Near Leander, TX 78641
Lou
Job Details: 04/24/2018
arrived on site to install previously diagnosed and ordered parts. Removed and replaced the outer door glass and door gasket. Installed an installation strip as advised in a service pointer. Tested unit and unit tested good. Advised customer of my work. No gas leaks detected during service.
Near Waco, TX 76710
Mike G.
Job Details: 04/24/2018
MGR8700DS3, Arrived on site for broiler not working checked unit and found that the broiler ignitor is not Sparking replaced broiler ignitor checked unit and found that the broiler is now now lighting checked unit for gas leaks and no leaks found at time of srv... unit checked fine at this time....
Near Waco, TX 76710
Mike G.
Job Details: 04/24/2018
MGR8700DS3, Arrived on site for broiler not working checked unit and found that the broiler ignitor is not Sparking replaced broiler ignitor checked unit and found that the broiler is now now lighting checked unit for gas leaks and no leaks found at time of srv... unit checked fine at this time....
Near Georgetown, TX 78633
Mike C.
Job Details: 04/24/2018
Whirlpool microwave WMH32517AS1 Arrived to check unit for not heating. Found 122 volts at high voltage transformer input side. Found capacitor and diode have shorted out the magnetron. Installed new capacitor, diode and magnetron, checked operation and unit checks good. MW140 $159.99 - Magnetron $149.97 - Capacitor $67.65 - Diode $45.64
Near Belton, TX 76513
Dona
Job Details: 04/24/2018
Arrived on site for knocking noise, found hot and cold water hoses swapped on back of unit, when valve turning on and off hoses hitting back of machine. All parms checked good, all water connections dry. Customer will swap hot and cold. Customer needed to pick up kids. No abnormal noises no errors. All operations normal.
Near Horseshoe Bay, TX 78657
Thomas L.
Job Details: 04/24/2018
Arrived on site for inspection of unit that caught on fire. Found that the entire control panel area was charred from fire that happened in left side of the control board. Control panel 4451063 is discontinued. Main control board 4448869 is discontinued. The entire wire harness for both units would have to be replaced. Due to heat it appears that the wave guide got damaged and that is not a replaceable part. My opinion is that this unit is not repairable and I would be afraid that every electrical component in both unit would have to also be replaced as it is still not for certain which part caused fire. This unit also caught house cabinet on fire as well. The customer has expressed that they could never trust this unit again.
Near Waco, TX 76710
Mike G.
Job Details: 04/24/2018
WDTA50SAHW0, Arrived on site to install new OWI sensor checked unit after repair and unit washing and element is heating checked unit for water leaks and no leaks found at time of srv...l unit checked fine at this time....
Near Waco, TX 76710
Mike G.
Job Details: 04/24/2018
WDTA50SAHW0, Arrived on site to install new OWI sensor checked unit after repair and unit washing and element is heating checked unit for water leaks and no leaks found at time of srv...l unit checked fine at this time....
Near Morgan's Point Resort, TX 76513
Dona
Job Details: 04/24/2018
Arrived on site for fridge drawer not shutting because of ice build up, defrosted full evap, replaced evap cover with new screws on top, installed wire harness. Verified temps unit checked ok, customer to monitor, all water connections dry.
Near Volente, TX 78641
Lou
Job Details: 04/24/2018
arrived on site to inspect refrigerator not cooling. Upon inspection, I found that the evaporator cover had ice buildup on it. I was able to get the Evap cover off to inspect the Evap coil and found a large amount of ice buildup on the coil. I advised the customer that they would need to defrost the unit before I could go any further with service. I had the customer sign a waiver and advised the customer to put several towels down around the unit due to water spillage. Also advised the customer to use a wet/vac to vacuum up as much water as they could to protect their floors. Office to order Evap cover and return service is scheduled for 04/26/18 CS. I will return with RC Thermistor. No water leaks observed during service.
Near Austin, TX 78737
Luis
Job Details: 04/24/2018
Refrigerator-installed water line to unit
Near Austin, TX 78737
Brandon
Job Details: 04/24/2018
Arrived on site for dishwasher not cleaning dishes, found power getting to wash motor, found bad wash motor. I replaced sump, unit tested good, water lines were dry at time of service.
Near Marble Falls, TX 78654
Thomas L.
Job Details: 04/24/2018
Removed and replaced fresh food section door due to surface rust with permission of factory. All water connections were dry.
