Near Marble Falls, TX 78654
Thomas L.
Job Details:
02/19/2018
Arrived on site for flashing service light, found open thermostat.Replaced thermostat. Unit started cycling error stopped. All water connections dry.
Control $45.79
Work $149.99
Sub $195.78
Tax $16.15
Total $211.93
Near Austin, TX 78759
Cliff
Job Details:
02/19/2018
Jennair oven JJW3830DS00, Arrived on site to diagnose an oven that will not update with Jenn air through Wi-Fi. Tested unit and found Wi-Fi board not operating properly and preventing update. Replaced control panel and tested unit. Found unit is now connected to jennair service properly and all is operating properly at this time.
Near Horseshoe Bay, TX 78657
Thomas L.
Job Details:
02/19/2018
Arrived for no ice production, found ice paddle on door with incorrect dc voltage. Replaced verified ops checked good. Replaced ice bin on door that was broken. All water connections dry.
Near Leander, TX 78641
Jerry C.
Job Details:
02/19/2018
KRFC704FBS00 arrived on site to install previously diagnosed and ordered parts. Use heat to reform new gasket. Once verified replacement gasket in condition to install, removed and replaced old gasket with new. No leaks found during service; all connections were dry.
Near Harker Heights, TX 76548
Mike G.
Job Details:
02/19/2018
GS6NHAXVA00 , Arrived on site for unit not making ice checked unit and found that the icemaker is working and when icemaker calls for water water is spraying out of the side checked unit and found that the fill chut to icemaker is blocked with ice and froze up removed icemaker and flushed out icemaker and checked unit and found that the unit checked fine at this time.... checked unit for water leaks and no leaks found at time of srv....
Near Harker Heights, TX 76548
Mike G.
Job Details:
02/19/2018
GS6NHAXVA00 , Arrived on site for unit not making ice checked unit and found that the icemaker is working and when icemaker calls for water water is spraying out of the side checked unit and found that the fill chut to icemaker is blocked with ice and froze up removed icemaker and flushed out icemaker and checked unit and found that the unit checked fine at this time.... checked unit for water leaks and no leaks found at time of srv....
Near Kingsland, TX 78639
Thomas L.
Job Details:
02/19/2018
Arrived on site for dripping water and ice build up in freezer, found bowed door and un malleable gasket. Replaced door and seal, verified ops unit did ok. Water connections dry.
Near Georgetown, TX 78633
Thomas L.
Job Details:
02/17/2018
Arrived on site to install parts. Replaced opened fuse and slow turning fan motor. Tested unit and unit operated as designed.
Near Killeen, TX 76543
Thomas L.
Job Details:
02/17/2018
Arrived on site to install parts. Tested unit and found motor would not start on its own. Removed and installed motor and blower wheel. Tested unit and unit operated as designed.
Near Nolanville, TX 76559
Thomas L.
Job Details:
02/17/2018
Arrived on site to install part. Tested unit in service mode and 7-1 code appeared. Ran diagnostics to clear control and customer is able to run unit. No leaks found; all connections were dry.
Near Belton, TX 76513
Thomas L.
Job Details:
02/17/2018
Arrived on site to install parts. Installed open components per manufacturer. Will also need to install fan and thermostat. Office to order parts and reschedule. Microwave was not installed properly and sitting on the countertop in the unplugged position. Left unit unplugged at end of service.
Near Belton, TX 76513
Thomas L.
Job Details:
02/17/2018
Arrived on site for dispenser leaking and rusting. Found that the dispenser was jammed; unjammed the dispenser and it works as designed. Both doors have rust on facing and customer will report this to his extended warranty company. No leaks observed and customer reported no leaks. All connections were dry.
Near Temple, TX 76502
Thomas L.
Job Details:
02/17/2018
Arrived on site for dispenser leaking and rusting. Found that the dispenser was jammed; unjammed the dispenser and it works as designed. Both doors have rust on facing and customer will report this to his extended warranty company. No leaks observed and customer reported no leaks. All connections were dry.
