Near Seguin, Texas 78155
Daniel A.
Job Details:
03/29/2018
WDF560SAFM2 Not cleaning dishes. Verified voltage to motor sump. Defective. Replaced motor sump. Ran wash cycle. Checked water inlet and drain hoses. No leaks detected. Normal operation after service
Near Seguin, Texas 78155
Daniel A.
Job Details:
03/29/2018
WDF560SAFM2 Not cleaning dishes. Verified voltage to motor sump. Defective. Replaced motor sump. Ran wash cycle. Checked water inlet and drain hoses. No leaks detected. Normal operation after service
Near Austin, Texas 78739
Leonardo
Job Details:
03/29/2018
KitchenAid dishwasher model# KDTE704DSS0 Arrived on site to test unit for not starting. Test unit and found unit not starting due to drain motor being stuck. Removed drain motor and found glass in motor. Removed motor test unit and unit test good no leaks present.
Near Austin, Texas 78738
Connor M.
Job Details:
03/29/2018
JJW3830DS jennair oven Arrived on site to test unit for oven turning off and not responding sometimes. Found failure in UI. Replaced and programmed. Unit working properly at time of service.
Near Leander, Texas 78641
Jerry C.
Job Details:
03/29/2018
WMH32519CS1 Arrived to inspect vent panel. I found one of the mounting tabs along the lower edge was not seated. I removed mounting hardware and correctly seated the tab; issue corrected. Operational test good.
Near Austin, Texas 78739
Leonardo
Job Details:
03/29/2018
Dishwasher KitchenAid not washing. Model# KDTE104DSS0 Arrived on site to test unit for not washing dishes. Test test not and found bad wash motor. Replaced wash motor test unit and unit test good job complete
Near Meadowlakes, Texas 78654
Thomas L.
Job Details:
03/29/2018
DU920PFGQ2 Arrived on site for dishwasher door not closing and unit not operating correctly. Upon further inspection, found that the door was closing properly. Also found that multiple buttons did not work on the Control panel. Office to order control panel and schedule return service. Control panel is discontinued. No leaks observed during service.
Near Meadowlakes, Texas 78654
Thomas L.
Job Details:
03/29/2018
Arrived on site for microwave light blinking. Upon inspection, I could not duplicate the issue. Removed and replaced the upper interlock and switches. Tested unit and it tested good. Job completed.
Near New Braunfels, Texas 78130
Diego G.
Job Details:
03/29/2018
Arrived on site. Check for no operation issues. Found loose connection at main control board now allowing control panel to kick on. Re-position connector to main board. All functions tested OK. No leaks present. Job complete
Near New Braunfels, Texas 78130
Diego G.
Job Details:
03/29/2018
Arrived on site. Check for no operation issues. Found loose connection at main control board now allowing control panel to kick on. Re-position connector to main board. All functions tested OK. No leaks present. Job complete
Near New Braunfels, Texas 78130
Diego G.
Job Details:
03/29/2018
Arrived on site. Check for no operation issues. Found loose connection at main control board now allowing control panel to kick on. Re-position connector to main board. All functions tested OK. No leaks present. Job complete
Near Temple, Texas 76502
Dona
Job Details:
03/29/2018
Arrived on site to inspect unit. Temperatures checked good. Seals looked good, no abnormal noises. Instructed customer to get ducting cleaned. All ops checked good. Water connections dry. Sarah collected payment at office as I pad would not collect.
Near Temple, Texas 76502
Dona
Job Details:
03/29/2018
Arrived on site for f51 error code. Found bearing starting to wear and not allowing disengagement from basket. Found right rear suspension rod sprung causing noise and off balance conditions. Unit would need bearing and suspensions. Customer does not want to repair at this time. Sarah collected payment from office as payment would not process on I pad. All water connections dry.
Near Meadowlakes, Texas 78654
Thomas L.
Job Details:
03/29/2018
RBS305PDQ6 arrived on site to inspect oven door glass broken and unit tripping circuits in clean mode. Upon further inspection, found that the door glass was broken and when placed in clean mode, the unit showed F5E1 error code, door latch not locking. Office to order inner glass, door latch, and control and schedule return service. Control is discontinued.
