Near Manor, Texas 78653
Nathaniel B.
Job Details: 06/15/2018
WDF320PADB3, Unit has a 1 year extended warranty through the builder, Arrived on call for not draining water at end of the cycle, found can hear drain pump trying to run but not draining, found drain pump failed, replaced drain pump and know unit is draining water, all checks good, call complete, no water leaks at time of call
Near Manor, Texas 78653
Nathaniel B.
Job Details: 06/15/2018
WDF320PADB3, Unit has a 1 year extended warranty through the builder, Arrived on call for not draining water at end of the cycle, found can hear drain pump trying to run but not draining, found drain pump failed, replaced drain pump and know unit is draining water, all checks good, call complete, no water leaks at time of call
Near Lampasas, Texas 76550
Arthur B.
Job Details: 06/15/2018
RF378LXKT0 (Freestanding Range) - Arrived on-site fo customer complaint of freestanding range not heating past 350F. When arrived, unit was preheated to 350F. Raised temperature to 500F. Found control will not cycle allowing more heat to enter. Unit will need new control which is discontinued. AHS to contact customer. No other issues found.
Near Round Rock, Texas 78665
Jerry C.
Job Details: 06/15/2018
ED5PHEXNL00 Arrived to inspect noise. I found the custom had pulled the prior to my arrival to gain access to the electrical outlet. They described an issue where the unit would make a rattle/vibration noise about every two hours. The noise would persist for up to 30 minutes. I found the return line from the condenser to the cabinet was very close (1/8”) to the condenser and was very likely to be intermittently making contact. I corrected routing and tested. I verified the condenser fan operating correctly and noise free. I tested water dispensing and ice maker harvest and there were no noticeable noises. The evaporator was ice free. I feel the issue was vibration from the return line and has been corrected. No leaks observed during service.
Near Austin, Texas 78730
Luis
Job Details: 06/15/2018
Refrigerator-replaced main control and ui
Near Driftwood, Texas 78619
Robert
Job Details: 06/15/2018
KRMF606ESS01 Arrived on job to replace motor. After replacement of part test motor all good. No leaks detected at time of service
Near Austin, Texas 78738
Brandon
Job Details: 06/15/2018
Arrived on site for washer not finishing cycle on heavy loads. I put unit into diagnostic mode, unit tested good mechanically, however we did get some vibration during high spin. I calibrated the unit, and instructed customer to run a load. If problem continues, will need suspension rods.
Near Austin, Texas 78746
Kevin
Job Details: 06/15/2018
Arrived on site and found no saved error codes, ran a diagnostic cycle and found no failures and no new error codes generated after cycle. Techline Leon, SR7722235740 Did not make any specific recommendations for replacement of parts. Adjusted soap level from 2 to 6 per tech line recommendation, requested that customer continue to use washer and monitor it for any further concerns. No water leaks from connections at time of service, job complete. 6/12/18 17:46: KB invlvd 6/12 TUE, 17:46 to 17:46, Arrived on site and set unit into diagnostic cycle Only found a long drain error code. Found Bellow drains are clogged and cleared them, detergent reservoir may be allowing too much soap into washer and causing a sudsing issue. Washer passed diagnostic cycle without generating more error codes, SR7722213448; ordrng 1 W10250743A (D2C dispenser), schdld next appmnt for 6/14 THU !
Near Pflugerville, Texas 78660
Nathaniel B.
Job Details: 06/15/2018
Model JGBS65REF2SS, Arrived on call for only left rear burner not lighting, replaced left rear burner head and tested and all checks good left rear burner is know lighting as it should, all checks good, other parts ordered just incase needed are not needed, call complete, no gas leaks at time of call call complete.
Near Pflugerville, Texas 78660
Nathaniel B.
Job Details: 06/15/2018
Model JGBS65REF2SS, Arrived on call for only left rear burner not lighting, replaced left rear burner head and tested and all checks good left rear burner is know lighting as it should, all checks good, other parts ordered just incase needed are not needed, call complete, no gas leaks at time of call call complete.
Near Austin, Texas 78724
Joseph C.
