Near Round Rock, Texas 78665
Tyler B.
Job Details: 10/04/2018
Near Austin, Texas 78724
Joseph C.
Job Details: 10/04/2018
WED7500GC0 Arrived on site for “broken door handle” complaint. Inspected unit and found door striker to be broken from unit, due to weakened door catch. Ordering new catch and striker. Return for repairs on Tuesday 10/09. Instructed customer to clean venting every six months to prevent possible fire hazards and for better performance and economy.
Near Austin, Texas 78724
Robert
Job Details: 10/04/2018
WED4616FW0 Arrived on job to replace timer. After replacement test dryer allowing time to run until self termination of cycle.
Near Round Rock, Texas 78664
Tyler B.
Job Details: 10/04/2018
Near Austin, Texas 78721
Joseph C.
Job Details: 10/04/2018
WFG505M0BS3 Arrived on site for “oven temps too high” complaint. Inspected unit and took temp readings, using “Whirlpool Approved” three count method. Temps were 25 degrees(average) over desired setpoint temp. Calibrated unit. Retested. Unit is performing to within standard tolerances. No leaks detected, at time of service.
Near Austin, Texas 78721
Joseph C.
Job Details: 10/04/2018
WFG505M0BS3 Arrived on site for “oven temps too high” complaint. Inspected unit and took temp readings, using “Whirlpool Approved” three count method. Temps were 25 degrees(average) over desired setpoint temp. Calibrated unit. Retested. Unit is performing to within standard tolerances. No leaks detected, at time of service.
Near Robinson, Texas 76706
Arthur B.
Job Details: 10/04/2018
WRF989SDAM00 (French Door Dual Evaporator Refrigerator) - Arrived onsite for customer complaint of french door refrigerator not cooling properly. Found RC evaporator is older style silver evaporator. Unit falls under S71233 rework. Removed compressor and evaporator using braising methods. Vacuumed system down to -25psi. Charged with 5.5oz of R134a refrigerant. Tested unit. Found good frost pattern and good air flow from newly installed evaporator. No other issues found. All water connections were dry at time of service.
Near Hutto, Texas 78634
Wesley
Job Details: 10/04/2018
Arrive on site and found fridge gasket pulled out of position on top. Rest position. Advised customer on findings. All checks good. Unit is now operating as designed.
Near Round Rock, Texas 78664
Tyler B.
Job Details: 10/04/2018
Near Cedar Park, Texas 78613
James
Job Details: 10/04/2018
Arrived on site and tested operation. Found no heat from dryer and all other functions test good. Found thermostat has failed on dryer. Quoted customer $60.58 plus tax for thermostat kit and $159.99 plus tax labor(DR580). Installed new thermostat kit and vacuumed lint from machine. Tested for proper operation and found unit working properly. Job complete
Near Manor, Texas 78653
Thomas L.
Job Details: 10/04/2018
Arrived on site to find fresh food section at 35 degrees and freezer section at 19 degrees. Found totally restricted condenser restricting air flow. Cleaned condenser. Found restriction in capillary restricting refrigerant flow. Replaced filter dryer. Vaccine used system and recharged. Flow of refrigerant is now proper. No water is connected to this unit. Fresh food 35 Freezer 19
Near Del Valle, Texas 78617
Robert
Job Details: 10/04/2018
WFC150M0EB2 Arrived on job for complaints of burners not working correctly. Test all burners and operation normal.
Near Georgetown, Texas 78633
Lou
Job Details: 10/03/2018
arrived on site to install cooktop glass. Upon arrival, I met with the customer and inspected the glass cooktop to find that it was cracked near the vent. I quoted the customer CO230 $219.99 for a total including tax of $238.14 for service/labor fees. The cooktop ad accessories were covered by whirlpool. The customer agreed to the repair and paid in full. I removed and replaced the glass cooktop and trim ad tested the unit. Unit operated as designed. Using my silver tape, I sealed the vent hose underneath the cooktop. Job completed.
Near Elgin, Texas 78621
Wesley
Job Details: 10/03/2018
Arrived on site and found unit fuse blown. Replaced fuse. Now dryer heats as designed. Customer cleaned lint out of vent.
Near Dripping Springs, Texas 78620
Robert
Job Details: 10/03/2018
MVWB725BW0 Arrived on job to replace hub. After replacement of hub test operation, all good. No leaks detected.
Near Marble Falls, Texas 78654
Thomas L.
Job Details: 10/03/2018
SR#7723109780
Near Harker Heights, Texas 76548
Arthur B.