Near Pflugerville, TX 78660
Nathaniel B.
Job Details: 04/24/2018
Model WRT111SFDW03, Arrived on call for buzzing noise from unit, found ive buildup only around fan motor, tested defrost and is good and cleared ive from evap fan and has good speed and no noise, sealed were inside liner meets outer cabinet on both sections due to air infultration to the fresh food and freezer causing ive around the evap fan motor, no parts needed, call complete, unit is not connected to water.
Near Pflugerville, TX 78660
Nathaniel B.
Job Details: 04/24/2018
Model WRT111SFDW03, Arrived on call for buzzing noise from unit, found ive buildup only around fan motor, tested defrost and is good and cleared ive from evap fan and has good speed and no noise, sealed were inside liner meets outer cabinet on both sections due to air infultration to the fresh food and freezer causing ive around the evap fan motor, no parts needed, call complete, unit is not connected to water.
Near Austin, TX 78705
Connor M.
Job Details: 04/24/2018
KUDC10FXSS4 kitchenaid dishwasher Control-198.42 wire harness-115.30 arrived on site to test unit for smoke and arching coming from control panel. Found control caught on fire and melted harnes where power goes into control. Will need harness and control to repair unit. Sw approved 5/1
Near Austin, TX 78705
Connor M.
Job Details: 04/24/2018
KSGG700ESS0 kitchenaid range Cooling fan-105.61 labor-169.99 arrived on site to test unit for not baking giving error code of cooling fan too slow. Diagnosed bad cooling fan. Replaced cooling fan and checked all function. Unit working properly at time of service.
Near Spicewood, TX 78669
Brandon
Job Details: 04/24/2018
Arrived on site for unit not draining, found bad drain pump, also cleaned out drain line, unit tested good.
Near Cedar Park, TX 78613
Lou
Job Details: 04/24/2018
arrived on site to inspect oven not heating. Customer advised that she turned the unit on preheat at 350 degrees and when she came back to put food in, the unit was still at 100 degrees. I placed unit in bake mode at 350 degrees and checked the Ignitor. The Ignitor never engaged. I checked ohms at the Ignitor and it was open. I installed an Ignitor and tested the unit and the unit operated as designed. No gas leaks detected during service.
Near The Hills, TX 78738
Luis
Job Details: 04/24/2018
Refrigerator-installed update fresh food evaporator,compressor and filter drier
Near Austin, TX 78753
Joseph C.
Job Details: 04/24/2018
WDF330PAHS1 I’ve done site for “wash cycle not working” complaint. Inspected unit and found water supply valve shut off. Cut water on and tested unit. Unit is performing as designed. No leaks detected, at time of service.
Near Kyle, TX 78640
Robert
Job Details: 04/24/2018
WFG505M0BS2 Whirlpool has range
Near Pflugerville, TX 78660
Nathaniel B.
Job Details: 04/24/2018
Model AMV1150VAS5, Arrived on call for microwave not heating found unit drawing 4 watts when running, found cap, diode and mag are bad, replaced all 3 and tested and all checks good, unit is know heating, call complete.
Near Pflugerville, TX 78660
Nathaniel B.
Job Details: 04/24/2018
Model AMV1150VAS5, Arrived on call for microwave not heating found unit drawing 4 watts when running, found cap, diode and mag are bad, replaced all 3 and tested and all checks good, unit is know heating, call complete.
Near Belton, TX 76513
Dona
Job Details: 04/24/2018
Arrived on site for unit leaking profusely from door, found leveling legs were low. Raised legs. also found crack on left and right hand side of inner door, latch is broken off of UI side, will need latch kit, and UI and inner door. Water connections are dry. Has been leaking for a couple months, customer has still been running, took pictures of flooring. May need authorization. Leaking stopped once legs were leveled. Erika assisted with parts office will need to reschedule.
Near Belton, TX 76513
Dona
Job Details: 04/24/2018
Kesha file#7721815050, spoke with tech line. No errors heater ohms correctly, voltage good from control to element. Incoming water temperature 126degrees. Rinse aid has been turned up to 3. All operations are working correctly at this time. Discussed with techline that customer needs to run water prior to starting load, if delayed always purge water before running. Per customer dishes are clean but not all are dried. Did not feel as though it was hot enough inside and dishes did not feel hot. All water connections dry.