Job Details: 06/15/2018
MGDB835DW4 Arrived on site for “lint light flashing and unit will not start” complaint. Inspected unit and found customer was not holding start button down long enough to start unit. Unit is performing as designed. No leaks detected, at time of service. Instructed customer to clean venting every six months to prevent possible fire hazards and for better performance and economy.
Near Austin, Texas 78703
Leonardo
Job Details: 06/15/2018
Whirlpool dishwasher not advancing model: WDF320PADS3. Arrived on site to replace board. Replaced board test unit and unit test good unit washing and draining correctly heater coming on. No leaks present at this time.
Near New Braunfels, Texas 78130
Connor M.
Job Details: 06/15/2018
KFIV29PCMS kitchenaid refrigerator Arrived on site to test unit for making strange noises and smell from ff section. Ran full diagnostic check found no issue. Made customer aware of oressure equalizations and 3 way valve noises. Unit no longer smells.
Near Pflugerville, Texas 78660
Nathaniel B.
Job Details: 06/15/2018
Model WDF320PADB1, Arrived on call for display panel not lighting and dispenser broken and no heat , 7-1 which is a no heat error, 5-1 which is door switch stuck open, 6-6 which is incoming water temp is below 84 degrees, checked heat cycle and is coming on it is drawing 8.5 amps on black wire at front of dishwasher when forced on on the heat cycle which is good, customer had found prior to service that the heating element wire was disconnecter under dishwasher so they reconnected it but says still has not drying issue and poor clean, found that customer has not been running hot water at sink before starting dishwasher and is using to much soap and rinse aid, instructed customer on soap start with table spoon of liquid and if sudsing reduce to tea spoon of liquid soap and rinse aid found it was set at max and being customer is not on a water softner set the rinse aid to 2 on dispenser, also found dispenser door is broken, will need to replace dispenser, dispenser , also found that a
Near Pflugerville, Texas 78660
Nathaniel B.
Job Details: 06/15/2018
Model WDF320PADB1, Arrived on call for display panel not lighting and dispenser broken and no heat , 7-1 which is a no heat error, 5-1 which is door switch stuck open, 6-6 which is incoming water temp is below 84 degrees, checked heat cycle and is coming on it is drawing 8.5 amps on black wire at front of dishwasher when forced on on the heat cycle which is good, customer had found prior to service that the heating element wire was disconnecter under dishwasher so they reconnected it but says still has not drying issue and poor clean, found that customer has not been running hot water at sink before starting dishwasher and is using to much soap and rinse aid, instructed customer on soap start with table spoon of liquid and if sudsing reduce to tea spoon of liquid soap and rinse aid found it was set at max and being customer is not on a water softner set the rinse aid to 2 on dispenser, also found dispenser door is broken, will need to replace dispenser, dispenser , also found that a
Near Austin, Texas 78724
Joseph C.
Job Details: 06/15/2018
MFC2062FEZ01 Arrived on site for “no water flow and low ice production” complaint. Inspected unit and found inlet line bent. Straightened line. Tested unit. Unit is performing as designed. No leaks detected, at time of service.
Near Georgetown, Texas 78628
Dona
Job Details: 06/15/2018
Arrived on site for frost build up in freezer section, found right hand side of rollers off track not allowing for even closure of freezer door, put roller back on track even with left side. Verified unit is closing correctly. Unit is not hooked to water. Also found filter housing off of frame. Reseated housing. Unit checks ok.
Near Blanco, Texas 78606
Robert
Job Details: 06/15/2018
JES9860CAB01 Arrived on job to replace relay. After replacement of relay test burners all working.
Near Georgetown, Texas 78633
Dona
Job Details: 06/15/2018
Arrived on site for higher temps in freezer upper compartment but fridge temps ok. Upon arrival freezer temps at 2 degrees, fridge at 38 degrees. Customer stated that they had put extra groceries in freezer and blocked off evaporator area. Once they removed groceries temperatures went back to normal. Advised customer not to block off area. Checked thermistors all checked good. No errors, opens, or shorts. All parms check good. All water connections dry. Rf100 Collected 108.24 on card.
Near Austin, Texas 78748
Kevin
Job Details: 06/15/2018
Arrived on site and replaced start switch diagnosed by previous technicians, after replacement dryer will now begin a psycho normally. No further repair is required at this time, job complete.