Near Cedar Park, TX 78613
Jerry C.
Job Details:
02/16/2018
WTW5000DW1 arrived on site for a washer making a high pitched noise in the spin cycle. Tested unit in the service mode on the spin cycle and found the unit required cabinet adjustment and hardware tightening. Adjusted/tightened hardware, tested unit and operated correctly. The unit required the basket centered within chassis. No leaks found all connections were dry.
Near Georgetown, TX 78633
Thomas L.
Job Details:
02/16/2018
Replaced leaking icemaker, all connections dry.
Near Marble Falls, TX 78654
Thomas L.
Job Details:
02/16/2018
Arrived on site to replace shorted board that was caused by shorted pump, replaced both, unit recalibrated unit checked ok, in warehouse not hooked to water.
Near Austin, TX 78726
Jerry C.
Job Details:
02/16/2018
WRT311FZDM00 arrived to install part. Removed and replaced existing extension and tested. During service, I found large amount of moisture on the ceiling of fc. The left side of the fc door gasket was gapped one quarter inch along its entirety. I was able to re-bed the gasket and get it to seal correctly, through multiple tests. Advised customer to contact us if excessive moisture persists within the chassis. Operations are good; no leaks; all connections dry.
Near Marble Falls, TX 78654
Thomas L.
Job Details:
02/16/2018
Arrived on site for a no run condition, found loose L1 on cord, corrected loose wire. Unit started up and started to cool. Water connections all dry.
Near Burnet, TX 78611
Thomas L.
Job Details:
02/16/2018
Arrived on site for no ice production replaced, valve and housing. Verified all connections dry.
Near Burnet, TX 78611
Thomas L.
Job Details:
02/16/2018
Arrived on site for no drain, found no issues at this time, ran through cycle wash, fill, drain, and spin all work to spec. All water connections dry.
Near Seguin, TX 78155
Connor M.
Job Details:
02/16/2018
WTW5000DW1 whirlpool washer Arrived on site to test unit for clothes still wet at end of cycle. Found loose connection at drain pump. Repaired and tested unit. No leaks detetced.
Near McQueeney, TX 78123
Connor M.
Job Details:
02/16/2018
WTW8000DW3 whirlpool washer Arrived on site to test unit for loud operation. Found unit operating with normal sound levels. No issues found. Instruct on proper use and function. No leaks detetced.
Near Bertram, TX 78605
Thomas L.
Job Details:
02/16/2018
Arrived on site for inconsistent spin cycle, found lid strike loose, reseated and tightened. Verified ops, unit ran through cycle. All water connections dry.
Near Bertram, TX 78605
Thomas L.
Job Details:
02/16/2018
Arrived on site for no heat, found open heating element, replaced verified operations. Ducting is cleaned.
Near Manchaca, TX 78652
Connor M.
Job Details:
02/15/2018
WRT549SZDM01 whirlpool refrigerator Arrived on site to test unit for no ice production. Found no water coming to icemaker when called for. Found valve not plugged in to harness in rear of unit. Corrected issue and tested. Unit working properly, no leaks detected.
Near Jarrell, TX 76537
Thomas L.
Job Details:
02/15/2018
Arrived on site for repair from previous visit, customer informed appliance express that the unit had already been replaced.
Near Austin, TX 78735
Connor M.
Job Details:
02/15/2018
MVWC500VW0 maytag washer Arrived on site to install parts for reapir. Installed cogs and coupling. Unit working properly, no leaks detected.
Near Cedar Park, TX 78613
Jerry C.
Job Details:
02/15/2018
MSD2550VES00- Arrived on site for ice dispenser frozen up and fridge needing a filter. Removed current filter to find that it was not engaged fully. Engaged filter and purged water line. Was able to remove ice bin and thawed out ice and found no issues with ice maker. Reinstalled ice bin and tested Unit and no issues. No water leaks found; all connections dry. Customer paid service call and removal of frozen ice fee total of $162.36.
Near Belton, TX 76513
Thomas L.