Near Cedar Park, TX 78613
Lou
Job Details: 04/24/2018
arrived on site for dishwasher with error code F2E2. Upon inspection, I attempted to place the unit into diagnostics, but the unit would not respond. I disconnected the UI from the main control and turned the power source on and the units drain pump activated. I reconnected the UI to the control and still had no operation. Office to order UI and schedule return service. I will return with the main control on next service date. No water leaks observed during service.
Near Dripping Springs, TX 78620
Brandon
Job Details: 04/24/2018
Near Cedar Park, TX 78613
Lou
Job Details: 04/24/2018
arrived on site for refrigerator/freezer not cooling. Upon further inspection, I found that the freezer coil had not frost pattern. I felt the compressor and it was cold to touch. I verified ohms to the compressor and verified ohms to the start device and found that the wiring was not correct. I corrected the wiring and tested unit and the unit tested good. Unit began to cool as designed. No water leaks observed during service.
Near Waco, TX 76705
Mike G.
Job Details: 04/24/2018
WDF520PADW7, Arrived on site to install new OWI sensor and motor and pump checked unit after repair and unit is now washing and heating checked unit for water leaks and no leaks found at time of srv... control is not needed unit checked fine at this time....
Near Waco, TX 76705
Mike G.
Job Details: 04/24/2018
WDF520PADW7, Arrived on site to install new OWI sensor and motor and pump checked unit after repair and unit is now washing and heating checked unit for water leaks and no leaks found at time of srv... control is not needed unit checked fine at this time....
Near Austin, TX 78701
Connor M.
Job Details: 04/24/2018
MAV2755AWW may tag washer Arrived on site to test unit for not working. Fiund unit not operating on any cycle. Found if plug is pushed at a certain angle while plugged into outlet unit would come on and operate as designed. Instruct customer on having outlet replaced by an electrician. No leaks detected.
Near Austin, TX 78701
Connor M.
Job Details: 04/24/2018
WFG530S0ES1 whirlpool oven Arrived on site to test unit for gas smell when not in use. Insoected all connections. Unit has already been bubble soaped by plumber. All connections checked fine visually. Tunred gas on and was unable to smell it until unit was moved. Gas line connected to range is slightly too short, causing tension to be put on it when moved. With out proper instrumentation i am unable to accurately locate leak. My guess would be related to the short gas line. If gas line is the root of cause it will need to be replaced by rhe builder as it is not considered part of the appliance. Instruct customer on cintacting gas company to have leak diagnosed with correct tools.
Near Cedar Park, TX 78613
Mike C.
Job Details: 04/24/2018
Whirlpool oven WOS51EC0AS04 Arrived to find unit not making any sound when making selections. Found user interface bad on unit. Installed new user interface and checked operation, checked good.
Near Copperas Cove, TX 76522
Steve C.
Job Details: 04/24/2018
Arrived on site for the unit will not turn on. Tested the unit and found the control is shorted. Replaced the control and calibrated the unit. Unit works properly and all water connections were dry at the time of service.
Near Austin, TX 78750
Paul
Job Details: 04/24/2018
KitchenAid Range Model KSGG700ESS1. Arrived onsite for the range that started smoking real bad when the oven was started and it’s coming from around the convection fan. I tested the oven and it is no longer smoking. I suspect that there was an extra amount of oil inside the cavity causing the issue. I removed the lower panel and the fan cover to make sure there was no packing in either place. The unit is working as designed. Call complete.
Near Austin, TX 78728
Nathaniel B.
Job Details: 04/24/2018
Model WOS51EC0AS04, Arrived on call for door out more on the left than the right, replaced outer oven door glass and frame glass and all checks good, control panel not needed, all checks good call complete, see pic. Instructed customer door will pull in more ounce they have had enough uses and it compresses gaskets more.
Near Austin, TX 78728
Nathaniel B.
Job Details: 04/24/2018
Model WOS51EC0AS04, Arrived on call for door out more on the left than the right, replaced outer oven door glass and frame glass and all checks good, control panel not needed, all checks good call complete, see pic. Instructed customer door will pull in more ounce they have had enough uses and it compresses gaskets more.
Near Spicewood, TX 78669
Luis
Job Details: 04/24/2018
Refrigerator-installed new icemaker
Near Canyon Lake, TX 78133
Daniel A.