Near Round Rock, Texas 78664
Nathaniel B.
Job Details:
03/29/2018
Model WRT318FZDW02, Arrived on call for improper temps in fresh food and freezer, installed previously diag. Parts, updated control and both sensers and instructed customer to allow for 24-48 hours for proper cooling, no water leaks at time of call, call complete.
Near Round Rock, Texas 78664
Nathaniel B.
Job Details:
03/29/2018
Model WRT318FZDW02, Arrived on call for improper temps in fresh food and freezer, installed previously diag. Parts, updated control and both sensers and instructed customer to allow for 24-48 hours for proper cooling, no water leaks at time of call, call complete.
Near New Braunfels, Texas 78132
Daniel A.
Job Details:
03/28/2018
MEDX655DW1 Dryer not coming on. Push to start switch out of position. Accessed control panel Replaced push to start switch. Verified normal position. Instruct customer on venting/fire hazard
Near New Braunfels, Texas 78132
Daniel A.
Job Details:
03/28/2018
WRX986SIHZ00 When dispensing water does not indicate how many ounces are being dispensed. Contacted tech assist. Verified normal water dispensing operation. Per tech assist will only show ounces when measured fill used. No leaks detected
Near Elgin, Texas 78621
Joseph C.
Job Details:
03/28/2018
KDTE704DWH0 Arrived on site for “console has no functionality” complaint. Inspected unit and found console shorted, due to water intrusion. Ordering new. Parts are $262.87. Labor is $184.99 (DW135/MT350). Service fee paid. Return for repairs on 04/04. No leaks detected, at time of service.
Near Temple, Texas 76501
Dona
Job Details:
03/28/2018
Arrived on site for frost throughout freezer. Installed door that had seal from factory. Leveled door, door is sealing shut does not appear warped and is not allowing air inside unit from ambient temperatures. No water connections.
Near Georgetown, Texas 78633
Mike C.
Job Details:
03/28/2018
Whirlpool microwave WMH32519FT0 Arrived to install new control and humidity sensor. Checked operation and unit checks good.
Near Temple, Texas 76502
Dona
Job Details:
03/28/2018
Arrived on site for warm zone button had fallen into control. Removed rear panel found warm zone push button was not lined up in correct position. Reseated put in locked position. Checked all burners all checked good.
Near Austin, Texas 78737
Luis
Job Details:
03/28/2018
Refrigerator-removed obstruction in icemaker
Near Harker Heights, Texas 76548
Mike G.
Job Details:
03/28/2018
MEDX700XL0, Arrived on site for unit making a noise, checked unit and found that the rollers have gone bad used dryer repair kit to replaced pully and rollers and checked and cleaned out all lent found from unit and test unit and unit is no longer making noise and is heating and has good air flow unit checked fine at this time.....
Near Harker Heights, Texas 76548
Mike G.
Job Details:
03/28/2018
MEDX700XL0, Arrived on site for unit making a noise, checked unit and found that the rollers have gone bad used dryer repair kit to replaced pully and rollers and checked and cleaned out all lent found from unit and test unit and unit is no longer making noise and is heating and has good air flow unit checked fine at this time.....
Near Burnet, Texas 78611
Thomas L.
Job Details:
03/28/2018
Arrived on site for no fan operation. Found fan was electrically shorted. Replaced and tested.
Near Buda, Texas 78610
Brandon
Job Details:
03/28/2018
Arrived on site for washer not working properly and loud noise, found bad bearings, replaced bearings, unit tested good, no water leaks at time of service.
Near Buda, Texas 78610
Brandon
Job Details:
03/28/2018
Arrived on site for dryer not turning on, found motor was not running, opened door and held down door switch and manually turned drum by hand, the motor would then turn the drum. I gained access to blower wheel, blower wheel was clear of an debris, found bad start windings on motor. I collected service fee $108.24 customer is going with repair. Vent was clear at time of service.