Job Details: 10/03/2018
WRF555SDFZ05 (French Door Refrigerator) - Arrived onsite for customer complaint of FC door on French door refrigerator binding when opening. Found LH rail is hard to open. Removed and replaced rails. Reassembled. Door now open and closes well. No other issues found. All water connections were dry at time of service.
Near Killeen, Texas 76543
Arthur B.
Job Details: 10/03/2018
GTD65EBPLDG (Dryer) - Arrived onsite for dealer request to check dryer for operations. Tested unit with power supply and found dryer heats and tumbles as intended. No other issues found. Dryer vent clean of lint since dryer is new.
Near Georgetown, Texas 78628
Lou
Job Details: 10/03/2018
arrived on site inspect dryer not working and showing error code. Upon further inspection, the customer attempted to start the unit ad it failed then showed error code F1. I verified the error code through the tech sheet and it reported to replaced the main control. I removed the top of the unit to expose the control ad drum. I quoted the customer $220.03 for the control and DR300 $159.99 for diagnosis/labor fee for a total including tax of $411.37. The customer agreed to the repair and paid in full. I removed and replace the main control ad tested the unit. The unit operated as designed. No lint observed during service, job completed.
Near Manor, Texas 78653
Wesley
Job Details: 10/03/2018
Arrived on site and found unit working properly. Restored water to unit. All checks good. In diagnostics. No leaks.
Near Hutto, Texas 78634
Jonathan S
Job Details: 10/03/2018
Whirlpool refrigerator model# WRF540CWHZ01. Refrigerator doors not aligned.
Near Pflugerville, Texas 78660
Wesley
Job Details: 10/03/2018
Arrived on site and restored broken lights with new lighting board. Now lights work properly. All checks good.
Near Kingsland, Texas 78639
Thomas L.
Job Details: 10/03/2018
Arrived on site or noisy operation during the Fill cycle. Turned off the faucet to the ice machine and it continued to fill and is now quiet. With customers permission we left that faucet in the off position and he is aware of that information. All water connections are dry.
Near Austin, Texas 78737
Robert
Job Details: 10/03/2018
LSQ8243HQ0 Arrived on job for complaints of no spinning or draining. Found lid switch damaged. Replaced switch and test. Operation normal
Near Temple, Texas 76502
Steve C.
Job Details: 10/03/2018
Arrived on site for the unit bake element caught fire. Found the the bake element broke in two on the right rear corner. Replaced the bake element and tested the unit. Unit heats and works properly.
Near Kempner, Texas 76539
Arthur B.
Job Details: 10/03/2018
JK5500DF3BB (Wall Oven) - Arrived onsite for wall oven making loud noises when self clean cycle is used. Tested unit. Found all work as intended. Fan also work as intended. Could not replicate issues. Advised customer if happens again to make a video. No other issues found.
Near Austin, Texas 78735
Luis
Job Details: 10/03/2018
Built in kitchen aid- replaced failed fan motor
Near Horseshoe Bay, Texas 78657
Thomas L.
Job Details: 10/03/2018
Arrived on site for leaking water condition. Found fill line at valve is cracked and leaking. Replaced water line. All water connections are now dry. Customer had to leave before repairs were done. Unit is in an outside kitchen.
Near New Braunfels, Texas 78132
Diego G.
Job Details: 10/03/2018
Arrived on site. Replace control panel, switches, lever and latch. All functions tested OK. Job complete
Near New Braunfels, Texas 78132
Diego G.
Job Details: 10/03/2018
Arrived on site. Replace control panel, switches, lever and latch. All functions tested OK. Job complete
Near New Braunfels, Texas 78132
Diego G.
Job Details: 10/03/2018
Arrived on site. Replace control panel, switches, lever and latch. All functions tested OK. Job complete
Near Driftwood, Texas 78619
Robert
Job Details: 10/03/2018
KDTM354DSS4 Arrived on job for complaints of upper rack falling. Replaced adjuster on left side and test operation. No leaks detected
Near San Marcos, Texas 78666
Derek S.
Job Details: 10/03/2018
MVWB835DW3 Arrived on site to repair unit for long fill. I found the water valve housing faulty due to mechanical failure, replaced the water valve and verified operations, no water leak present at the time of service
Near San Marcos, Texas 78666
Derek S.
Job Details: 10/03/2018
MVWB835DW3 Arrived on site to repair unit for long fill. I found the water valve housing faulty due to mechanical failure, replaced the water valve and verified operations, no water leak present at the time of service
Near Killeen, Texas 76542
Arthur B.