Near Austin, Texas 78745
Leonardo
Job Details: 06/15/2018
Whirlpool dishwasher no power model: WDF330PAHS0. Arrive don site to test unit for no power. Test unit and found outlet had 120v. Removed junction cover and found loose white wire. Secured white wire test unit and unit test good job complete no leaks present.
Near Round Rock, Texas 78664
Lou
Job Details: 06/14/2018
arrived on site to install previously diagnosed and ordered parts. Removed and replaced the upper rack adjusters and lower rack wheels. Tested unit and unit operates as designed. No water leaks observed during service. Job completed.
Near Cedar Park, Texas 78613
Lou
Job Details: 06/14/2018
arrived on site to inspect dryer taking a long time to start. Upon arrival, I meet with the customer and she demonstrated what the issue was that she is having with the unit. She advised that she places her clothes in the unit and pushes the power button then pushes the start button. I questioned the customer on how she attempts to start the unit and she again demonstrate that she pushes the start button (quick tap on start button). I advised the customer that when pushing the start button, she would need to hold the start button for approximately three seconds and the unit would start and I demonstrated for her the difference in tapping the start and holding my finger on it for three seconds. I placed the unit in diagnostics and checked for error codes and there were none. I verified all connections and verified ohms at the fuse, cutoff and element and I verified that the unit was heating properly (212 degrees). No lint observed during service.
Near Hutto, Texas 78634
Nathaniel B.
Job Details: 06/14/2018
Model GI6FDRXXY010, Arrived on call for ice maker not calling for water and also freezer drain i ed over, installed parts previously ordered and freezer is know draining properly and ice maker cycled and filled with water and no leaks after repair, call complete.
Near Hutto, Texas 78634
Nathaniel B.
Job Details: 06/14/2018
Model GI6FDRXXY010, Arrived on call for ice maker not calling for water and also freezer drain i ed over, installed parts previously ordered and freezer is know draining properly and ice maker cycled and filled with water and no leaks after repair, call complete.
Near Holland, Texas 76534
Arthur B.
Job Details: 06/14/2018
MFF2558VEM10 (French Door Refrigerator) - Arrived onsite to install drain tube to French door refrigerator from prior tech's diagnosis. Removed back unit cover. Installed new drain tube. Defrost water flows as intended. No other issues. All water connections were dry at time of service.
Near Smithville, Texas 78957
Carlos G.
Job Details: 06/14/2018
29, Arrived onsite for customer compliant of getting very little water issue. Checked components and found a a faulty valve
Near Bee Cave, Texas 78738
Luis
Job Details: 06/14/2018
Refrigerator-replaced water filter head
Near Austin, Texas 78759
Scott
Job Details: 06/14/2018
Arrived on site for noisy diffuser . Ran diagnostics test , evap fan is running normal . Diffuser making a ratcheting sound when opening and closing . No ice or frost build up in or around diffuser . Replaced diffuser and all sounds normal . No water leaks detected at time of service .
Near Buda, Texas 78610
Robert
Job Details: 06/14/2018
WED4800BQ1 Arrived on job for complaints of dryer not running. Test dryer and shutting off after about 3 minuets. Will restart then shutting off faster. Timer sent wrong
Near Rogers, Texas 76569
Arthur B.
Job Details: 06/14/2018
WRF767SDEM01 (Dual Evaporator French Door Refrigerator) - Arrived onsite to install parts to dual evaporator French door refrigerator. When arrived,customer had unit fully defrosted and cleaned out. Removed RC evaporator cover, thermistor and damper. Installed new replacements. Verified thermistor is placed in proper location. Reassembled. Powered unit on. Good frost pattern began forming. Advised customer to wait 24 hrs before placing items back in unit. All water connections were dry at time of service.
Near Rogers, Texas 76569
Arthur B.
Job Details: 06/14/2018
Near Temple, Texas 76502
Dona
Job Details: 06/14/2018
Arrived on site for no agitation, found wash plate is not worn down smooth and is not grasping on to gearcase any longer. Gearcase seems to be ok. Will bring on return visit in case wash plate has worn down grooves of gearcase. If washplate has worn down will need gearcase and new cam. Will need CNOTE authorization. All water connections dry. Sarah assisted with reschedule and parts.