Near Temple, Texas 76502
Dona
Job Details:
03/28/2018
Arrived on site for door not shutting smoothly, tracks are not lining up. Customer has spoken to tri supply the company that sold the unit. Customer does not want unit fixed she is getting a replacement.
Near Austin, Texas 78728
Scott
Job Details:
03/28/2018
Near Austin, Texas 78728
Scott
Job Details:
03/28/2018
Near Austin, Texas 78728
Scott
Job Details:
03/28/2018
Arrived on site replaced control and UI console . Ran diagnostics unit functioned normally . Remaining labor 100.00 ,parts are covered . Collected 108.25 w/tax . No water leaks detected at time of service . Job complete
Near Austin, Texas 78728
Scott
Job Details:
03/28/2018
Arrived on site for no heat dryer . Found heating element had burned out . Did check fuse and thermostat stats , all checked good . Cleaned lint out of unit . Replaced element . Unit is now heating properly . No lint build up at time of service . Job complete .
Near Harker Heights, Texas 76548
Mike G.
Job Details:
03/28/2018
WMH73521CS6, Arrived on site for hood light will not turn on checked unit and found that the lamp holder is shorted out replaced part and tested unit and hood light still not turning on found that the control is bad and will need to be replaced ordering part per SW r/s next apt for 4/3/18
Near Harker Heights, Texas 76548
Mike G.
Job Details:
03/28/2018
WMH73521CS6, Arrived on site for hood light will not turn on checked unit and found that the lamp holder is shorted out replaced part and tested unit and hood light still not turning on found that the control is bad and will need to be replaced ordering part per SW r/s next apt for 4/3/18
Near Cedar Park, Texas 78613
Jerry C.
Job Details:
03/28/2018
WOD51EC0AS01 arrived on site for oven not operating and bottom door locked up. Upon further inspection, customer advised they placed the unit in self clean and the unit stopped working locking the bottom door. Verified ohms at the fuse and found it to be open. Removed/replaced the fuse and tested the unit. Unit operated as designed; job completed.
Near Austin, Texas 78748
Luis
Job Details:
03/28/2018
Icemachine-replaced faulty water sensor
Near Austin, Texas 78748
Luis
Job Details:
03/28/2018
Refrigerator-removed ice blockage replaced ice bin
Near Austin, Texas 78748
Luis
Job Details:
03/28/2018
Refrigerator-removed ice blockage replaced ice bin
Near Kingsland, Texas 78639
Thomas L.
Job Details:
03/28/2018
Arrived on site for no ice condition. Found freezer temperature at 1°. Found icemaker has power to it. Found icemaker stall in the park position. It did have frozen ice in the mold. Replaced ice maker and new icemaker cycle properly with no water leaks.
Near Kingsland, Texas 78639
Thomas L.
Job Details:
03/28/2018
Arrived on site for no ice condition. Found freezer temperature at 1°. Found icemaker has power to it. Found icemaker stall in the park position. It did have frozen ice in the mold. Replaced ice maker and new icemaker cycle properly with no water leaks.
Near Austin, Texas 78723
Joseph C.
Job Details:
03/28/2018
IBS550PWS01 Arrived on site for “F1 error code” complaint. Per my previous diagnosis, removed and replaced control. Tested unit. Unit is performing as designed.
Near Austin, Texas 78731
Robert
Job Details:
03/28/2018
Wfw85hefw washer Whirlpool Control.
Near Belton, Texas 76513
Dona
Job Details:
03/28/2018
L1 to neutral 113volts ac. L2 to neutral 130 volts ac. Without load. Push to start engaged drops voltage to 58 volts on l1 to neutral. L2 to neutral jumps to 186 volts. Unit will run after initial depression and hold of push to start. Voltage returns to 113 volts and 130 volts. Instructed customer on improper line voltage too much variance between l1 to l2. Motor checks ok and push to start checks ok. Customer needs an electrician. Collected 108.24 on a card. Jordan helped with payment as would not process. On iPad went through. Instructed customer if double charged to call office.
Near Marble Falls, Texas 78654
Thomas L.
