Near Cedar Park, Texas 78613
Lou
Job Details: 10/01/2018
arrived on site to inspect dishwasher rack broken. Upon further inspection, I found that the right upper rack track had come apart and the left upper rack track was bent. I removed and replaced cos and tested the unit and the unit operated as designed. No water leaks observed during service, job completed.
Near Killeen, Texas 76549
Arthur B.
Job Details: 10/01/2018
WF337AAGXA (Front Load a Washer) - Arrived onsite to remove and replace water valve dispenser assembly from prior visit’s diagnosis. Removed assembly and installed new replacement. Reassembled. Tested unit. Found no leaking coming from new assembly. All water connections were dry at time of service.
Near Austin, Texas 78732
Cliff
Job Details: 10/01/2018
Whirlpool range WEE510S0FS1. Arrived on site to diagnose a range that is not responding to controls. Found control shorted out causing unit not to respond to user input. Replaced control and tested unit. Found all is working properly at this time.
Near Round Rock, Texas 78665
Wesley
Job Details: 10/01/2018
Arrived on site and replaced pad. All checks good. Unit is now operating as designed. Water connections dry.
Near Manor, Texas 78653
Joseph C.
Job Details: 10/01/2018
WMH53521HZ3 Arrived on site for “microwave hood light not working” complaint. Inspected unit and found faulty control blew out lamp socket. Removed and replaced control and lamp socket. Unit tests good.
Near Georgetown, Texas 78626
Tyler B.
Job Details: 10/01/2018
Near Canyon Lake, Texas 78133
Derek S.
Job Details: 10/01/2018
PYET244AYW Arrived on site and replaced the timer due to unit no heating at the 20min mark timed dry, verified unit is now heating at the 20 min mark. Dryer and duct free of lint at the time of service
Near Canyon Lake, Texas 78133
Derek S.
Job Details: 10/01/2018
PYET244AYW Arrived on site and replaced the timer due to unit no heating at the 20min mark timed dry, verified unit is now heating at the 20 min mark. Dryer and duct free of lint at the time of service
Near Georgetown, Texas 78626
Tyler B.
Job Details: 10/01/2018
Near Austin, Texas 78727
Wesley
Job Details: 10/01/2018
Arrived on site and removed drain plug from disposal to allow DW to function and drain. All checks good.
Near Austin, Texas 78754
Joseph C.
Job Details: 10/01/2018
KSEG950ESS1 Arrived on site for “noisy clicking, during operation” complaint. Inspected unit and found bent shaft on convection fan. Removed and replaced convection fan. Tested unit and found to be operating properly.
Near Georgetown, Texas 78628
Lou
Job Details: 10/01/2018
arrived on site to inspect cooktop making clicking sound after ignition. Upon further inspection, after plugging the unit back in, I found that the front left valve was stuck and causing the Ignitor to constantly arc. I attempted to pull the valve knob stem out, but could not. Also found that the grates are warped and the inner front rubber feet on both grates do not touch the cooktop surface. I am ordering both grates, front left valve, and the cooktop. I am ordering the cooktop due to it possibly being warped but will test the new grates before installing the cooktop. I scheduled return service for 10/8/18. No gas leaks observed during service.
Near New Braunfels, Texas 78132
Derek S.
Job Details: 10/01/2018
WOD93EC0AS05 Arrived on site and replaced the control panel due to bubble cosmetic damage, verified operations,
Near New Braunfels, Texas 78132
Derek S.
Job Details: 10/01/2018
WOD93EC0AS05 Arrived on site and replaced the control panel due to bubble cosmetic damage, verified operations,
Near Austin, Texas 78749
Kevin
Job Details: 10/01/2018
Arrived on site and replaced all suspension found broken on previous visit, Replaced heater connection and reattached harness to heater and it is now operating properly. Ran a test diagnostic cycle and completed properly, no water leaks from connections at time of service, job complete
Near Lampasas, Texas 76550
Arthur B.
Job Details: 10/01/2018
JB860DJ5WW (Freestanding Range) - Arrived onsite for customer complaint of freestanding range light not coming on in upper oven. Removed back panel and found relay board shorted causing light not to come on. Ordering new relay board to complete repair. R/S for 10/4.
Near Georgetown, Texas 78628
Tyler B.
Job Details: 10/01/2018
Near Lampasas, Texas 76550
Arthur B.