Near Austin, Texas 78735
Luis
Job Details: 06/14/2018
Refrigerator-replaced damper control
Near Liberty Hill, Texas 78642
Thomas L.
Job Details: 06/14/2018
Arrived on site for F6E2 failure code. Removed and replaced failed user interface. Unit now operates properly with no water leaks.
Near Austin, Texas 78617
Robert
Job Details: 06/14/2018
WFC150M0EW0 Arrived on job for complaints of burners not working. Found the right rear left rear and front left burner switches not working as well as burners damaged. Replaced all switches and burners and test.
Near Killeen, Texas 76543
Arthur B.
Job Details: 06/14/2018
GD5RHAXNT00 (SxS Refrigerator) - Arrived onsite to install parts to SxS refrigerator from prior tech's diagnosis. Was able to seal RF liner and cabinet using clear silicone. Upon removing dispenser motor, found part was incorrect. Will need to order new dispenser motor to complete repair. R/S for 6/19 per CS. All water connections were dry at time of service.
Near Belton, Texas 76513
Dona
Job Details: 06/14/2018
Arrived on site for unit stopping at different parts in cycle. Found customer is using sensor dry. Unit is adjusting per wetness. Found unit is running to spec. Explained estimated times to customer and difference from timed dry to sensor dry. Verified sensors are working correctly.
Near Belton, Texas 76513
Dona
Job Details: 06/14/2018
Arrived on site for unit not spinning out at last spin, found unit was set at no spin cycle. Showed customer cycle selections, adjusted cycle to have a spin. Ran unit through quick cycle with clothing, found unit running to spec. All water connections dry.
Near New Braunfels, Texas 78132
Diego G.
Job Details: 06/14/2018
Arrived on site. Check for no heat issues. Ran diagnostic test found no error codes. Found no rinse aid in reservoir. Instructed customer on using rinse aid to improve drying cycles. No leaks present. Job complete
Near New Braunfels, Texas 78132
Diego G.
Job Details: 06/14/2018
Arrived on site. Check for no heat issues. Ran diagnostic test found no error codes. Found no rinse aid in reservoir. Instructed customer on using rinse aid to improve drying cycles. No leaks present. Job complete
Near New Braunfels, Texas 78132
Diego G.
Job Details: 06/14/2018
Arrived on site. Check for no heat issues. Ran diagnostic test found no error codes. Found no rinse aid in reservoir. Instructed customer on using rinse aid to improve drying cycles. No leaks present. Job complete
Near Bastrop, Texas 78602
Carlos G.
Job Details: 06/14/2018
Arrived onsite for customer compliant of damages. Confirmed damages. Office to order parts for return visit and reschedule customer. ; ordrng 1 W10611544 (panel-re
Near Leander, Texas 78641
Lou
Job Details: 06/14/2018
arrived on site to inspect oven elements not working. Upon further inspection, I verified ohms at the bake element but the broil element was showing open. Tested unit and broil element did not heat up. I verified ohms at the TOD, as well. Office to order broil element and scheduled return service for 06/18/18 EB.
Near Austin, Texas 78746
Scott
Job Details: 06/14/2018
Arrived on site for slow drying . Ran air vent test , failed both with and with out duct on. Checked all thermostats and heater , all checked normal . Took blower wheel housing off and found it jam packed with lint . Cleaned lint out of housing . Ran air test again , passed with duct on . No lint build up inside of unit at time of service . Job complete . Wp elect dryer
Near Burnet, Texas 78611
Thomas L.
Job Details: 06/14/2018
Arrived on site for drum not rotating. Found drum binding on front seal. Corrected seal issue and tested. Dryer is clean of lint.
Near Austin, Texas 78724
Joseph C.
Job Details: 06/14/2018
KMHS120ESS4 I’ve done on site for “open/close door error” inspected unit and found lower interlock mechanism not engaged with door tab. Adjusted lower interlock. Tested unit. Unit is performing as designed.