Job Details:
03/28/2018
Arrived on site for no light operations. And the bottom right bulb in the bottom left bulb or defective. Top left Bulb was loose and socket.
Near Marble Falls, Texas 78654
Thomas L.
Job Details:
03/28/2018
Arrived on site for no light operations. And the bottom right bulb in the bottom left bulb or defective. Top left Bulb was loose and socket.
Near Marble Falls, Texas 78654
Thomas L.
Job Details:
03/28/2018
Arrived on site for no poor condition. Found unit running and both compartments were at 66°. Compressor was running. Evacuated system, vacuumed system, recharged system. Unit held vacuum and started to Frosty evaporator. Customer to allow 24 hours to reach proper operating.
Near Leander, Texas 78641
Cliff
Job Details:
03/28/2018
Kitchenaid refrigerator KRMF706ESS01. Arrived on site to replace compressor, filter dryer, right side roller, and ice bin door. Replaced all parts and Paul deep vacuum on unit. Charged unit with 6 ounces of Freon per manufacturers recommendations, and I tested unit. Found all is functioning properly at this time. No water leaks were found at time of service.
Near Marble Falls, Texas 78654
Thomas L.
Job Details:
03/28/2018
Arrived on site for no poor condition. Found unit running and both compartments were at 66°. Compressor was running. Evacuated system, vacuumed system, recharged system. Unit held vacuum and started to Frosty evaporator. Customer to allow 24 hours to reach proper operating.
Near Georgetown, Texas 78628
Jonathan S
Job Details:
03/28/2018
Frigidaire dishwasher model #FDB520RHS2A. Leaking water and will not drain.
Near Jarrell, Texas 76537
Dona
Job Details:
03/28/2018
Arrived on site for left front burner continually on high. Found left front infinite switch with burnt contact. Replaced infinite switch. All ops check good. All other burners check good. Temps in oven checked good.
Near Fort Hood, Texas 76544
Mike G.
Job Details:
03/28/2018
MZF34X16DW00, Arrived on site for unit making noise, checked unit and found that the noise is evap fan hitting on ice unit is going into defrost ice is only around evap fan do to door being left open defrosted ice from evap fan checked unit and unit is no longer making noise checked unit for water leaks and no leaks found at time of srv.... unit checked fine at this time.... RF520 $149.99 + tax
Near Fort Hood, Texas 76544
Mike G.
Job Details:
03/28/2018
MZF34X16DW00, Arrived on site for unit making noise, checked unit and found that the noise is evap fan hitting on ice unit is going into defrost ice is only around evap fan do to door being left open defrosted ice from evap fan checked unit and unit is no longer making noise checked unit for water leaks and no leaks found at time of srv.... unit checked fine at this time.... RF520 $149.99 + tax
Near Austin, Texas 78703
Joseph C.
Job Details:
03/28/2018
WGD75HEFW0 Arrived on site for “dryer not heating” complaint. Per my previous diagnosis, removed and replaced ignitor. Tested unit. Unit is performing as designed. No leaks detected, at time of service. Instructed customer to clean venting every six months to prevent possible fire hazards and for better performance and economy.
Near Austin, Texas 78703
Joseph C.
Job Details:
03/28/2018
Near Marble Falls, Texas 78654
Thomas L.
Job Details:
03/28/2018
Arrived on site for no operation and prior poor washability. Found that the unit was in a failure mode due to a shorted dry heater. Tested unit in diagnostics, found failed soap dispenser, weak wash motor, split spray arms, and leaking inner door liner.
Spray arms
Pump
Heater
Door liner
Gasket
Soap dispenser
259
271
Near Jarrell, Texas 76537
Dona
Job Details:
03/28/2018
Arrived on site for noise complaint, ran unit through fill, agitation, drain and spin. Found no abnormal noise. Instructed customer on normal noises of splutch changing station of motion from agitate. Unit is not hooked to hot water at this time. All water connections dry. Unit running to spec.