Job Details:
02/15/2018
Arrived on site for no spin, found OL-f70 error removed washplate found plate worn down will not stay on shaft through cycle. Will not allow for spin. Ordering wpw10286241 Callie assisted.
Near Belton, TX 76513
Thomas L.
Job Details:
02/15/2018
Arrived on site for failed control and open valve, replaced both. Unit checked good. Verified all dry water connections. Customer had paid in full at last visit.
Near Dripping Springs, TX 78620
Connor M.
Job Details:
02/15/2018
MGDX655DW maytag dryer Arrived on site to test unit for long dry times. Found loose connection on coil. Once working discovered evidence of poor air flow. Ran vent test and unit failed. Found lint on wrong side of screen. Customer has already replaced duct work in house. House was recently built. Suspected issue with internal venting to be rectified by builder. Made customer aware of fire hazard and proper venting.
Near Cedar Park, TX 78613
Jerry C.
Job Details:
02/15/2018
KHMS2056SSS2 Arrived to inspect no lights and fan operation. The lights would not actuate and the relay could not be heard, even though the main control showed light actuation. The blower would work, but the buttons were intermittent. One of the lamp housings is broken. Office to order the control relay board, button board and lamp housing will be installed upon return. I quoted the customer for the relay board $161.07, button board $61.20 and lamp housing $4.46 MW120 $269.99 minus $10 senior discount. Total with tax included $526.87. The customer paid $108.24, balance of $418.63. 02/21SW
Near Belton, TX 76513
Thomas L.
Job Details:
02/15/2018
Arrived on site for no heat on high, found temp lock switch not in alignment with opening on control panel. Causing no adjustment control on switch on high. Reseated verified temps unit checked good. Inside dryer venting was clean.
Near Austin, TX 78737
Connor M.
Job Details:
02/15/2018
KRFF305ESS00 kitchenaid refrigerator Arrived on site to test unit for no ice production. Found ice level arm out of position at ice maker. Corrected issue and forced harvest. Unit harvesting and filling properly. No leaks detetced.
Near Austin, TX 78717
Jerry C.
Job Details:
02/15/2018
MVWB765FW0- Arrived to install gear case. Verified squeaking noise from gear case; removed old part and installed new gear case. Calibrated Unit; tested in Manual and automatic test modes. Operational tests good; no leaks during service.
Near Austin, TX 78749
Connor M.
Job Details:
02/15/2018
NTW4516FW2 Amana washer Arrived on site to test unit for not completeing cycles. Confirmed proper function of all components. No error codes stored. Will need to replace control for repair. Control is an expart. Office to schedule directly.
Near Austin, TX 78745
Connor M.
Job Details:
02/15/2018
MGDC215EW maytag dryer Arrived on site to test unit for not drying well on auto dry. Found customer using auto dry as a touch up cycle. Not intended for use like this. Confirmed proper function of all components and instruct on proper use. Unit working properly. Made aware of proper venting and fire hazard.
Near Salado, TX 76571
Thomas L.
Job Details:
02/15/2018
Arrived on site for improper cooking function, when testing found door rattling. Tightened door screw unit is now workin to spec.
Near Leander, TX 78641
Jerry C.
Job Details:
02/15/2018
WDF330PAHW1 arrived on site to install part. I found the dispenser intact and there were no signs of water leakage when the panel was removed. The unit was tilted badly to the right and to the front as well. After leveling the chassis, the water leak, which was coming from the door lower vents, was completely cured. Operational test good, no leaks observed during service. Service was originally contacted prior to the 30 day installation limit.
Near Austin, TX 78739
Connor M.
Job Details:
02/15/2018
Arrived on site to test unit for wash cycle not working. Found only aggitator moving during spin. Error code for shifter failure aswell. Ordering clutch and slider for repair. Office approved 2/20 CM only please WTW8700EC0 whirlpool washer
Near Austin, TX 78739
Connor M.
Job Details:
02/15/2018
MVWX655DW1 maytag washer Arrived on site to test unit for ripping clothes during cycle. Confirmed proper water flow and fill. Found washplate slightly off center. Replaced and instruct on proper cycle usage and loading techniques. Unit working properly, no leaks detected.