Near Leander, Texas 78641
Lou
Job Details: 06/14/2018
arrived on site to inspect dishwasher leaking. Upon further inspection, I placed the unit in diagnostics and tested. As soon as the unit filled and began to wash, the unit began leak at or near the diverter. I immediately shut the unit off and quoted the customer for repairs..$210.98 for sump/motor assembly, DW625 $179.99 and total with tax was $423.23. Customer advised that he would purchase a new unit and paid the diagnostics fee of DW100 $108.24. I ran the drain pump again to drain any excess water from the unit. Instructed customer of detergent use and care for the unit. No water leaks at the end of service.
Near Austin, Texas 78748
Robert
Job Details: 06/14/2018
WTW4816FW2 Arrived on job for complaints of no cold water. Found cold water valve not closing allowing water to come in wail off. Replaced valve and test operation normal. No additional leaks detected. Job complete
Near Austin, Texas 78703
Connor M.
Job Details: 06/14/2018
KUIC18PNTS1 kitchenaid ice machine Arrived on site to test unit for not making ice. Found in step diagnostic that compressor would not power on. Pulled unit to check compressor electricals and found compressor has been being leaked on for several years causing a hole to form in The compressor. Customer decided to replace unit before i generated a quote. Collected second appliance swrvice charge. No leaks detected.
Near Austin, Texas 78703
Connor M.
Job Details: 06/14/2018
KUDE201XSS8 kitchenaid dishwasher Arrived on site to test unit for water remaining in tub after wash intermitently. Found error for stuck check valve. Customer has never ran a clean cycle. Visually inspected check valve and fiund no failure. Instruct on running clean dishwasher cycle and also corrected drain loop issue. Unit working properly, no leaks detected. Collected for service not listed minor
Near Copperas Cove, Texas 76522
Arthur B.
Job Details: 06/14/2018
ED5PBAXVY00 (SxS Refrigerator) - Arrive onsite to conduct sealed system repair on SxS refrigerator from prior tech's diagnosis. Removed compressor and drier. Installed new compressor, UV drier using braising method. Vacuumed system down to -25psi. Charged unit with 5.0oz of R134a refrigerant. Powered unit up. Found good first pattern on evaporator. No other issues found at this time. No water connections made to unit.
Near Austin, Texas 78733
Paul
Job Details: 06/14/2018
Maytag Washer Model MHW7000XW0. Arrived onsite for the washer with a broken door handle that needs the door replaced that the customer already has. I found the outer door broken. I removed the door and replaced the outer door. I reinstalled the door and made sure the door opened and closed properly. Call complete.
Near Copperas Cove, Texas 76522
Arthur B.
Job Details: 06/14/2018
RF265LXTY3 (Freestanding Range) - Arrived onsite to install parts to free standing range from prior tech's diagnosis. Removed cooktop to replace RF Element. Removed back cover and removed and replaced LF infinite switch. Found also RF Infinite burnt as well. Will need to order WP3149400. R/S date for 6/18 per SP. Reassembled. No other issue found.
Near Georgetown, Texas 78633
Dona
Job Details: 06/14/2018
Arrived on site for high temps in ff section. Found evap cover caked with ice. Will need to replace evap cover with fan. Customer will defrost unit before return. Also found freezer is built up heavily with ice, will need new door seal for freezer. User interface will not go into diagnostics and is not accepting all commands. Will need to replace UI as well. Will seal around freezer door and ff section upon return with silicone. All water connections dry. Sarah assisted with reschedule and parts.
Near Austin, Texas 78721
Joseph C.
Job Details: 06/14/2018
NTW4516FW2 Arrived on site for “not completing cycle” complaint. Inspected unit and found door latch faulty. Ordering new. Return for repairs on 06/18. No leaks detected, at time of service.
Near Leander, Texas 78641
Lou
Job Details: 06/14/2018
arrived on site to inspect refrigerator making loud noise and frost buildup in fc. Upon further inspection, I found that when the unit kicks on the condenser vibrates badly making a loud noise. Also, I found that the fc door would not close on its own and there was a small amount of frost buildup on the food inside the fc. I checked the gasket for any gaps and the gasket was sealing properly. The fc light did not come on, but once I pushed the switch in and released it, the light came on. I verified the ice pattern on the evaporator and there was no ice buildup on the Evap. I moved the unit out of its space and then placed it back and leveled the unit. I then placed a piece of foam in between the condenser and the chassis and the loud noise stopped. After leveling the unit, the fc door closed on its own like it's supposed to. I found small gapping between the chassis and the fc chamber on both sides and sealed it using manufacturers approved silicone. Advised the customer that the unit
Near Waco, Texas 76708
Mike G.