Job Details: 10/01/2018
MVWC416FW1 (Top Load Washer) - Arrived onsite for customer complaint of top load washer not spinning out clothes. Ran diagnostics and found error code F7E7 (Motor Fault). Tilted unit up and found motor had a burnt smell. Removed and replaced motor. Reassembled. Calibrated unit. Unit calibrated successfully. Unit now fills,agitates,drain and spins as intended. All water connections were dry at time of service.
Near Georgetown, Texas 78628
Lou
Job Details: 10/01/2018
arrived on site to inspect dishwasher kick plate not secured. Upon further inspection, I found that the ick plate retainers were missing. I installed two retainers and tested the unit and the unit operates as designed. No water leaks observed during service, job completed.
Near Austin, Texas 78732
Chase
Job Details: 09/28/2018
KDTE704DSS Arrived on site. Checked dishwasher for no operation. Found control panel not responding at all and drain pump running but not moving water. Replaced console and found drain pump impeller broken due to debris stuck in pump. Replaced drain pump and tested unit. All functions of dishwasher check good after repair, no water leaks present
Near Kyle, Texas 78640
Derek S.
Job Details: 09/28/2018
KRMF706ESS Arrived on site to repair unit for noise in freezer section when closing the door, I found a rivot broke off of the left bracket and bent the shaft, I replaced the rivot and replaced the shaft, Mr Barr’s informed that he is not happy that the cabinet is not level and is going to try to swap unit with his dealer, no water leak present at the time of service, see notes
Near Kyle, Texas 78640
Derek S.
Job Details: 09/28/2018
KRMF706ESS Arrived on site to repair unit for noise in freezer section when closing the door, I found a rivot broke off of the left bracket and bent the shaft, I replaced the rivot and replaced the shaft, Mr Barr’s informed that he is not happy that the cabinet is not level and is going to try to swap unit with his dealer, no water leak present at the time of service, see notes
Near Lampasas, Texas 76550
Arthur B.
Job Details: 09/28/2018
MVWC415EW1 (Top Load Washer) - Arrived onsite for customer complaint of top load washer not spinning or agitating. Tilted unit up and found capacitor faulty. P&L are as follows;W11158831 (Capacitor) $127.16,TL150 $169.99 plus taxes. Removed and replaced capacitor. Reassembled and calibrated unit. Unit completed successfully. Unit now fills,agitates,drain and spins as intended. No other issues found. All water connections were dry at time of service.
Near Elgin, Texas 78621
Wesley
Job Details: 09/28/2018
Arrived on site and found no rattling at time of service, sounded like condenser rattle. Heat treated all seals and checked temps. All looks good. unit is operating as designed after seal repair. Adjusted ice cube size. No leaks at time of service.
Near Georgetown, Texas 78628
Thomas L.
Job Details: 09/28/2018
Arrived on site, checked unit. Fresh food cabinet was not cooling. Found fan in fresh food section has failed. Defrosted and replaced. All water connections were dry. Had no internet connection so Erica ran card and it was approved.
Near Pflugerville, Texas 78660
Tyler B.
Job Details: 09/28/2018
Near Pflugerville, Texas 78660
Tyler B.
Job Details: 09/28/2018
Near Lampasas, Texas 76550
Arthur B.
Job Details: 09/28/2018
WTW5000DW0 (Top Load Washer) - Arrived onsite to install new gearcase to top load washer from prior tech’s diagnosis. Removed gearcase and installed new replacement. Installed new washplate. Reassembled. Calibrated unit. Unit calibrated as intended. Unit now fills,agitates,drain and spins as intended. All water connections were dry at time of service.
Near Taylor, Texas 76574
Wesley
Job Details: 09/28/2018
Arrived on site and found unit operating as designed. Slow leaky valve. Replaced leaky valve. No leaks at time of service, all checks good. Unit operating as designed.
Near Taylor, Texas 76574
Wesley
Job Details: 09/28/2018
Ari ed on site and found unit operating as designed with broken latch. Replaced door latch. Now everything checks good.
Near Pflugerville, Texas 78660
Tyler B.