Near Georgetown, Texas 78633
Jonathan S
Job Details:
03/28/2018
Maytag range model# MGR4452BDS. Cooktop burners flames are to big and unit is putting out smell
Near Austin, Texas 78748
Brandon
Job Details:
03/28/2018
Arrived on site for dryer not turning on, found motor was not running, opened door and held down door switch and manually turned drum by hand, the motor would then turn the drum. I gained access to blower wheel, blower wheel was clear of an debris, found bad start windings on motor. I collected service fee $108.24 customer is going with repair. Vent was clear at time of service.
Near Marble Falls, Texas 78654
Thomas L.
Job Details:
03/28/2018
Arrived on site for no convection bake fan operation. Arrived on site and tested convection bake function. Found that the convection bake fan did not run. Found that the convection bake fan was defective. Replaced and re-tested operation. Operations are now correct.
Near Killeen, Texas 76542
Mike G.
Job Details:
03/28/2018
WMH31017FS0, Arrived on site for unit not starting, checked unit and found that the bottom diir switch is bad replaced top and bottom interlocks and all 3 door switches and checked unit and unit is now starting and heating unit checked fine at this time.....
Near Killeen, Texas 76542
Mike G.
Job Details:
03/28/2018
WMH31017FS0, Arrived on site for unit not starting, checked unit and found that the bottom diir switch is bad replaced top and bottom interlocks and all 3 door switches and checked unit and unit is now starting and heating unit checked fine at this time.....
Near Georgetown, Texas 78633
Steve C.
Job Details:
03/28/2018
Arrived on site to replace the glass due to stain between the glass. Replaced the part and tested the unit. Unit works properly and all water connections were dry at the time of service.
Near Georgetown, Texas 78633
Steve C.
Job Details:
03/28/2018
Arrived on site for the unit has error code f9e1 long drain. Tested the unit and found the unit will not drain. Removed the water and removed the drain catch and found clothing items. Removed the items and tested the unit. Unit works properly and all water connections were dry at the time of service.
Near Manor, Texas 78653
Joseph C.
Job Details:
03/27/2018
WRT318FZDM01 Arrived on site for “freezing in fresh foods and not in the freezer” complaint. Per my previous diagnosis, removed and replaced control and all thermistors. Unit checks good. No water connected to unit.
Near Manor, Texas 78653
Joseph C.
Job Details:
03/27/2018
WFG505M0BS3 Arrived on site for “stainless door trim is coming off” complaint. Per my previous diagnosis! Removed and replaced front section of oven door. Unit is performing as designed. No leaks detected, at time of service.
Near Georgetown, Texas 78628
Mike C.
Job Details:
03/27/2018
Kitchen Aid dishwasher KDTM354DSS4 Arrived to check unit for poor wash performance. Put unit into diagnostics and ran a automatic diagnostics cycle and found wash motor not pumping water. Found wash motor bad. Installed new wash motor and checked operation, checked good with no water leaks.
Near Round Rock, Texas 78665
Jonathan S
Job Details:
03/27/2018
Whirlpool dishwasher model# WDT750SAHZ0. Unit will not work unless pressing up against door.
Near Killeen, Texas 76543
Dona
Job Details:
03/27/2018
Arrived on site for ice build up. Found unit with good frost pattern no excessive build up. Ran unit through all tests. Bi-metal checked correctly, defrost heater checked good. Checked drip pan delivery tube all clear nothing building up not allowing for flow from freezer during defrost. Temperatures in fridge are 37 degrees where customer has set. Freezer is at 3 degrees. Airflow good from freezer to fridge. All water connections dry. Unit is working to spec at this time. Defrost is set to run every 8 hours on adc.
Near Georgetown, Texas 78628
Cliff
Job Details:
03/27/2018
Whirlpool dishwasher WDF330PAHS1. Arrived on site to diagnose a dishwasher with a dented panel. Found front panel dented on lower center section. Replaced panel and tested unit. Found all is functioning properly at this time. No leaks were found at time of service.
Near Waco, Texas 76712
Mike G.
Job Details:
03/27/2018
MEDC215EW1, Arrived on site formunit will not start checked unit and found that the door switch is broken replaced door switch and checked and cleaned out all lent found from unit and tested unit and unit is now starting and heating unit checkef fine at this time....,
Near Waco, Texas 76712
Mike G.