Job Details: 10/03/2018
WRF736SDAM13 (French Door Refrigerator) - Arrived onsite for customer complaint of french door refrigerator not cooling properly. Inspected evaporator and found all frozen over. Also found damper not opening up in RC section. Unit will need new control,UI and damper to complete repair. Customer will have unit defrosted prior tomR/V. OF to R/S after authorization is given for parts. All water connections were dry at time of service.
Near Killeen, Texas 76542
Arthur B.
Job Details: 10/03/2018
WRS325FDAM04 (SxS Refrigerator) - Arrived onsite for customer complaint of SxS refrigerator leaking water from dispenser area and LED lights not working as well. Tested unit and found slow water flow at dispenser. Also found ice maker leaking into bin causing ice to clump up. Will also need LED assembly to complete repair. R/S for 10/8. All water connections were dry at time of service.
Near San Marcos, Texas 78666
Derek S.
Job Details: 10/02/2018
RTW4516FW2 Arrived on site to repair unit for water leak, I found a wire lodged in the propeller drain pump causing leak, cleared out the pump and verified is draining as designed, no water leak present at the time of service
Near San Marcos, Texas 78666
Derek S.
Job Details: 10/02/2018
RTW4516FW2 Arrived on site to repair unit for water leak, I found a wire lodged in the propeller drain pump causing leak, cleared out the pump and verified is draining as designed, no water leak present at the time of service
Near San Marcos, Texas 78666
Derek S.
Job Details: 10/02/2018
WRF535SWHZ00 Arrived on site to repair unit for no ice, i found that the icemaker was connection to unit harness was not seated correctly, I reconnected the icemaker and uni5 started a harvest cycle, verified icemaker filled with water, no water leak present at the time of service
Near San Marcos, Texas 78666
Derek S.
Job Details: 10/02/2018
WRF535SWHZ00 Arrived on site to repair unit for no ice, i found that the icemaker was connection to unit harness was not seated correctly, I reconnected the icemaker and uni5 started a harvest cycle, verified icemaker filled with water, no water leak present at the time of service
Near Austin, Texas 78753
Wesley
Job Details: 10/02/2018
W11245251 Switch kit service pointer. SR 7723100107 Talked with techline after repeat symptom and found wiring to be miswired from factory. Was advised to re wire with switch kit according to service pointer. Ordering switch kit to repair. All else checks good.
Near Georgetown, Texas 78633
Tyler B.
Job Details: 10/02/2018
Near Cedar Park, Texas 78613
Lou
Job Details: 10/02/2018
arrived one ore to inspect dryer not drying. Upon further inspection, using my dryer vent tester kit, I placed the tester inside the drum on the air vent and placed the unit in fluff mode and tested. The card to the kit never fell off on any test (3 times). I turned the heat on to the unit at the console and turned the unit on and felt a little heat. I removed the back panel to expose the wiring , fuse, cutoffs and element. I verified ohms to all of the components. I removed the element to further inspect and found that the e the element assembly was burnt and will crack soon, but the element checked good on ohms. I removed and replaced the element to prevent a future call back. In the process of removing the connections, one of the connectors broke so I had to use the cutoff that was prescreened and I used the wire that was in the cutoff packaging to repair the broken connector. I tested the unit and it operated as designed other then poor airflow. I advised the customer of my finding
Near Georgetown, Texas 78633
Tyler B.
Job Details: 10/02/2018
Near Robinson, Texas 76706
Arthur B.
Job Details: 10/02/2018
GLD4200L00BB (Dishwasher) - Arrived onsite to install new drain pump and cap to dishwasher. Uninstalled dishwasher and removed drain pump assembly. Installed new replacement. Installed rinse aid cap. Reassembled. Tested unit. Unit now fills,washes drain and heats as intended. All water connections were dry at time of service.
Near San Marcos, Texas 78666
Derek S.
Job Details: 10/02/2018
AGR5330BAS2 Arrived on site and replaced the valve due to mechanical failure, verified operations, no gas leak present at the time of service
Near San Marcos, Texas 78666
Derek S.
Job Details: 10/02/2018
AGR5330BAS2 Arrived on site and replaced the valve due to mechanical failure, verified operations, no gas leak present at the time of service
We serviced a
Arrived on site for glass shattered in fresh food and in freezer compartment. Found all glass shelves in fresh food section shattered and broken. Found on the right inside Liner wall a small gouge. All fresh food section parts will have to be replaced due Dustin gave me an SR# but I accidentally deleted it while typing my notes. However the SR# is in Whirlpools file.