Job Details: 04/24/2018
WCG97US0DS00 Center burner irregular flame. Yellow flame. Not burning properly. Inner and outer orifice reverses on center burner. Corrected orifice position. Normal operation after service. Verified proper ignition/flame
Near Lorena, TX 76655
Mike G.
Job Details: 04/24/2018
WRF736SDAM11, Arrived on site for unit not making ice checked unit and found that icemaker motor has stoped working unit icemaker will need to be replaced, replaced icemaker and checked unit and icemaker is now working and is calling for water checked unit for water leaks and no leaks found at time of srv.... unit checked fine at this time.....
Near Lorena, TX 76655
Mike G.
Job Details: 04/24/2018
WRF736SDAM11, Arrived on site for unit not making ice checked unit and found that icemaker motor has stoped working unit icemaker will need to be replaced, replaced icemaker and checked unit and icemaker is now working and is calling for water checked unit for water leaks and no leaks found at time of srv.... unit checked fine at this time.....
Near Belton, TX 76513
Dona
Job Details: 04/24/2018
Arrived on site for no operation, found thermal fuse, element, cutoff, thermistor, all checked good. Incoming power is correct. Timer is not sending voltage to motor or heater contacts are open. Erika assisted with parts and reschedule date. Dryer ducting clean.
Near New Braunfels, TX 78132
Connor M.
Job Details: 04/24/2018
WDT920SADM3 whirlpool dishwasher Arrived on site to test unit for leaking during wash. Found evidence of suds issue. Customer showed me video of unit during leak and inside was inundated with suds. Instruct on proper use and care. Unit working properly at time of service.
Near Killeen, TX 76541
Steve C.
Job Details: 04/24/2018
Arrived on site for the unit door is stuck and has error code f5e3. Tested the unit and found the door latch will make constant ticking noise. Found the latch is defective. Replaced the latch and tested the unit. Unit works properly and all water connections were dry at the time of service.
Near Killeen, TX 76541
Steve C.
Job Details: 04/24/2018
Arrived on site to replace the valve due to not filling up with water. Replaced the valve and tested the unit. Unit works properly and all water connections were dry at the time of service.
Near Georgetown, TX 78633
Thomas L.
Job Details: 04/24/2018
Near Kyle, TX 78640
Robert
Job Details: 04/24/2018
NED4655EW0 Amana dryer
Near Lampasas, TX 76550
Dona
Job Details: 04/23/2018
Arrived on site for fridge getting to 50 degrees, replaced door that was warped. Ran water through unit, verified no leaks. Thermistor checked good on ff evaporator. All operations checked good. Frost pattern looked good, customer had unit unplugged. Verified all water connections dry. Instructed customer to wait 24 hours before loading with food.
Near Bastrop, TX 78602
Nathaniel B.
Job Details: 04/23/2018
Model MVWC565FW0, Arrived on call for water level to low, found that on bulky unit is doing a deep water wash water is filling 4 inches bellow the inner rim of the inner tub which is correct amount of fill, found no error codes, found that customer was washing to large of comforters, instructed customer anything larger than a non bulky comforter will need to be taken to a laundry mat, gave customer instruct on soap usage and loading and cleaning of the washer, all checks good, no parts needed, call complete, hot and cold water are dispensing as they should.
Near Bastrop, TX 78602
Nathaniel B.
Job Details: 04/23/2018
Model MVWC565FW0, Arrived on call for water level to low, found that on bulky unit is doing a deep water wash water is filling 4 inches bellow the inner rim of the inner tub which is correct amount of fill, found no error codes, found that customer was washing to large of comforters, instructed customer anything larger than a non bulky comforter will need to be taken to a laundry mat, gave customer instruct on soap usage and loading and cleaning of the washer, all checks good, no parts needed, call complete, hot and cold water are dispensing as they should.
Near Leander, TX 78641
Lou
Job Details: 04/23/2018
arrived on site for dishwasher arm fallen off. Upon inspection, I found that the upper wash arm was broken and needed to be replaced. I inspected the manifold and found that it was good. I installed a new upper wash arm, tested the unit and the unit operates as designed. No water leaks observed during service.
Near Leander, TX 78641
Lou
Job Details: 04/23/2018
arrived on site to inspect microwave display. Upon further inspection, I could not reduplicate the issue; however, I inspected the control and found that the display ribbon was not seated correctly. I reseated the ribbon and tested unit and unit tested good. Job completed.