Job Details:
03/27/2018
MEDC215EW1, Arrived on site formunit will not start checked unit and found that the door switch is broken replaced door switch and checked and cleaned out all lent found from unit and tested unit and unit is now starting and heating unit checkef fine at this time....,
Near Austin, Texas 78739
Daniel A.
Job Details:
03/27/2018
KFCS22EVMS8 Not producing ice. Defective icemaker not advancing to harvest mode. Getting voltage. Replaced icemaker. Verified normal fill after service. Noisy damper control when energized. Replaced damper control. Defective gear motor. Normal operation after service. No air leaks detected
Near San Marcos, Texas 78666
Diego G.
Job Details:
03/27/2018
Arrived on site. Replaced all controls on unit. Ran diagnostics testAnd checked all components., all functions tested OK. No leaks present. Job complete
Near San Marcos, Texas 78666
Diego G.
Job Details:
03/27/2018
Arrived on site. Replaced all controls on unit. Ran diagnostics testAnd checked all components., all functions tested OK. No leaks present. Job complete
Near San Marcos, Texas 78666
Diego G.
Job Details:
03/27/2018
Arrived on site. Replaced all controls on unit. Ran diagnostics testAnd checked all components., all functions tested OK. No leaks present. Job complete
Near Austin, Texas 78717
Jonathan S
Job Details:
03/27/2018
Whirlpool refrigerator model # Not dispensing ice from dispenser. Arrived on site for refrigerator d
Near Austin, Texas 78717
Jonathan S
Job Details:
03/27/2018
Whirlpool refrigerator model# GS5SHGXLS00
Near Killeen, Texas 76543
Dona
Job Details:
03/27/2018
Arrived on site to check for resale. Ran unit dry as there are no water hookups. Unit had no save errors. Spun and drained correctly. Checked all water connections were tight and in place. Suspension on unit checks good did not go off balance. Spin speed in high no abnormal noises. all dry checks checked good.
Near Austin, Texas 78731
Scott
Job Details:
03/27/2018
Arrived on site for DW not responding . Did check outlet and power cord connections to unit , both checked good . Found key pad not responding . Checked connections , did find a burn mark on UI board . Checked control , appeared to be fine . Replaced UI , unit did respond to commands . Ran diagnostics cycle , got stuck keypad error code . Unit ran diagnostics , every thing checked out normal . No water leaks detected at time of service . Job complete .
Near Austin, Texas 78723
Joseph C.
Job Details:
03/27/2018
KDTE204GPS0 Arrived on site for “damaged dishwasher console” complaint. Inspected unit and found corner chipped, on console. Removed and replaced control panel. Tested unit. Unit is performing as designed. No leaks detected, at time of service.
Near Waco, Texas 76710
Mike G.
Job Details:
03/27/2018
WTW4816FW2, Arrived on site for unit not spining out and getting off Balance, checked unit and found no error codes and recalibrated unit and ran test and unit ran all test fine talked to customer about how to load unit and how much HE soap to use checked unit for water leaks and no leaks found at time of srv..l. Unit checked fine at this time....
Near Waco, Texas 76710
Mike G.
Job Details:
03/27/2018
WTW4816FW2, Arrived on site for unit not spining out and getting off Balance, checked unit and found no error codes and recalibrated unit and ran test and unit ran all test fine talked to customer about how to load unit and how much HE soap to use checked unit for water leaks and no leaks found at time of srv..l. Unit checked fine at this time....
Near Killeen, Texas 76543
Dona
Job Details:
03/27/2018
Arrived on site to check for resale. Ran unit dry as there are no water hookups. Unit had no save errors. Spun and drained correctly. Checked all water connections were tight and in place. Calibrated unit all dry checks checked good.
Near New Braunfels, Texas 78130
Diego G.
Job Details:
03/27/2018
Arrived on site. Check for handle issues. Found handles not secured by installers correctly. Adjusted handle and re-secured. Also verified icemaker cycling correctly. All functions tested OK. No leaks present. Job complete
Near New Braunfels, Texas 78130
Diego G.