Model All water connections were dry.
Near Bastrop, Texas 78602
Thomas L.
Job Details: 10/02/2018
Near Leander, Texas 78641
Lou
Job Details: 10/02/2018
arrived on site to inspect washer stopping mid cycle. Upon further inspection, I placed the unit in diagnostics and tested. The unit showed error code F8E1-long fill, no fill. I cleared the code and continued with testing. The unit operated as designed with no error codes at the end of testing. At this time, I cannot find anything mechanically wrong with the unit. I provided recommendations to the customer on use ad care of the washer. No water leaks observed during service, job completed.
Near Austin, Texas 78717
Tyler B.
Job Details: 10/02/2018
Near Leander, Texas 78641
Lou
Job Details: 10/02/2018
arrived one site to inspect cooktop burner not working. Upon further inspection, i tested all of the burners and found that the right rear burner not heating up. After inspecting the burner even further, I found that the wiring connector was loose. I adjusted the connector and tightened it and tested the burner and it operated as designed. Job completed.
Near Manor, Texas 78653
Wesley
Job Details: 10/02/2018
Arrived on site and found unit control broken. Replaced control. All checks good. Now unit is operating as designed.
Near New Braunfels, Texas 78132
Derek S.
Job Details: 10/02/2018
WFE515S0ES1 Arrived on site to repair unit for low temps. I found the temp was out of range was averaging 320 at 350: replaced the control and sensor due to out of spec, unit is now working as designed.
Near New Braunfels, Texas 78132
Derek S.
Job Details: 10/02/2018
WFE515S0ES1 Arrived on site to repair unit for low temps. I found the temp was out of range was averaging 320 at 350: replaced the control and sensor due to out of spec, unit is now working as designed.
Near Austin, Texas 78717
Tyler B.
Job Details: 10/02/2018
Near Waco, Texas 76708
Arthur B.
Job Details: 10/02/2018
MEDB765FW0 (Dryer) - Arrived onsite for customer complaint of door popping open when running. Was able to adjust bottom door hinges. Installed new strike and door catch. Tested door. Door now closes and stays closed during cycle.
Near Bastrop, Texas 78602
Thomas L.
Job Details: 10/02/2018
Arrived on site for no cool condition. Found fresh food section at 37.6 and freezer was at 9 degrees. Unit functioning properly. All water connections were dry
Near Austin, Texas 78717
Tyler B.
Job Details: 10/02/2018
Near Georgetown, Texas 78626
Jonathan S
Job Details: 10/02/2018
GE dishwasher model# GLD4260L00SS. Arrived on site for dishwasher leaking water all around dishwash
Near Waco, Texas 76710
Arthur B.
Job Details: 10/02/2018
WDF540PADW1 (Dishwasher) - Arrived onsite to install new control and OWI sensor to dishwasher from prior tech’s diagnosis. Removed control and OWI sensor and installed new replacement. Reassembled. Tested unit. Unit now fills,washes,drain and heats as intended. All water connections were dry at time of service.
Near Austin, Texas 78753
Wesley
Job Details: 10/02/2018
Arrived on site and found unit operating as designed no smell. Recommended cleaning procedures as regular part of maintenance. And reduced soap usage. All else checks good. No leaks at time of service.
Near Bastrop, Texas 78602
Thomas L.
Job Details: 10/02/2018
Arrived on site, checked freezer. There was ice build up inside the cabin floor. Found drain tube defective. Replaced drain tube. All water connections were dry.
Near Woodway, Texas 76712
Arthur B.
Job Details: 10/02/2018
WED8500DC0 (Dryer) - Arrived onsite for customer complaint of dryer making loud screeching noise when tumbling. Removed bulkhead and found nail grinding in blower wheel area. Removed obstruction and reassembled. Dryer now tumbles quietly. No other issues found. Dryer vent and lint trap was clean of lint at time of service.
Near Austin, Texas 78703
Scott
Job Details: 10/02/2018
Kitchen aid dishwasher , not drying properly
Near Bastrop, Texas 78602
Thomas L.
Job Details: 10/02/2018
Arrived on site for no cool condition in freezer. Found 3 way refrigerant valve was stuck in the fresh food position and would not move to freezer position. Replaced valve. Defrosted fresh food evaporator with steamer. Watched system function in Step 4 of diagnostics. All systems worked correctly. All water connections were dry.