Near Temple, TX 76501
Mike G.
Job Details:
02/15/2018
WTW5000DW1, Arrived on site for unit leaking, checked unit and found that the gearcase is leaking oil and needs to be replaced, replaced gearcase and checked unit after repair and unit checked fine at this time, chcked unit for water leaks and no leaks found at time of srv..
Near Temple, TX 76501
Mike G.
Job Details:
02/15/2018
WTW5000DW1, Arrived on site for unit leaking, checked unit and found that the gearcase is leaking oil and needs to be replaced, replaced gearcase and checked unit after repair and unit checked fine at this time, chcked unit for water leaks and no leaks found at time of srv..
Near Cedar Park, TX 78613
Jerry C.
Job Details:
02/14/2018
MVWX655DW1 Arrived to inspect unit not draining. I found debris blocking the drain and removed it. The unit worked correctly through multiple tests. Operational test good, no leaks observed during service. TL100 $139.99
Near Bertram, TX 78605
Thomas L.
Job Details:
02/14/2018
Arrived on site for no cool, replaced grounded compressor, and cracked suction line. Recharged, tested, unit cooling. Not hooked up to water
Near Blanco, TX 78606
Daniel A.
Job Details:
02/14/2018
WTW5000DW1 Not washing/rinsing clothes. Defective cold solenoid on inlet valve. Not allowing cold water to enter washer to advance rinse cycle Replaced solenoid/inlet valve assembly. Checked water inlet and drain hoses. No leaks detected. Ran wash cycle. Normal fill hot-cold during operation
Near Austin, TX 78717
Jerry C.
Job Details:
02/14/2018
WDF520PADM7 Arrived on site for a dishwasher door not staying open. Found that the friction pad was split. Installed new friction pad; adjusted spring and door operates as designed. No leaks observed during service.
Near Round Rock, TX 78665
Jonathan S
Job Details:
02/14/2018
Whirlpool range model # WFC150M0EW1. Not heating to preheat temperature.
Near Burnet, TX 78611
Thomas L.
Job Details:
02/14/2018
Arrived on site for front load washer that would not unlock, found non operative door latch, replaced door latch verified operations. Checked water connections verified them as dry.
Near Hutto, TX 78634
Jonathan S
Job Details:
02/14/2018
Whirlpool microwave model #WMH32519FB0. Interior light is flickering .
Near Kingsland, TX 78639
Thomas L.
Job Details:
02/14/2018
Arrived on site for no lights in unit. Replaced light sensor board, verified operations. All ops checked good water connections dry.
Near Hutto, TX 78634
Jonathan S
Job Details:
02/14/2018
Whirlpool refrigerator model# WRX735SDBM00. Making loud noises.
Near Kingsland, TX 78639
Thomas L.
Job Details:
02/14/2018
Arrived on site after unit had been removed by customer from cabinet. Unit is now working has no known issues at this time, after having ran numerous times.
Near Horseshoe Bay, TX 78657
Thomas L.
Job Details:
02/14/2018
Arrived on site for abnormal heal fluctuations, foundheat relay error, replaced control, will return core part. Verified temps, unit could ok. Dryer vent is clean.
Near Leander, TX 78641
Jerry C.
Job Details:
02/13/2018
Arrived on site for incorrect flame. Tested Unit and found debris in orifaces holder. Advised customer how to clean and remove debris for future reference. Described and showed customer how to properly place burner caps. Operational test good; no gas leaks detected during service.
Near Georgetown, TX 78633
Thomas L.
Job Details:
02/13/2018
Arrived on site for no lock issue, found lock non operational. Replaced lock, verified operations, checked all water connections were dry.
Near Cedar Park, TX 78613
Jerry C.
Job Details:
02/13/2018
Arrived on site for cooktop not igniting. Tested The spark module and was not reading 120 volts. Tested the power source outlet and found that the outlet was not reading 120 volts; approx. 14.5 volts. When plug was moved, voltage would jump to 122.5 volts. Customer will need to contact an electrician to replace power source outlet. No gas leaks found.