Job Details: 06/14/2018
ASI2575FRS00, Arrived on site for unit making a noise checked unit and found that the condenser is vibrating on bracket Reposition condenser and is no longer vibrating and unit is no longer making noise checked unit for water leaks and no leaks found at time checked of srv..l unit checked fine at this time....
Near Waco, Texas 76708
Mike G.
Job Details: 06/14/2018
ASI2575FRS00, Arrived on site for unit making a noise checked unit and found that the condenser is vibrating on bracket Reposition condenser and is no longer vibrating and unit is no longer making noise checked unit for water leaks and no leaks found at time checked of srv..l unit checked fine at this time....
Near Granite Shoals, Texas 78654
Thomas L.
Job Details: 06/14/2018
Arrived on site for poor washability. Found that motor failed and would not run. Replaced and tested and all water connections were dry.
Near Elgin, Texas 78621
Nathaniel B.
Job Details: 06/14/2018
Model WRT518SZFM00, Arrived on call for icemaker not making any ice and and water is dripping in to the ice bin and freezing the ice bin cubes in clumps, found that ice maker is making ice but when fills with water it runs in to the ice bin is the complaint, found that sleeve that is over the fill tube was not inserted in to the fill cup properly, inserted sleeve in to fill cup and tested and no leaks, all checks good, call complete.
Near Elgin, Texas 78621
Nathaniel B.
Job Details: 06/14/2018
Model WRT518SZFM00, Arrived on call for icemaker not making any ice and and water is dripping in to the ice bin and freezing the ice bin cubes in clumps, found that ice maker is making ice but when fills with water it runs in to the ice bin is the complaint, found that sleeve that is over the fill tube was not inserted in to the fill cup properly, inserted sleeve in to fill cup and tested and no leaks, all checks good, call complete.
Near Leander, Texas 78641
Steve C.
Job Details: 06/14/2018
Near Manor, Texas 78653
Wesley
Job Details: 06/14/2018
Clogged washer drain.
Near Austin, Texas 78703
Connor M.
Job Details: 06/14/2018
WDT780SAEM2 whirlpool dishwasher Arrived on site to install parts for repair. Installed float housing, float and gasket. Unit working properly, no leaks detected.
Near Austin, Texas 78723
Joseph C.
Job Details: 06/14/2018
WDF560SAFM2 Arrived on site for “unit not cleaning dishes completely” complaint. Inspected unit and found inlet valve loaded with grit from water lines. Removed and replaced inlet valve. Tested unit. Unit is performing as designed. No leaks detected, at time of service.
Near Austin, Texas 78704
Robert
Job Details: 06/14/2018
KUIX305ESS2 Arrived on job for complaints of too much ice. Thermistor for bin not in range. Replaced thermistors run test for all thermistors and change ice thickness to max.
Near Georgetown, Texas 78633
Dona
Job Details: 06/14/2018
Arrived on site for high temps in ff section. Found evap cover caked with ice. Will need to replace evap cover with fan. Customer will defrost unit before return. Also found freezer is built up heavily with ice, will need new door seal for freezer. User interface will not go into diagnostics and is not accepting all commands. Will need to replace UI as well. Will seal around freezer door and ff section upon return with silicone. All water connections dry. Sarah assisted with reschedule and parts.
Near Lago Vista, Texas 78645
Jerry C.
Job Details: 06/14/2018
MET8720DS01 Arrived to inspect burnt cooktop. I found the front right element appeared to have experienced an over-temperature issue. I removed and replaced the element due to thermal limiting being controlled at that point and replaced the cooktop. Operational test good.
Near Woodway, Texas 76712
Mike G.
Job Details: 06/14/2018
KDTM354DSS4, Arrived on site for door will not shut checked unit and found the dooe strike is damaged and will let the door to shut and start the unit replaced door strike and checked unit after repair and found that the door is now shutting properly and unit is now starting checked unit for water leaks and no leaks found at time of srv... unit checked fine at this time....