Near Leander, TX 78641
Lou
Job Details: 04/23/2018
Near Georgetown, TX 78633
Thomas L.
Job Details: 04/23/2018
Arrived on site for poor washing results. Customer told me dishes aren’t clean and she feels no heat after cycle. Found 2 fault. Does storeD. One for poor drain and one for no heat. Ran diagnostics and heater did work properly, 8 amps. Also found drain motor working properly. F8e1 F7e1 were codes. Reset control via diagnostics and error code F7e1.all operations are now normal. All water connections were dry.
Near Kyle, TX 78640
Robert
Job Details: 04/23/2018
Whirlpool microwave WMH32519CB0 replacement of magnetron
Near Waco, TX 76712
Mike G.
Job Details: 04/23/2018
EL7ATRRKS01, Arrived on site to install UV dryer and access valve after repair pulled a vacuum on system and unit Held vacuum put 4.1oz of 134a and checked for leaks and no leaks found at time of srv... and unit is starting to cool unit checked fine at this time....
Near Waco, TX 76712
Mike G.
Job Details: 04/23/2018
EL7ATRRKS01, Arrived on site to install UV dryer and access valve after repair pulled a vacuum on system and unit Held vacuum put 4.1oz of 134a and checked for leaks and no leaks found at time of srv... and unit is starting to cool unit checked fine at this time....
Near Austin, TX 78757
Cliff
Job Details: 04/23/2018
Whirlpool refrigerator WRT311FZDM00. Arrived on site to diagnose a refrigerator that is condensating in the fresh food section. Tested unit and found during installation of doors were reversed and door seals were not reshaped to accommodate for hinge position change. Reshaped seals using applied heat. Tested unit and found all is functioning properly at this time. No water leaks were found at time of service.
Near Pflugerville, TX 78660
Jonathan S
Job Details: 04/23/2018
Whirlpool dryer. Clumping clothes together and not drying.
Near Austin, TX 78749
Brandon
Job Details: 04/23/2018
Arrived on site for unit not heating, found bacteria-stat, I replaced cut off kit, unit tested good. Collected 245.85 on check. Instructed customer to have vent cleaned.
Near Cedar Park, TX 78613
Lou
Job Details: 04/23/2018
arrived on site for noisy washer. I placed the unit into diagnostic mode and the unit tested good. Ran manual test mode for high spin and found that the unit made a noise as if something was inside the tub. Stop test mode and checked inside the tub and found a penny in between the impeller and the basket. Removed the penny and tested unit again in manual mode on high spin and could not duplicate the noise. Advised customer of my findings. No water observed during service.
Near Kempner, TX 76539
Dona
Job Details: 04/23/2018
Arrived on site for no heat, found timer not sending voltage. Replaced timer, verified temperatures, unit checked good. Dryer ducting clear.
Near Copperas Cove, TX 76522
Dona
Job Details: 04/23/2018
Arrived on site for no cool conditions, found shorted defrost heater, open bimetal. Replaced defrost heater, bimetal and control, verified frost pattern is good. Temperatures dropping in fridge and freezer, airflow good to fridge side. Instructed customer to wait 24 hours for full cool before loading with food. All water connections dry.
Near Austin, TX 78745
Luis
Job Details: 04/23/2018
Refrigerator-replaced compressor
Near Austin, TX 78617
Robert
Job Details: 04/23/2018
W5CE3024XS00 Cooktop replacement of glass top
Near Volente, TX 78641
Lou
Job Details: 04/23/2018
arrived on site to install previously diagnosed and ordered parts. Removed and replaced the control, pantry control, UI, damper and evaporator cover. Also found that there was a 1/8 inch gap between the drain tube and the chassis. I used manufacturer approved silicone and sealed the gap. Tested unit and unit tested good. No water leaks observed during service. Customer had defrosted unit prior to service.
Near Waco, TX 76710
Mike G.
Job Details: 04/23/2018
WDTA50SAHW0, Arrived on site for unit not cleaning or drying checked unit and found 7-1 control turned off heating element checked unit and found that the OWI is bad and will need to be replaced ordering part checked unit for water leaks and no leaks found at time of srv..
Near Waco, TX 76710
Mike G.
Job Details: 04/23/2018
WDTA50SAHW0, Arrived on site for unit not cleaning or drying checked unit and found 7-1 control turned off heating element checked unit and found that the OWI is bad and will need to be replaced ordering part checked unit for water leaks and no leaks found at time of srv..