Near Austin, Texas 78753
Wesley
Job Details: 10/02/2018
Arrived on site and replaced switch harness to repair sparking. Unit is now operating as designed. Advised customer on repair.
Near Austin, Texas 78753
Wesley
Job Details: 10/02/2018
Arrived on site to inspect poor washing symptom and low water. No error codes. Valves operating properly. All else passes inspection. Advised customer on unit design. Water connections dry.
Near Waco, Texas 76712
Arthur B.
Job Details: 10/02/2018
WRF954CIHZ00 (French Door Refrigerator) - Arrived onsite for customer complaint of french door refrigerator not dispensing water. Found solenoid on water valve not opening. Removed and replace water valve. Reassembled. Tested unit. Unit now dispenses water as intended. All water connections were dry at time of service
Near Austin, Texas 78739
Brandon
Job Details: 10/02/2018
Arrived on site for customer complaint of unit not starting. I found bad thermal fuse, replaced fuse, unit tested good. Instructed customer to have vent cleaned.
Near Taylor, Texas 76574
Wesley
Job Details: 10/01/2018
Arrived on site and installed fuse and 3 prong switch to repair short in switch. And blown fuse. Unit is now operating as designed.
Near Killeen, Texas 76543
Arthur B.
Job Details: 10/01/2018
MVWB450WQ0 (Too Load a Washer) - Arrived onsite for customer complaint of top load washer leaking from bottom rear when washing. Lifted top and found leak coming from bleach dispenser. P&L are as follows; WPW10187307 (Bleach Dispenser) $70.00,TL290 $189.99 plus tax. Collected SVC fee today. Customer wrote check for $99.00 but forgot to add taxes. Customer will settle on return. R/S for Friday 10/5 12P-5P. All water connections were dry at time of service.
Near New Braunfels, Texas 78132
Derek S.
Job Details: 10/01/2018
KSRL25FTSS01 Arrived on site to repair unit for no ice, i verified that the optical board was working as designed, found icemaker defective electrical failure in module, replaced the icemaker and it filled with water, verified no water leak present at the time of service
Near New Braunfels, Texas 78132
Derek S.
Job Details: 10/01/2018
KSRL25FTSS01 Arrived on site to repair unit for no ice, i verified that the optical board was working as designed, found icemaker defective electrical failure in module, replaced the icemaker and it filled with water, verified no water leak present at the time of service
Near Round Rock, Texas 78681
Tyler B.
Job Details: 10/01/2018
Near Austin, Texas 78748
Brandon
Job Details: 10/01/2018
Arrived on site for customer complaint of noise issue, found bad roller wheel, I replaced dryer repair kit, unit tested good.
Near Cedar Park, Texas 78613
Tyler B.
Job Details: 10/01/2018
Near Round Rock, Texas 78664
Tyler B.
Job Details: 10/01/2018
Near Hutto, Texas 78634
Wesley
Job Details: 10/01/2018
Arrived on site and installed catch due to door not staying latched. Found deformity with cabinet panel preventing proper latching. Ordering panel and strike to repair.
Near Round Rock, Texas 78665
Tyler B.
Job Details: 10/01/2018
Near Cedar Park, Texas 78613
Lou
Job Details: 10/01/2018
arrived on site to inspect dishwasher rack broken. Upon further inspection, I found that the right upper rack track had come apart and the left upper rack track was bent. I removed and replaced cos and tested the unit and the unit operated as designed. No water leaks observed during service, job completed.
Near Killeen, Texas 76549
Arthur B.
Job Details: 10/01/2018
WF337AAGXA (Front Load a Washer) - Arrived onsite to remove and replace water valve dispenser assembly from prior visit’s diagnosis. Removed assembly and installed new replacement. Reassembled. Tested unit. Found no leaking coming from new assembly. All water connections were dry at time of service.
Near Austin, Texas 78732
Cliff
Job Details: 10/01/2018
Whirlpool range WEE510S0FS1. Arrived on site to diagnose a range that is not responding to controls. Found control shorted out causing unit not to respond to user input. Replaced control and tested unit. Found all is working properly at this time.
Near Round Rock, Texas 78665
Wesley
Job Details: 10/01/2018
Arrived on site and replaced pad. All checks good. Unit is now operating as designed. Water connections dry.
Near Manor, Texas 78653
Joseph C.
Job Details: 10/01/2018
WMH53521HZ3 Arrived on site for “microwave hood light not working” complaint. Inspected unit and found faulty control blew out lamp socket. Removed and replaced control and lamp socket. Unit tests good.