Near Woodway, Texas 76712
Mike G.
Job Details: 06/14/2018
KDTM354DSS4, Arrived on site for door will not shut checked unit and found the dooe strike is damaged and will let the door to shut and start the unit replaced door strike and checked unit after repair and found that the door is now shutting properly and unit is now starting checked unit for water leaks and no leaks found at time of srv... unit checked fine at this time....
Near Manchaca, Texas 78652
Luis
Job Details: 06/14/2018
Refrigerator-replaced water filter housing
Near Manor, Texas 78653
Wesley
Job Details: 06/14/2018
Repairing freezer door alignment for better seal.
Near Granite Shoals, Texas 78654
Thomas L.
Job Details: 06/14/2018
Arrived on site for no ice and standing water in unit. Found failed drain pump. Replaced and tested. All water connections were dry. Entered cabana via key in flower bed which I returned after repairs were completed.
Near Austin, Texas 78703
Connor M.
Job Details: 06/14/2018
WDT780SAEM1 whirlpool dishwasher Arrived on site to test unit for dishes not drying. Ran diagnostic cycle and confirmed heater is operating. Found rinse aid dispenser empty. Instruct customer on proper use and care. No leaks detected.
Near San Marcos, Texas 78666
Carlos G.
Job Details: 06/14/2018
Arrived onsite for customer compliant of door and exhaust issues. Found exhaust behind unit crushed (builder to replace. Also adjusted catch on door. All checks ok now. Job complete.
Near Austin, Texas 78746
Scott
Job Details: 06/14/2018
Arrived on site for heater catching fire . Ran diagnostics got low water and sensor error codes . Checked heater all checked good , some minor white discoloration due to soap build up .heater ohm out normal and no burn marks on element . Ran test cycle and got sensor error at end of cycle , all else checked normal .Did find sensor shorted out , more then likely causing heater to run hotter and longer then normal . Ordering sensor and will bring back control only if needed . Return 6/18 . No water leaks detected at time of service .
Near Leander, Texas 78641
Steve C.
Job Details: 06/14/2018
Near Hewitt, Texas 76643
Mike G.
Job Details: 06/14/2018
WFE540H0AS0, Arrived on site for unit not heating properly, checked unit and found that the bake element is shorted out replaced bake element and checked unit and unit is now heating properly unit checked fine at this time....
Near Hewitt, Texas 76643
Mike G.
Job Details: 06/14/2018
WFE540H0AS0, Arrived on site for unit not heating properly, checked unit and found that the bake element is shorted out replaced bake element and checked unit and unit is now heating properly unit checked fine at this time....
Near Austin, Texas 78701
Luis
Job Details: 06/14/2018
Refrigerator-repaired water lines and ice dispenser door
Near Austin, Texas 78744
Connor M.
Job Details: 06/14/2018
NTW4516FW2 Amana washer Arrived on site to install control for failure. Installed and tested unit. Unit working properly, no leaks detected.
Near Georgetown, Texas 78633
Dona
Job Details: 06/14/2018
Arrived to find right door sitting lower than left door. Found door adjuster is maxed out. Found door cams worn down, replaced door cams. Verified door sealing properly. Doors are level. All water connections dry. Unit checks good.
Near Seguin, Texas 78155
Leonardo
Job Details: 06/14/2018
Maytag dishwasher door not closing model: MDB8959SFH0. Arrived on site to test unit for door not closing. Found right side track not going all the way back making upper rack not go all the way back. Making door hit rack making door not close. Replace dleft and right track test unit and unit test good door closing all the way no leaks present job complete
Near San Marcos, Texas 78666
Carlos G.
Job Details: 06/14/2018
Arrived onsite for customer compliant of noise issues. Ran test cycle and found screw in between basket. Corrected issue.
Near Marble Falls, Texas 78654
Thomas L.
Job Details: 06/14/2018
Arrived on site or dryer not drying properly. Tested unit and found unit was heating but not venting. Further diagnosis found blower wheel loose on motor shaft. Correct the blower wheel and re-tested. Unit is operating properly. Dryer vent is clean and new.