Job Details: 09/28/2018
Near Georgetown, Texas 78633
Lou
Job Details: 09/28/2018
arrived inside site to inspect oven making noises. Upon arrival, the customer explained that when they Bake at 400 degrees the oven makes loud popping noises and other loud noises. Also, they advised that the inspector said the bottom oven was 70 degrees too high. Upon further inspection, using my thermalcouple, I placed my lead in the middle of the center rack and began testing on Bake at 350 degrees. I turned the top oven on to see if I could hear the noises the customer is concerned about. Once the bottom oven beeped at 350 preheat my reading was 407. My next four readings were 307, 376, 318, and 377 for an average of 357. With these readings I believe that the unit is operating as designed. I did find in the top oven that the gasket was not seated correctly. There were two pins that were not pressed into the chassis which could potentially cause airflow too leak out. I reseated the gasket and made sure it was seating correctly. Job completed.
Near Killeen, Texas 76549
Arthur B.
Job Details: 09/28/2018
WTW8040DW4 (Top Load Washer) - Arrived onsite for customer complaint of top load washer not draining. Found tub was full of water. Removed water and removed drain pump. Found drain pump faulty. Replaced drain pump. Reassembled. Cleared error codes and ran test 052. Unit completed successfully. Unit now fills,agitates,drain and spins as intended. All water connections were dry at time of service..
Near Austin, Texas 78728
Cliff
Job Details: 09/28/2018
Whirlpool dishwasher WDT710PAHZ1. Arrived on site to diagnose a dishwasher that is not drying properly. Tested unit and found no mechanical failures to dishwasher at this time. Did note homeowner has no rinse agent in dispenser. Advised homeowner on best cycles and options to use for best performance as well as necessity of using rinse agent for proper drying. No further repairs are needed at this time and no leaks were found at time of service.
Near Pflugerville, Texas 78660
Tyler B.
Job Details: 09/28/2018
Near Taylor, Texas 76574
Wesley
Job Details: 09/28/2018
Arrived on site and found unit operating with too much sudsing. Stopping occasionally to drain mid cycle. Advised customer that errors are related to soap usage. Reset control and tested. No leaks. Cleared air hose for proper reading all checks good. After repair.
Near Round Mountain, Texas 78663
Thomas L.
Job Details: 09/28/2018
Arrived on site, checked unit. Dispenser is functioning irregularly. Removed and replaced dispenser. Properly fastened and wired. Fastened drain hose. Tested washer, unit working properly at this time. All water connections were dry.
Near Killeen, Texas 76549
Arthur B.
Job Details: 09/28/2018
WFW9400SB00 (Front Load Washer) - Arrived onsite for customer complaint of front load washer leaking when in use. Found bellow all torn around door. Removed and replace bellow. Reassembled. Tested unit. Unit now fills,agitates,drain and spins with no issues or leaks. All water connections were dry at time of service.
Near Georgetown, Texas 78633
Lou
Job Details: 09/28/2018
arrived one site to inspect refrigerator not dispensing water. Upon further inspection, I removed the water filter and tested the water dispenser and the unit dispenser water. Also while I had the rc door open, the diffuser came on and was very loud. I quoted the customer RF270 $169.99 for diagnosis/labor to replace the housing, $98.32 for the filter housing, and $59.92 for the diffuser for a total including tax of $355.31. The customer agreed to the repair of the housing for today and will pay the balance for the diffuser at next service call. Customer paid $290.45 and the remaining balance will be $64.86 (no labor cost on return service-already figured in). I removed and replaced the filter housing and tested the unit and it operated as designed. I am ordering a diffuser and scheduled return service for 10/02/18. No water leaks observed during service.
Near Hutto, Texas 78634
Wesley
Job Details: 09/28/2018
Arrived on site and found unit icemaker shorted. Replaced icemaker. Unit now operating as designed. No leaks a time of service.
Near Round Rock, Texas 78665
Jonathan S
Job Details: 09/28/2018
GE microwave model# PEB7226SF2SS. Losing power intermittently and now no power
Near Pflugerville, Texas 78660
Wesley
Job Details: 09/28/2018
Arrived on site and found rinseaid dispenser not dispensing. Ordering dispenser to repair. No leaks.
Near Pflugerville, Texas 78660
Wesley
Job Details: 09/28/2018
Arrived onsite and found door liner peeling. Replaced door glass. All checks good, unit now operating properly. No leaks detected.
Near Pflugerville, Texas 78660
Tyler B.
Job Details: 09/28/2018
Near Seguin, Texas 78155
Derek S.