Near Georgetown, Texas 78626
Tyler B.
Job Details: 10/01/2018
Near Canyon Lake, Texas 78133
Derek S.
Job Details: 10/01/2018
PYET244AYW Arrived on site and replaced the timer due to unit no heating at the 20min mark timed dry, verified unit is now heating at the 20 min mark. Dryer and duct free of lint at the time of service
Near Canyon Lake, Texas 78133
Derek S.
Job Details: 10/01/2018
PYET244AYW Arrived on site and replaced the timer due to unit no heating at the 20min mark timed dry, verified unit is now heating at the 20 min mark. Dryer and duct free of lint at the time of service
Near Georgetown, Texas 78626
Tyler B.
Job Details: 10/01/2018
Near Austin, Texas 78727
Wesley
Job Details: 10/01/2018
Arrived on site and removed drain plug from disposal to allow DW to function and drain. All checks good.
Near Austin, Texas 78754
Joseph C.
Job Details: 10/01/2018
KSEG950ESS1 Arrived on site for “noisy clicking, during operation” complaint. Inspected unit and found bent shaft on convection fan. Removed and replaced convection fan. Tested unit and found to be operating properly.
Near Georgetown, Texas 78628
Lou
Job Details: 10/01/2018
arrived on site to inspect cooktop making clicking sound after ignition. Upon further inspection, after plugging the unit back in, I found that the front left valve was stuck and causing the Ignitor to constantly arc. I attempted to pull the valve knob stem out, but could not. Also found that the grates are warped and the inner front rubber feet on both grates do not touch the cooktop surface. I am ordering both grates, front left valve, and the cooktop. I am ordering the cooktop due to it possibly being warped but will test the new grates before installing the cooktop. I scheduled return service for 10/8/18. No gas leaks observed during service.
Near New Braunfels, Texas 78132
Derek S.
Job Details: 10/01/2018
WOD93EC0AS05 Arrived on site and replaced the control panel due to bubble cosmetic damage, verified operations,
Near New Braunfels, Texas 78132
Derek S.
Job Details: 10/01/2018
WOD93EC0AS05 Arrived on site and replaced the control panel due to bubble cosmetic damage, verified operations,
Near Austin, Texas 78749
Kevin
Job Details: 10/01/2018
Arrived on site and replaced all suspension found broken on previous visit, Replaced heater connection and reattached harness to heater and it is now operating properly. Ran a test diagnostic cycle and completed properly, no water leaks from connections at time of service, job complete
Near Lampasas, Texas 76550
Arthur B.
Job Details: 10/01/2018
JB860DJ5WW (Freestanding Range) - Arrived onsite for customer complaint of freestanding range light not coming on in upper oven. Removed back panel and found relay board shorted causing light not to come on. Ordering new relay board to complete repair. R/S for 10/4.
Near Georgetown, Texas 78628
Tyler B.
Job Details: 10/01/2018
Near Lampasas, Texas 76550
Arthur B.
Job Details: 10/01/2018
MVWC416FW1 (Top Load Washer) - Arrived onsite for customer complaint of top load washer not spinning out clothes. Ran diagnostics and found error code F7E7 (Motor Fault). Tilted unit up and found motor had a burnt smell. Removed and replaced motor. Reassembled. Calibrated unit. Unit calibrated successfully. Unit now fills,agitates,drain and spins as intended. All water connections were dry at time of service.
Near Georgetown, Texas 78628
Lou
Job Details: 10/01/2018
arrived on site to inspect dishwasher kick plate not secured. Upon further inspection, I found that the ick plate retainers were missing. I installed two retainers and tested the unit and the unit operates as designed. No water leaks observed during service, job completed.
Near Austin, Texas 78732
Chase
Job Details: 09/28/2018
KDTE704DSS Arrived on site. Checked dishwasher for no operation. Found control panel not responding at all and drain pump running but not moving water. Replaced console and found drain pump impeller broken due to debris stuck in pump. Replaced drain pump and tested unit. All functions of dishwasher check good after repair, no water leaks present
Near Kyle, Texas 78640
Derek S.
Job Details: 09/28/2018
KRMF706ESS Arrived on site to repair unit for noise in freezer section when closing the door, I found a rivot broke off of the left bracket and bent the shaft, I replaced the rivot and replaced the shaft, Mr Barr’s informed that he is not happy that the cabinet is not level and is going to try to swap unit with his dealer, no water leak present at the time of service, see notes