Near Austin, Texas 78748
Connor M.
Job Details: 06/14/2018
AER5630BAB0 Amana range Arrived on site to install harnesses for repair. Found other harnesses for burners needed. Parts research. Office to schedule directly.
Near Hewitt, Texas 76643
Mike G.
Job Details: 06/14/2018
KOSC504ESS00, Arrived on site for unit will not power on checked unit and found that inline fuse and TOD are bad replaced part and checked unit after repair and unit is now powering on and unit is heating unit checked fine at this time....
Near Hewitt, Texas 76643
Mike G.
Job Details: 06/14/2018
KOSC504ESS00, Arrived on site for unit will not power on checked unit and found that inline fuse and TOD are bad replaced part and checked unit after repair and unit is now powering on and unit is heating unit checked fine at this time....
Near Pflugerville, Texas 78660
Nathaniel B.
Job Details: 06/14/2018
Model WRX988SIBM03, Arrived on call for still leaking water from dispenser area, installed parts that previous tech ordered but one of the clips not needed because there is only one clip and the previous tech ordered 2, checked operation of water and calling for ice and all checks good, no water leaks after repair. Call complete.
Near Pflugerville, Texas 78660
Nathaniel B.
Job Details: 06/14/2018
Model WRX988SIBM03, Arrived on call for still leaking water from dispenser area, installed parts that previous tech ordered but one of the clips not needed because there is only one clip and the previous tech ordered 2, checked operation of water and calling for ice and all checks good, no water leaks after repair. Call complete.
Near Killeen, Texas 76549
Arthur B.
Job Details: 06/14/2018
KRMF706ESS01 (5 Door French Door Refrigerator) - Arrive onsite to install new freezer drawer to French door refrigerator from prior tech's diagnosis. Removed broken drawer and installed new replacement. Drawer slides open and closes and intended. No other issues found. All water connects were dry at time of service.
Near Rollingwood, Texas 78746
Scott
Job Details: 06/14/2018
Kitchenaid microwave w/trim kit . Turntable motor
Near Georgetown, Texas 78633
Dona
Job Details: 06/14/2018
Arrived on site for unlevel grates. Found back right grate unlevel rocking a level. Replaced with new grate kit. Applied level throughout grate surface and found no rocking. Unit is working to spec and grates are level.
Near Killeen, Texas 76549
Arthur B.
Job Details: 06/14/2018
MVWC415EW2 (Top Load Washer) - Arrived onsite for customer complaint of top load washer dispenser broke off and won't stay on. Confirmed issue. Installed new barrel and dispenser. Calibrated unit. Unit calibrated successfully. No other issues found at this time. All water connections were dry at time of service.
Near Austin, Texas 78746
Luis
Job Details: 06/14/2018
Refrigerator-replaced failed thermostat
Near Georgetown, Texas 78626
Dona
Job Details: 06/14/2018
Arrived on site for no wash condition, found motor seized. Found drain solenoid is not engaging. Will have to replace wash impeller and tub connector due to removing from tub. solenoid-48.80 Impeller kit-67.75 Connector for pump-34.42 Pump and motor-249.71 Labor-dw-120 224.99. Total 677.29 Customer is not wanting to complete the repair today. Will call office if decides to repair. All water connections dry, SW collected service fee of 108.24.
Near Georgetown, Texas 78626
Dona
Job Details: 06/14/2018
Arrived on site to install deli control and user interface. Previous tech found deli control shorted not allowing for ice production or water flow due to affecting valve performance. Previous tech also found that the user interface was not allowing for all selections. Replaced both UI and deli control, verified water valve working on door for water flow. All water connections dry. All parms check good.
Near Marble Falls, Texas 78654
Thomas L.
Job Details: 06/14/2018
Arrived on site for no ice dispensing. Found shaft coupling cracked. Replaced shaft and operations are now normal. All water connections are dry.
Near Pflugerville, Texas 78660
Nathaniel B.
Job Details: 06/14/2018
Model KUDS35FXSSA, Arrived on call for grinding noise from pump motor assem., replaced pump motor assem. That previous tech ordered and tested and noise is gone, no water leaks after repair, call complete.