Job Details: 09/28/2018
WTW5000DW2 Arrived on site to check unit for not adding enough water, I ran service test and unit had zero error codes, I informed Mrs to use cycle bulky for best wash performance and I demonstrated that basket will fill halfway when using bulky, gave tips for best wash performance,unit is working as designed, no water leak present at the time of service
Near Seguin, Texas 78155
Derek S.
Job Details: 09/28/2018
WTW5000DW2 Arrived on site to check unit for not adding enough water, I ran service test and unit had zero error codes, I informed Mrs to use cycle bulky for best wash performance and I demonstrated that basket will fill halfway when using bulky, gave tips for best wash performance,unit is working as designed, no water leak present at the time of service
Near Georgetown, Texas 78633
Lou
Job Details: 09/28/2018
arrived on site to inspect microwave door misaligned. Upon further inspection, the customer advised that he placed a wedge in between the unit door and the wall to keep the door from opening during travels (unit in a travel camper). I found that the bottom door hinge was slightly bent causing the door to rub against the chassis. I removed the door to examine the hinge and due to the hinge not being available, I used a pair of pliers and adjusted the hinge and re-installed the door and tested. The door opened and closed as designed. Job completed.
Near Killeen, Texas 76542
Arthur B.
Job Details: 09/28/2018
WRS325SDHZ00 (SxS Refrigerator) - Arrived onsite for customer complaint of SxS getting ice build up on FC side. Found ice build up on upper LH corner of RC door. Found corner warped and tore the gasket. Ordering new FC door to complete repair. Advised door will take 6-8 weeks. OF to R/S. All water connections were dry at time of service.
Near Pflugerville, Texas 78660
Wesley
Job Details: 09/28/2018
Arrived on site and found icemaker not filling but valve actuating. Returning with valve and control. No leaks at time of service. No frozen lines.
Near Killeen, Texas 76542
Arthur B.
Job Details: 09/28/2018
GI6FARXXB06 (French Door Refrigerator) - Arrived onsite for customer complaint of water leaking from bottom of french door refrigerator. Removed door and found sheet of ice on bottom. Used steamer to remove all ice from drain channel and under evaporator. Water now flows well to drain hole. No other issues found. All water connections were dry at time of service.
Near Austin, Texas 78731
Luis
Job Details: 09/28/2018
Built in kitchenAid-frozen drain in freezer defrosted drain checked water flow good.
Near Georgetown, Texas 78633
Lou
Job Details: 09/28/2018
arrived on site to install previously diagnosed and ordered part. I removed and replaced the sump/motor assembly and tested the unit. Unit operated as designed with no error codes at the end of testing. No water leaks observed during service, job completed.
Near San Marcos, Texas 78666
Derek S.
Job Details: 09/28/2018
KMHS120ESS5 Arrived on site to repair unit for burnt mark after top rack sparked in unit, I replaced the supports due to black marks and added touch up paint to cavity, instructed Mrs Lopez to only use the rack while dual cooking on both levels otherwise sparks will occur, unit working as designed.
Near San Marcos, Texas 78666
Derek S.
Job Details: 09/28/2018
KMHS120ESS5 Arrived on site to repair unit for burnt mark after top rack sparked in unit, I replaced the supports due to black marks and added touch up paint to cavity, instructed Mrs Lopez to only use the rack while dual cooking on both levels otherwise sparks will occur, unit working as designed.
Near New Braunfels, Texas 78130
Derek S.
Job Details: 09/27/2018
WED4815EW Arrived on site to repair unit from getting black residue on clothing, I found black rubber was on the drum slides and bulkhead, I was able to remove all the rubber by cleaning, verified all rubber is off, dryer and duct free of lint at the time of service
Near New Braunfels, Texas 78130
Derek S.
Job Details: 09/27/2018
WED4815EW Arrived on site to repair unit from getting black residue on clothing, I found black rubber was on the drum slides and bulkhead, I was able to remove all the rubber by cleaning, verified all rubber is off, dryer and duct free of lint at the time of service
Near Round Rock, Texas 78665
Wesley
Job Details: 09/27/2018
Arrived on site and found unit had proper voltage. No operation of lights or motor. Ordering power cord and capacitor and control. Customer time constraint.
Near New Braunfels, Texas 78130
Derek S.
Job Details: 09/27/2018
WDT970SAHZ0 arrived on site to repair unit for not washing, I found the wash motor was defective, replaced the sump and verified operations with no issues. No water leak present at the time of service
Near New Braunfels, Texas 78130
Derek S.