Job Details:
03/27/2018
Arrived on site. Check for handle issues. Found handles not secured by installers correctly. Adjusted handle and re-secured. Also verified icemaker cycling correctly. All functions tested OK. No leaks present. Job complete
Near New Braunfels, Texas 78130
Diego G.
Job Details:
03/27/2018
Arrived on site. Check for handle issues. Found handles not secured by installers correctly. Adjusted handle and re-secured. Also verified icemaker cycling correctly. All functions tested OK. No leaks present. Job complete
Near Cedar Park, Texas 78613
Jonathan S
Job Details:
03/27/2018
Maytag dryer model #MED6000AG0. Not able to remove lint catcher.
Near Austin, Texas 78744
Daniel A.
Job Details:
03/27/2018
RTW4516FW2 Lid lock not locking/unlocking. Unable to enter diagnostic. Lid lock led flashing. Replaced control. Ran automtest. Normal operation after service Checked water inlet and drain hoses. No leaks detected
Near Austin, Texas 78724
Joseph C.
Job Details:
03/27/2018
WRV986FDEM01 Arrived on site for “ice forming under drawers and French door not sealing” complaint. Per my previous diagnosis, removed and replaced mullion. Cleared drain line for fresh foods defrost tray. Unit is performing as designed. No leaks detected, at time of service.
Near Austin, Texas 78724
Joseph C.
Job Details:
03/27/2018
Near Killeen, Texas 76543
Dona
Job Details:
03/27/2018
Arrived on site for unit not drying clothes. Found dryer venting completely clogged off not allowing for air flow. Unit heats & tumbles removed clogged duct work. Showed customer airflow restrictions . Temperatures checked good after removing clog. Dryer vent clear.
Near Killeen, Texas 76543
Dona
Job Details:
03/27/2018
Arrived on site for washer not advancing on cycle. Customer uses warm water on all loads. Found hot water hose on house side, kinked not allowing for water flow to satisfy pressure switch to move to next part of cycle. Unkinked hose, ran cycle through . Unit filled, agitated, drained and spun. No abnormal noises all water connections dry. Units water hoses are not stationary in wall they are exposed.
Near New Braunfels, Texas 78130
Diego G.
Job Details:
03/27/2018
Arrived on site. Check for draining issues. Found unit not draining water. Remove bottom panel and found loose connection at drain pump. Re-position and reconnected drain pump connector. Ran diagnostic test, all functions tested OK. No leaks present. Job complete
Near New Braunfels, Texas 78130
Diego G.
Job Details:
03/27/2018
Arrived on site. Check for draining issues. Found unit not draining water. Remove bottom panel and found loose connection at drain pump. Re-position and reconnected drain pump connector. Ran diagnostic test, all functions tested OK. No leaks present. Job complete
Near New Braunfels, Texas 78130
Diego G.
Job Details:
03/27/2018
Arrived on site. Check for draining issues. Found unit not draining water. Remove bottom panel and found loose connection at drain pump. Re-position and reconnected drain pump connector. Ran diagnostic test, all functions tested OK. No leaks present. Job complete
Near Austin, Texas 78731
Scott
Job Details:
03/27/2018
Kitchenaid dish washer , dented door
Near Austin, Texas 78731
Scott
Job Details:
03/27/2018
Arrived on site for steam valve dripping . Found valve leaking . Ordering valve W11179718. Return 4/3 . For now water is disconnected from dryer . Unit is free from lint at time of service . Quick pic of pop.
Near Cedar Park, Texas 78613
Wesley
Job Details:
03/27/2018
Arrived on site and found unit motor shorted. Replaced motor and tested. All checks good. No leaks at time of service. Unit operating as designed.
Near Copperas Cove, Texas 76522
Steve C.
Job Details:
03/27/2018
Arrived on site for the unit has error code f9e1 long drain. Tested the unit and found the unit will not drain. Removed the water and removed the drain catch and found clothing items. Removed the items and tested the unit. Unit works properly and all water connections were dry at the time of service.