Near Austin, TX 78749
Connor M.
Job Details:
02/13/2018
WTW4815EW0 whirlpool washer Arrived on site to test unit for not rinsing clothes well. Found error code for open motor winding. No other issues found. Ordering motor for return. Sw approved monday
Near Liberty Hill, TX 78642
Thomas L.
Job Details:
02/13/2018
Arrived on site for no functionally of Unit, found wiring incorrect from install, corrected wiring and checked operation unit check ok.
Near Austin, TX 78717
Jerry C.
Job Details:
02/13/2018
Arrived on site for a dishwasher not cleaning well. After further inspection of the Unit, found that the Unit was clogged. Cleaned the chopper and housing and filter. Tested Unit and Unit operates as designed. Found no water leaks; all connections were dry. DW510 $139.99.
Near Austin, TX 78735
Connor M.
Job Details:
02/13/2018
MVWC416FW1 maytag washer Arrived on site to test unit for loud noise during operation. Found motor housing loose and rubbing on gear. Corrected issue and tested unit. Unit working properly, no leaks detetced.
Near Granite Shoals, TX 78654
Thomas L.
Job Details:
02/13/2018
Arrived on site for no spin issues, ran unit through cycle that customer had started found customer had selected no spin. Adjusted cycle explained functions of operation choice all water connections dry.
Near Granite Shoals, TX 78654
Thomas L.
Job Details:
02/13/2018
Near Austin, TX 78717
Jerry C.
Job Details:
02/13/2018
Arrived on site for a dishwasher not working/lighting up. Checked the voltage and it was good. Checked the user interface connection to control board and found corrosion on user interface. Verified 5 VCC and then Installed new user interface and it came on. Tested Unit and it operated as designed. Found no water leaks; all connections were dry.
Near Austin, TX 78741
Connor M.
Job Details:
02/13/2018
WED85HEFC whirlpool dryer Arrived on site to test unit for no heat. Found improper voltage at house supply. Instruct on contacting an electrician. Made aware of proper venting and fire hazrads.
Near Austin, TX 78741
Connor M.
Job Details:
02/13/2018
MVWX655DW1 maytag washer Arrived on site to test unit for loud clicking noise. Found loose nut on drive shaft. Tightend with loc tite and tested unit. No leaks detetced.
Near Austin, TX 78741
Connor M.
Job Details:
02/13/2018
WMH53520CS7 whirlpool microwave Arrived on site to test unit for fan not working. Found fan would spin if i assisted it in starting. Once at a complete stop it would not start spinning by itself. Will need to reaplce fan. Ordering control if needed. Fan is expart, office to schedule directly.
Near Liberty Hill, TX 78642
Thomas L.
Job Details:
02/13/2018
Arrived on site, checked for leaks, verified operation found no leaks all operations checked good. Took pictures of assembly below and connections. No damage. New home not lived in
Near Georgetown, TX 78633
Thomas L.
Job Details:
02/13/2018
Arrived on site for poor washability and upper rack not closing properly. Found that the left upper rack stop had fallen off. Reinstalled and tested Unit. All operations were normal and all water connections were dry.
Near Pflugerville, TX 78660
Chase
Job Details:
02/12/2018
WEF75HEFW
Near Wimberley, TX 78676
Connor M.
Job Details:
02/12/2018
KDTE254ESS1 kitchenaid dishwasher Installed owi and drain pump. Unit working properly, no leaks detetced.
Near Wimberley, TX 78676
Connor M.
Job Details:
02/12/2018
WFW95HEDW0 whirlpool washer Arrived on site to install parts for repair. Installed dispenser and cover. Tested in all cycles with top off. No leaks found. Unit working properly, no leaks detetced.
Near Wimberley, TX 78676
Connor M.
Job Details:
02/12/2018
KFIV29PCMS02 kitchenaid refrigerator Installed door and set gasket. Unit working properly, no leaks detected.
