Checked unit for water leaks and no leaks found at time of srv...

Near Turfway Park Dr, Robinson, TX 76706
Mike G.

Mike G.

WRS325FDAM04, Arrived on site for 3 LOUD THUMPING NOISES/HAPPENS RIGHT AROUND ICE DROP/STARTLING LOUD/2-3 TIMES DAY-EVERYTHING WORKS, checked unit and found that icemaker is broken replaced icemaker and checked unit after repair and unit checked fine at this time... Checked unit for water leaks and no leaks found at time of srv...

Near Turfway Park Dr, Robinson, TX 76706
Mike G.

Mike G.

MEDX655DW1, Arrived on site for unit taking to long to dry, chedked unit air flow and unit has no air flow removed vent hose from unit and rechecked air flow with out vent hose and unit now has air flow found that the vent from the wall going out will need to be cleaned out customer will need to have vent from the wall going out side cleaned checked and cleaned all lent found from unit, unit checked fine at this time.....

Near Rio Bonito Dr, Robinson, TX 76706
Mike G.

Mike G.

MEDX655DW1, Arrived on site for unit taking to long to dry, chedked unit air flow and unit has no air flow removed vent hose from unit and rechecked air flow with out vent hose and unit now has air flow found that the vent from the wall going out will need to be cleaned out customer will need to have vent from the wall going out side cleaned checked and cleaned all lent found from unit, unit checked fine at this time.....

Near Rio Bonito Dr, Robinson, TX 76706
Mike G.

Mike G.

MFI2569VEB2, Arrived on site to install main control and UI control replaced main control and pluged in unit to test and reprogram unit and found that the unit started up and compressor came on and started cooling UI control is not need checked unit for water leaks and no leaks leaks found at time of srv... Unit checked fine at this time...

Near Andalusian Ln, Robinson, TX 76706
Mike G.

Mike G.

MFI2569VEB2, Arrived on site to install main control and UI control replaced main control and pluged in unit to test and reprogram unit and found that the unit started up and compressor came on and started cooling UI control is not need checked unit for water leaks and no leaks leaks found at time of srv... Unit checked fine at this time...

Near Andalusian Ln, Robinson, TX 76706
Mike G.

Mike G.

MFI2569VEB2, Arrived on site to install main control and UI control replaced main control and pluged in unit to test and reprogram unit and found that the unit started up and compressor came on and started cooling UI control is not need checked unit for water leaks and no leaks leaks found at time of srv... Unit checked fine at this time...

Near Andalusian Ln, Robinson, TX 76706
Mike G.

Mike G.

MFI2569VEB2, Arrived on site to install main control and UI control replaced main control and pluged in unit to test and reprogram unit and found that the unit started up and compressor came on and started cooling UI control is not need checked unit for water leaks and no leaks leaks found at time of srv... Unit checked fine at this time...

Near Andalusian Ln, Robinson, TX 76706
Mike G.

Mike G.

MDB4949SDM3, Arrived on site for unit not powering on checked unit and found that the power cord was loos uninstalled power cord and rewird power cord pluged unit in and unit is now powering on ran test on unit and all test checked good checked unit for water leaks and no leaks found at rimeof srv.... Unit checked fine at this time.....

Near E Tate Ave, Robinson, TX 76706
Mike G.

Mike G.

MDB4949SDM3, Arrived on site for unit not powering on checked unit and found that the power cord was loos uninstalled power cord and rewird power cord pluged unit in and unit is now powering on ran test on unit and all test checked good checked unit for water leaks and no leaks found at rimeof srv.... Unit checked fine at this time.....

Near E Tate Ave, Robinson, TX 76706
Mike G.

Mike G.

WRS325FDAM04, Arrived on site for unit not making ice when arrived customer stating that the is making but making a buzzing sound when disp checked unit and found that the buzzing sound that the customer is hearing is the motor and is normal checked unit for water leaks and no leaks found at time of srv.... Unit checked fine at this time....

Near Dawn Dr, Robinson, TX 76706
Mike G.

Mike G.

WRS325FDAM04, Arrived on site for unit not making ice when arrived customer stating that the is making but making a buzzing sound when disp checked unit and found that the buzzing sound that the customer is hearing is the motor and is normal checked unit for water leaks and no leaks found at time of srv.... Unit checked fine at this time....

Near Dawn Dr, Robinson, TX 76706
Mike G.

Mike G.

MEC7430BS02, Arrived on site for unit TURNED ON THE BURNER IT POPPED THE BREAKER OFF, checked unit by uninstalling unit and removing glass top from cooktop and checked all elenents and all checked good and checked all switches and all checked good turned power back on to unit and did not trip bracker and checked all burners and all burner and working and heating did fined that the unit wiring does not have a junction box and one cabinet drawer is pushed in his hitting on wiring and may be causing unit to ground and trip the bracker talk to customer about having electrician installing junction box for wiring to cooktop u it checked good at this time.....

Near Hunton Ln, Robinson, TX 76706