Near Dripping Springs, TX 78620
Brandon
Job Details: 04/23/2018
Arrived on site for dishwasher not cleaning, found power getting to wash motor, found bad wash motor. I replaced sump unit tested good, water lines were dry at time of service.
Near New Braunfels, TX 78130
Daniel A.
Job Details: 04/23/2018
KFIV29PCMS Not cooling/freezing. Refrigerant leak in refrigerator evaporator. Replaced evaporator/compressor. Compressor burnt out. Excessive oil leak. Verified normal operation after service. No refrigerant leaks detected.
Near Bertram, TX 78605
Thomas L.
Job Details: 04/23/2018
Arrived on site for no operation. Enter d diagnostics and found F1 failure. Replaced control per tech sheet. Unit tested fine after replacement of control Terri.harmon.atx@gmail.com
Near Round Rock, TX 78664
Nathaniel B.
Job Details: 04/23/2018
Model WFW92HEFW0, Arrived on call for Front display is not displaying properly, found that when set to towels only customer says display shows 9 hours, not able to repeat symptom, called whirlpool tech line and talked to dave, file number 7721805676, per whirlpool tech line have customer take video if issue returns and start cycle if it shows 9 hours and wait 15 min. And see if it still shows 9 hours, per dave from whirlpool not to install any parts today. Call complete, no water leaks at time of call.
Near Round Rock, TX 78664
Nathaniel B.
Job Details: 04/23/2018
Model WFW92HEFW0, Arrived on call for Front display is not displaying properly, found that when set to towels only customer says display shows 9 hours, not able to repeat symptom, called whirlpool tech line and talked to dave, file number 7721805676, per whirlpool tech line have customer take video if issue returns and start cycle if it shows 9 hours and wait 15 min. And see if it still shows 9 hours, per dave from whirlpool not to install any parts today. Call complete, no water leaks at time of call.
Near Austin, TX 78704
Robert
Job Details: 04/23/2018
WED7000DW Whirlpool dryer
Near Austin, TX 78704
Robert
Job Details: 04/23/2018
Near Kempner, TX 76539
Dona
Job Details: 04/23/2018
Arrived on site for not completing cycle, found drain pump Impellers not pushing water, units bearings are out, basket is wobbling, grinding on spin heavily. All water connections dry. Instructed customer not to use. Will need front tub, rear tub, seal, basket and pump. Will need authorization and will need two techs two hours. Left skype for office.
Near Horseshoe Bay, TX 78639
Thomas L.
Job Details: 04/23/2018
Arrived on site for no ice condition. Started unit to find it was spuing water out of the reservoir. Found the recirculating hose had come off of for recirculating pump. Reinstalled recirculating hose and tested unit. All water connections were dry at the time of service.
Near Killeen, TX 76542
Steve C.
Job Details: 04/23/2018
Arrived on site to replace the valve due to not filling up with water. Replaced the valve and tested the unit. Unit works properly and all water connections were dry at the time of service.
Near Killeen, TX 76542
Steve C.
Job Details: 04/23/2018
Arrived on site for the unit is not draining. Tested the unit and found the garbage disposal cap is still in place. Removed the cap and tested the unit. Unit works properly and all water connections were dry at the time of service.
Near Copperas Cove, TX 76522
Dona
Job Details: 04/23/2018
Arrived on site for unit not cleaning properly, found uppermost spray arm not attached to cabinet. Reseated unit now spraying correctly. Found dispenser not opening, replaced dispenser unit now opening. Found adjuster racks falling apart. Replaced adjusters and applicable parts with adjuster. Verified unit running to spec all operations checked good. All water connections dry.
Near Austin, TX 78731
Luis
Job Details: 04/23/2018
Redrigerator-door seal issues repaired
Near Temple, TX 76502
Dona
Job Details: 04/23/2018
Arrived on site for no heat on right front burner, found burned open right front burner. Replaced, verified operations, unit checked good. Infinite switch was not correct part pulled, sent pictures to Shana.
Near Temple, TX 76502
Mike G.
Job Details: 04/23/2018
KGRS505XSS05, Arrived on site for unit not heating checked unit and found that the bake ignitor is bad replaced ignitor and checked unit and unit is now heating unit checked fine at this time....
Near Temple, TX 76502
Mike G.