Job Details: 09/27/2018
WDT970SAHZ0 arrived on site to repair unit for not washing, I found the wash motor was defective, replaced the sump and verified operations with no issues. No water leak present at the time of service
Near Austin, Texas 78727
Cliff
Job Details: 09/27/2018
Kenmore refrigerator 79572063112. Arrived on site to diagnose a refrigerator with a screw that had fallen out of ice dispenser. I found missing screw had come from latch stop assembly on ice room door. Reinstalled stop assembly with longer screw to prevent future failure. No other repairs are needed at this time and all is working properly. No leaks were found at time of service.
Near Austin, Texas 78728
Wesley
Job Details: 09/27/2018
Arrived on site and repaired by clearing ff Evap drain of ice and verifying good drain action. Dryed all melted ice. All checks good. Unit is now operating as designed. All checks good.
Near Bastrop, Texas 78602
Thomas L.
Job Details: 09/27/2018
Arrived on site for no bake condition. Found unit to have a failed bake igniter. Replaced igniter. Tested unit. Bake now works properly.
Near Seguin, Texas 78155
Derek S.
Job Details: 09/27/2018
KDFE104DSS5 Arrived on site to repair unit for not draining, I found the drain pump was damaged due to mechanical failure, replaced the drain pump and verified drain operation three separate times, no water leak present at the time of service
Near Seguin, Texas 78155
Derek S.
Job Details: 09/27/2018
KDFE104DSS5 Arrived on site to repair unit for not draining, I found the drain pump was damaged due to mechanical failure, replaced the drain pump and verified drain operation three separate times, no water leak present at the time of service
Near Leander, Texas 78641
Lou
Job Details: 09/27/2018
arrived on site to inspect range broken light. Upon further inspection, I found that the range oven light bulb broke and the base was stuck in the housing. I unplugged the unit and using a pair of pliers I was able to remove the base from the housing and install a new bulb which was covered by an EPL1. I turned the light on and the bulb worked as designed. No gas leaks detected during service, job completed.
Near Austin, Texas 78731
Cliff
Job Details: 09/27/2018
Whirlpool microwave WMH31017FB0. Arrived on site to replace previously ordered parts. Replaced thermistor and found control was not needed. Informed homeowner on automatic fan function as microwave bottom gets warm. No other repairs are needed at this time and all is working properly.
Near Temple, Texas 76502
Arthur B.
Job Details: 09/27/2018
WRS325FDAM04 (SxS Refrigerator) - Arrived onsite to install new LED modules in both RC and FC section of SxS refrigerator from prior tech’s diagnosis. Removed all LEDs and installed new replacements. Found now all lights illuminate. No other issues found. All water connections were dry at time of service.
Near Pflugerville, Texas 78660
Wesley
Job Details: 09/27/2018
Arrived onsite and used tape and Evap cover and thermistor kit to repair Evap freezing problem according to techline instructions. All checks good. Unit is now operating as designed. No leaks at time of service.
Near Belton, Texas 76513
Arthur B.
Job Details: 09/27/2018
WRX988SIBM01 (French Door Refrigerator) - Arrived onsite for customer complaint of no cool in RC section of french door refrigerator. When arrived, Both RC and FC sections are cooling properly and ice bin full. Did find that UI on deli drawer is shorted causing misreading to control. Ordering new UI deli drawer control to complete repair. R/S for Monday 10/1. All water connections were dry at time of service.
Near Leander, Texas 78641
Lou
Job Details: 09/27/2018
arrived on site to inspect refrigerator lights blinking off and on. Upon further inspection, I found that the lights on the waterbox cover were not working and neither was the light in the freezer section. I removed the waterbox cover to inspect the light connections and all was good. I pulled the unit from its space and removed and replaced the LED control and opened the rc doors and all of the lights came on as did the light in the fc section. No water leaks observed during service, job completed.
Near Austin, Texas 78717
Tyler B.
Job Details: 09/27/2018
Near Austin, Texas 78723
Robert
Job Details: 09/27/2018
WMH31017FB0 Arrived on job for complaints of light flickers. Confirmed light not always coming on or off. Replaced all three switches and holders. Test operation.
Near Harker Heights, Texas 76548
Arthur B.
Job Details: 09/27/2018
WMH73521CS6 (OTR Microwave) - Arrived onsite for customer complaint of OTR microwave getting “OPEN/CLOSE” door error intermittently. Tested unit and found open close error. Removed and replaced 3Way,NC,NO switches along with interlocks. Reassembled. Tested unit multiple times. Unit does no longer shows error. No other issues found.