Near Wimberley, TX 78676
Connor M.
Job Details:
02/12/2018
WTW5000DW1 whirlpool washer Arrived on site to test unit for low water levels. Found customer had soil level on extra light even on large cycles. Ran diagnostic test found error for water lines switched. Swapped cold and hot and tested unit. Unit working properly, no leaks detetced.
Near Wimberley, TX 78676
Connor M.
Job Details:
02/12/2018
GEW9200LW1 whirlpool dryer Arrived on site to test unit for long dry times. Found duct from dryer to house vent partially clogged. Removed vent and unit ran fine. Small amount of noise associated with the age of unit during operation. Instruct on replacing duct to repair. Made aware of fire hazard. Collected service only.
Near Temple, TX 76504
Mike G.
Job Details:
02/10/2018
WED5000DW2, Arrived on site for unit not heating, checked unit and found that the unit is not getting 240v found from L1 to G getting 120v and from L2 to G getting 120v from L1 to L2 getting 0v found it to Be a electrical issue customer will need electrician to repair checked and cleaned out all lent found from unit unit checked fine at this time...
Near Temple, TX 76504
Mike G.
Job Details:
02/10/2018
WED5000DW2, Arrived on site for unit not heating, checked unit and found that the unit is not getting 240v found from L1 to G getting 120v and from L2 to G getting 120v from L1 to L2 getting 0v found it to Be a electrical issue customer will need electrician to repair checked and cleaned out all lent found from unit unit checked fine at this time...
Near Temple, TX 76504
Mike G.
Job Details:
02/10/2018
WED5000DW2, Arrived on site for unit not heating, checked unit and found that the unit is not getting 240v found from L1 to G getting 120v and from L2 to G getting 120v from L1 to L2 getting 0v found it to Be a electrical issue customer will need electrician to repair checked and cleaned out all lent found from unit unit checked fine at this time...
Near Temple, TX 76504
Mike G.
Job Details:
02/10/2018
WED5000DW2, Arrived on site for unit not heating, checked unit and found that the unit is not getting 240v found from L1 to G getting 120v and from L2 to G getting 120v from L1 to L2 getting 0v found it to Be a electrical issue customer will need electrician to repair checked and cleaned out all lent found from unit unit checked fine at this time...
Near Georgetown, TX 78628
Chase
Job Details:
02/09/2018
DU8700XY5 arrived on site and replace door gasket and deflectors. Test it dishwasher and no water leaks present after repairs were completed
Near Austin, TX 78744
Connor M.
Job Details:
02/09/2018
WTW4915EW1 whirlpool washer Arrived on site to install drain pump for repair. Emptied water and installed. Unit working properly, no leaks detected.
Near Austin, TX 78744
Connor M.
Job Details:
02/09/2018
CAE2745FQ0 whirlpool washer TL110-189.99 arrived on site to install actuator for repair. Installed and tested unit. Unit working properly, no leaks detetced.
Near Austin, TX 78741
Connor M.
Job Details:
02/09/2018
WTW4815EW1 whirlpool washer Arrived on site to test unit for not spinning out. Found error code for off balance load. Ran spin cycle and found no mechanical frictionon drive. Unit is balanced and suspension is even. No issues found. No leaks detetced.
Near Austin, TX 78749
Connor M.
Job Details:
02/09/2018
DU8550XX1 whirlpool dishwasher Arrived on site to test unit for latch issue. Found latch for dispenser worn out. Also found leak in rinse aid dispenser. Replaced both parts and tested unit. Unit working properly, no leaks detetced.
Near Austin, TX 78748
Connor M.
Job Details:
02/09/2018
MVWX655DW1 maytag washer Arrived on site to install parts for repair. Installed control and latch. Unit working properly, no leaks detetced.
Near Round Rock, TX 78665
Jonathan S
Job Details:
02/09/2018
Whirlpool washer model# WTW5840BW0. Not spinning
Near Wimberley, TX 78676
Connor M.