Job Details: 04/23/2018
KGRS505XSS05, Arrived on site for unit not heating checked unit and found that the bake ignitor is bad replaced ignitor and checked unit and unit is now heating unit checked fine at this time....
Near Morgan's Point Resort, TX 76513
Mike G.
Job Details: 04/21/2018
WED8000BW0, Arrived on site to install new dryer repair kit checked unit and cleaned out all lent found from unit and checked unit after repair and unit is now working properly unit checked fine at this time.....
Near Morgan's Point Resort, TX 76513
Mike G.
Job Details: 04/21/2018
WED8000BW0, Arrived on site to install new dryer repair kit checked unit and cleaned out all lent found from unit and checked unit after repair and unit is now working properly unit checked fine at this time.....
Near Bruceville-Eddy, TX 76524
Mike G.
Job Details: 04/21/2018
WTW7000DW1, Arrived on site for unit making a noise when washing checked unit and found that then unit is washing unit will start making a squeaking sound found that the bearings are going out unit will need the gearcase replaced ordering part checked unit for water leaks and no leaks found at time of srv....office will need to call customer to r/s
Near Bruceville-Eddy, TX 76524
Mike G.
Job Details: 04/21/2018
WTW7000DW1, Arrived on site for unit making a noise when washing checked unit and found that then unit is washing unit will start making a squeaking sound found that the bearings are going out unit will need the gearcase replaced ordering part checked unit for water leaks and no leaks found at time of srv....office will need to call customer to r/s
Near Georgetown, TX 78628
Thomas L.
Job Details: 04/20/2018
Arrived on site for improper operation. Found control board is powering up steam valve on all cycles and it is not turning water valve off. Customer doesn’t wish to invest this much in an 8year old dryer. Control $246.30 Work $189.99 Sub $436.29 Tax$ 35.99 Total$472.28
Near Kyle, TX 78640
Robert
Job Details: 04/20/2018
Refrigerator Whirlpool
Near Austin, TX 78735
Luis
Job Details: 04/20/2018
Wine cooler- replaced condenser fan motor and blade
Near Round Rock, TX 78665
Mike C.
Job Details: 04/20/2018
Kitchen Aid Refrigerator KRSC503ESS00 Arrived to check unit for not dispensing water or making ice. Checked voltage at primary inlet valve and found 120 volts. Found valve not opening. Installed new valve and checked operation, checked good with no water leaks.
Near Austin, TX 78737
Luis
Job Details: 04/20/2018
Refrigerator-replaced defrost sensor assembly
Near Austin, TX 78757
Joseph C.
Job Details: 04/20/2018
KDTE254ESS1 Arrived on site for “burning electrical smell” complaint. Inspected unit and found power wires, at junction box, to have burned through wire nuts. Performed repairs to wires. Tested unit. Unit is performing as designed. No leaks detected, at time of service.
Near Killeen, TX 76542
Dona
Job Details: 04/20/2018
Arrived on site to replace leaking housing. Replaced housing, filled unit, unit agitated, drained and spun with no leaks. Verified all water connections dry.
Near Pflugerville, TX 78660
Nathaniel B.
Job Details: 04/20/2018
Model MFF2558VEB1, Arrived on call for unit not cooling properly, installed used test relay prior and left it on the unit prior to leaving location on last call and when got to customers home unit has been running and has not shut off and freezer is 5 degrees and fresh food is 37 degrees and compressor is just warm and compressor is drawing 0.9 amps which is good and compressor windings were less than 1 ohm difference on readings on previous call, per gc senior tech only install cap and start device, sealed system parts not needed, no water leaks at time of call, call complete.
Near Pflugerville, TX 78660
Nathaniel B.
Job Details: 04/20/2018
Model MFF2558VEB1, Arrived on call for unit not cooling properly, installed used test relay prior and left it on the unit prior to leaving location on last call and when got to customers home unit has been running and has not shut off and freezer is 5 degrees and fresh food is 37 degrees and compressor is just warm and compressor is drawing 0.9 amps which is good and compressor windings were less than 1 ohm difference on readings on previous call, per gc senior tech only install cap and start device, sealed system parts not needed, no water leaks at time of call, call complete.
Near Austin, TX 78739
Luis
Job Details: 04/20/2018
Test
Near Austin, TX 78739
Luis
Job Details: 04/20/2018
Refrigerator-replaced icemaker assembly