Near Seguin, Texas 78155
Derek S.
Job Details: 09/27/2018
WDT720PADM1 arrived on site to repair unit for e2 error, found that the user interface panel was shorted and subsequently shorted the main control, replaced interface panel and main control and verified all operations with no issues, no water leak present at the time of service
Near Seguin, Texas 78155
Derek S.
Job Details: 09/27/2018
WDT720PADM1 arrived on site to repair unit for e2 error, found that the user interface panel was shorted and subsequently shorted the main control, replaced interface panel and main control and verified all operations with no issues, no water leak present at the time of service
Near Seguin, Texas 78155
Derek S.
Job Details: 09/27/2018
WDT720PADM1 arrived on site to repair unit for e2 error, found that the user interface panel was shorted and subsequently shorted the main control, replaced interface panel and main control and verified all operations with no issues, no water leak present at the time of service
Near Seguin, Texas 78155
Derek S.
Job Details: 09/27/2018
WDT720PADM1 arrived on site to repair unit for e2 error, found that the user interface panel was shorted and subsequently shorted the main control, replaced interface panel and main control and verified all operations with no issues, no water leak present at the time of service
Near Austin, Texas 78759
Cliff
Job Details: 09/27/2018
Whirlpool refrigerator ED5NHGXVQ01. Arrived on site to diagnose a refrigerator that will not dispense ice. Tested unit and found bracket for the dispenser switches is broken. Replaced bracket and tested unit. Found all is functioning properly at this time. No leaks were found at time of service.
Near Hutto, Texas 78634
Wesley
Job Details: 09/27/2018
Arrived on site and found unit ff Evap frozen over. Found ff damper control cycling continuously. Found Evap cover tabs broken. Ordering Evap cover and damper and returning with harness to repair, unit not completely thawed at time of service, area dry at time of service.
Near Copperas Cove, Texas 76522
Arthur B.
Job Details: 09/27/2018
WZF79R20DW00 (Freestanding Range) - Arrived onsite for customer complaint of upright freezer not cooling. When arrived,food was still inside unit. Attempted to shut control off. Control will not respond. Unit will need control assembly. Returning with start device just incase. R/S for 10/1. Customer will have unit cleaned out before return. Unit is disconnected from power at this time.
Near Austin, Texas 78703
Robert
Job Details: 09/27/2018
WRF550CDHZ00 Arrived on job for complaints of frost in freezer. Found the back wall frosty. Removed frost from coils and replaced evap motor that included sensor, heater test good. No leaks
Near Austin, Texas 78717
Lou
Job Details: 09/27/2018
arrived on site to inspect dryer making noises. Upon further inspection, the customer turned the unit on with towels inside the drum and the unit immediately began to squeal and squeak. I quoted the customer DR120 $70.00 for labor and $57.83 for a dryer kit for a total including tax of $138.38. Customer agreed to the repair and paid in full. I removed and replaced the rollers, tension roller, and belt ad tested the unit. The unit operated as designed, cleaned lint from the unit. Job completed.
Near Cedar Park, Texas 78613
Lou
Job Details: 09/27/2018
arrived on site to inspect cooktop knob not turning. Upon further inspection, I tested the unit by turning the knob and found it hard to turn. I opened up the cooktop to be able to inspect the valve and found that it was slightly bent on the shaft of the valve. I removed and replaced the valve and tested and the knob/valve is much easier to turn. Using my liquid gas detector, I checked all gas connections to the cooktop and detected no gas leaks. Job completed.
Near Bastrop, Texas 78602
Scott
Job Details: 09/27/2018
Whirlpool top load clothes washer, correct drain hose
Near San Marcos, Texas 78666
Derek S.
Job Details: 09/27/2018
KTRP22EKWH02 Arrived on site to repair unit for leaking water into fridge, I found the freezer drain tube was clogged, I cleared out all the ice in freezer and cleared the drain tube, verified poor in hot water down drain tube, no water leak present at the time of service
Near San Marcos, Texas 78666
Derek S.