Job Details:
02/09/2018
MHW7100DW0 maytag washer FL250-169.99 arrived on site to test unit for suds error.mfound unit draining very slowly. Cleaned drain filter and tested unit. Unit working properly, no leaks detetced. Collected labor via cc.
Near Liberty Hill, TX 78642
Mike C.
Job Details:
02/09/2018
Arrived on site for an F9 error code for bad wiring on a range. Checked voltage at power source and was 250 volts. Checked wiring on range and it was good and found the control was bad. Installed new control board and tested. Unit is operating as designed.
Near Austin, TX 78754
Chase
Job Details:
02/08/2018
WDF520PADM arrived on site to check dishwasher for intermittent power issues and blinking lights on control panel. Customer stated that start light with flash and when pressed the whole unit would go blank and not respond. Checked wiring at terminal block and found large wire nut for neutral wire with a loose connection. Replaced electronic control due to possible damage from backfeed through neutral wire. Rent s cycle and all functions of dishwasher check good
Near Austin, TX 78754
Chase
Job Details:
02/08/2018
MVW655DW1 arrived on site to check washer for no operation. Found standing water inside tub period removed all water and inspected drain pump. Found impeller bearing broken. Also found gearcase shaft had dropped causing pulley to rub on machine cover. Will need to replace drain pump and gear case to repair washer
Near Waco, TX 76712
Mike G.
Job Details:
02/08/2018
WED9500TW3, Arrived on site for unit not heating checked unit and found that the element and fuse are bad replaced parts and checked and cleaned out all lent found from unit and tested unit and unit is now heating fuse $25.40, element $113.49, DR560 $159.99 = $298.88 + tax
Near Waco, TX 76712
Mike G.
Job Details:
02/08/2018
WED9500TW3, Arrived on site for unit not heating checked unit and found that the element and fuse are bad replaced parts and checked and cleaned out all lent found from unit and tested unit and unit is now heating fuse $25.40, element $113.49, DR560 $159.99 = $298.88 + tax
Near Austin, TX 78754
Chase
Job Details:
02/08/2018
WED75HEFW arrived on site to check dryer for no heat. Checked thermostats and heating element and they checked good. Verify proper voltage at wall outlet. Inspected wiring at terminal block and found L to side of power cord broken off exposing bare wire. Advise customer that power cord would need to be replaced and unit should not be plugged in.
Near Austin, TX 78723
Chase
Job Details:
02/08/2018
WRF981BOOM arrived on site to check refrigerator for no ice production and frosting in freezer. Found missing segments on user interface display and compressor running during Diagnostics. Owned wiring in door and it checked good. Sound compressor with internal ticking noise and constantly ramping up to high speed and then lowering down. Inform customer that Electronics would need to be replaced to further diagnose other issues
Near Austin, TX 78723
Chase
Job Details:
02/08/2018
Near Georgetown, TX 78633
Mike C.
Job Details:
02/08/2018
Arrived on site to install switches, interlocks, and cams on a microwave. All items installed; Unit tested and operates as designed.
Near Austin, TX 78723
Chase
Job Details:
02/08/2018
UXT5530AAS arrived on site to check vent hood for vibration noise. Found noise would occur when blower speed was reduced from high to low. Replaced blower and tested multiple times. After replacement all functions a vent Hood check good. There must have been a failure of the internal motor bearing or defect in mounting brackets
Near Georgetown, TX 78628
Mike C.
Job Details:
02/08/2018
Arrived on site for dishwasher with no power. Found that the power switch had been turned to the off position. Turned power on; tested Unit and it operated as designed. No leaks found; all connections were dry.
Near Austin, TX 78723
Chase
Job Details:
02/08/2018
WMH32519CS arrived on site and checked microwave for open / closed door error. Inspected microwave frame and switches. Found normally open switch body had separated. Due to frequency of error replace both upper and lower inner locks as well as all three switches. Tested all functions of microwave and all check good after repair
Near Georgetown, TX 78628
Mike C.
Job Details:
02/08/2018
Arrived on site to install ice maker and water filter cap. Tested Unit and operated as designed. No leaks found; all connections were dry.