Job Details: 09/27/2018
KTRP22EKWH02 Arrived on site to repair unit for leaking water into fridge, I found the freezer drain tube was clogged, I cleared out all the ice in freezer and cleared the drain tube, verified poor in hot water down drain tube, no water leak present at the time of service
Near Pflugerville, Texas 78660
Wesley
Job Details: 09/27/2018
Arrived on site and replaced broken ignition knob. All checks good,
Near Kempner, Texas 76539
Arthur B.
Job Details: 09/27/2018
RB787CH2CC (Freestanding) - Arrived onsite for customer complaint of freestanding oven not heating properly. When arrived, unit was preheated but found relay in control would not cycle to maintain heat. Unit will need new control,overlay and sensor to complete repair. R/S for 10/3. No other issues found.
Near San Marcos, Texas 78666
Derek S.
Job Details: 09/27/2018
WFG505M0BS3 Arrived on site to repair unit for f3 error, I found that the sensor was out of spec, replaced sensor and verified operations heating to 350 with no issues.
Near San Marcos, Texas 78666
Derek S.
Job Details: 09/27/2018
WFG505M0BS3 Arrived on site to repair unit for f3 error, I found that the sensor was out of spec, replaced sensor and verified operations heating to 350 with no issues.
Near Leander, Texas 78641
Tyler B.
Job Details: 09/27/2018
Near Round Rock, Texas 78664
Wesley
Job Details: 09/27/2018
Arrived on site and found unit non serviceable brand. Advised customer that AHS would be notified.
Near Round Rock, Texas 78664
Wesley
Job Details: 09/27/2018
Arrived on site and found LF burner not igniting. Found visual evidence of extensive wear and tear and grease spillage. Unit will need ignition harness. To access ignition harness unit will also need all orifice holders and screws and double labor. Due to no model serial no parts ordered at time of service.
Near Bastrop, Texas 78602
Thomas L.
Job Details: 09/27/2018
Temps were 34 in fresh food section and 48 in freezer. It appears that the 3way valve is. It letting refrigerant flow to the freezer section. Ordering valve.
Near Killeen, Texas 76549
Arthur B.
Job Details: 09/27/2018
TFX26ZPDAWW (SxS Refrigerator) - Arrived onsite for customer complaint of SxS refrigerator missing screw in FC section and door not aligned. Found FC door is not aligned. Was able to adjust door to line up with RC door. Did find also, ice bin bracket on LH side is missing causing bucket to lean. LH bracket is no longer available. Advised that bracket is not causing any mechanical failure and bucket is still sitting to catch ice. No other issues found. All water connections were dry at time of service.
Near Kyle, Texas 78640
Derek S.
Job Details: 09/27/2018
MVWX655DW1 Arrived on site to check unit for not spinning out and clothes coming out wet, I found error basket speed fault, i recalibrated the unit, checked wiring and capacitor. I got 4 large towels completely soaking wet and ran a spin cycle, the towels came out dry and I verified the unit is working as designed. Instructed Mrs. that some cycles on loading and some loads may require and additional spin cycle, no water leak present at the time of service
Near Kyle, Texas 78640
Derek S.
Job Details: 09/27/2018
MVWX655DW1 Arrived on site to check unit for not spinning out and clothes coming out wet, I found error basket speed fault, i recalibrated the unit, checked wiring and capacitor. I got 4 large towels completely soaking wet and ran a spin cycle, the towels came out dry and I verified the unit is working as designed. Instructed Mrs. that some cycles on loading and some loads may require and additional spin cycle, no water leak present at the time of service
Near Leander, Texas 78641
Lou
Job Details: 09/26/2018
arrived on site to inspect dryer not heating. Upon further inspection, I verified ohms to the fuse and element. I checked ohms to the element cutoffs and found them to be open. When I pulled the element to inspect it, I found that the housing was burnt and about to crack which would cause it to not function; therefore, I removed and replaced the element and both element cutoffs ad tested and the unit operated as designed. No lint observed during service, job completed.
Near New Braunfels, Texas 78132
Derek S.
Job Details: 09/26/2018
WRF736SDAM13 Arrived on site and replaced the control due to unit not defrosting, also replaced the fan and grommet due to damage from ice and the bi metal due to damage from ice, leveled unit and verified operation, no water leak present at the time of service
Near New Braunfels, Texas 78132
Derek S.
Job Details: 09/26/2018
WRF736SDAM13 Arrived on site and replaced the control due to unit not defrosting, also replaced the fan and grommet due to damage from ice and the bi metal due to damage from ice, leveled unit and verified operation, no water leak present at the time of service