Near Austin, TX 78748
Luis
Job Details: 05/23/2018
Refrigerator-replaced diffuser and temp sensor
Near Austin, TX 78748
Connor M.
Job Details: 05/23/2018
MVWB835DW0 maytag washer File number-7722061595 arrived on site to test unit for not completing cycle. Found error code f8e6 water hazard fault. Tested valves, lid switch, and drain. Drian hose is not syphoning and is installed correctly. Water valves all operating normal. Blew through pressure hose and it was not obstructed. Plugged one end of hose and there were no leaks. Ordering pressure hose per techline. SW approved 5/29
Near Kingsland, TX 78639
Thomas L.
Job Details: 05/23/2018
Arrived on site for improper water fill. Calibrated control in step 4. Tested u it functions in step 2.all were corrected. Tested fill cycle in normal and deep water wash. Unit still not filling properly. Replaced control and all operations now work properly with no water leaks.
Near Dripping Springs, TX 78620
Brandon
Job Details: 05/23/2018
Arrived on site for part hanger, I replaced washplate and removed loose change, unit tested good, no water leaks at time of service.
Near Kingsland, TX 78639
Thomas L.
Job Details: 05/23/2018
Arrived on site for improper water fill. Calibrated control in step 4. Tested u it functions in step 2.all were corrected. Tested fill cycle in normal and deep water wash. Unit still not filling properly. Replaced control and all operations now work properly with no water leaks.
Near Kingsland, TX 78639
Thomas L.
Job Details: 05/23/2018
Ginnyharned@yahoo.com Arrived on site for icing condition. Customer defrost unit several weeks ago. Removed cover and frost pattern was good. Entered defrost cycle via diagnostics and it worked properly. Can not determine at this time which component function improperly. No water hooked up to this unit.
Near Dripping Springs, TX 78620
Brandon
Job Details: 05/23/2018
Arrived on site for part hanger, I replaced fan switch and knob, unit tested good.
Near Austin, TX 78753
Joseph C.
Job Details: 05/23/2018
IRT138FDM00 Arrived on site for “not cooling and making hissing noises” complaint. Inspected unit and found hole in first bend in process tube. Found rear cover missing and right rear wheel shattered. Ordering new. Will need to be sealed system/two hour call.
Near Burnet, TX 78611
Steve C.
Job Details: 05/23/2018
Arrived on site for the unit has error code LF. Tested the unit in diagnostics and received error code f3e2 valve thermistor short, and f8e1 long fill. Found the valve is defective. Replaced the valve and calibrated the unit. Unit works properly and all water connections were dry at the time of service.
Near Austin, TX 78704
Luis
Job Details: 05/23/2018
Refrigerator-replaced defrost sensor assembly
Near Austin, TX 78704
Connor M.
Job Details: 05/23/2018
WFW8300SW02 whirlpool washer Part-132.50 FL570-189.99 arrived on site to test unit for shaking and bumping when in spin. Found shocks worn out. Will need to replace. JA approved 5/29
Near Pflugerville, TX 78660
Nathaniel B.
Job Details: 05/23/2018
Model WTW7600XW0, Arrived on call for rps sensor failure, replaced rps sensor and error did not return in rinse/drain/ spin, also found bearing is bad and log valve is putting in to much water will need to order log valve and hub and use bearing and tool on return, will schedule for 2 hour, Skyped office parts and talked to Jordan and office will reschedule with customer.
Near Pflugerville, TX 78660
Nathaniel B.
Job Details: 05/23/2018
Model WTW7600XW0, Arrived on call for rps sensor failure, replaced rps sensor and error did not return in rinse/drain/ spin, also found bearing is bad and log valve is putting in to much water will need to order log valve and hub and use bearing and tool on return, will schedule for 2 hour, Skyped office parts and talked to Jordan and office will reschedule with customer.
Near Georgetown, TX 78633
Mike G.
Job Details: 05/23/2018
WDT720PADM2, Arrived on site for unit door will not shut, checked unit and found that the top rack is not setting in the unit properly found that the back ajuster on the left hand side had popped off of the rack and just hanging on the track removed top rack from the tracks and removed ajuster from track and reinstalled ajuster onto the top rack and reinstalled rack into the unit and checked unit and unit door is now latching checked unit for water leaks and no leaks found at time of srv....
Near Georgetown, TX 78633
Mike G.
Job Details: 05/23/2018
WDT720PADM2, Arrived on site for unit door will not shut, checked unit and found that the top rack is not setting in the unit properly found that the back ajuster on the left hand side had popped off of the rack and just hanging on the track removed top rack from the tracks and removed ajuster from track and reinstalled ajuster onto the top rack and reinstalled rack into the unit and checked unit and unit door is now latching checked unit for water leaks and no leaks found at time of srv....
Near Kingsland, TX 78639
Thomas L.
Job Details: 05/23/2018
Ginnyharned@yahoo.com Arrived on site for icing condition. Customer defrost unit several weeks ago. Removed cover and frost pattern was good. Entered defrost cycle via diagnostics and it worked properly. Can not determine at this time which component function improperly. No water hooked up to this unit.
Near Georgetown, TX 78633
Mike G.
Job Details: 05/23/2018
JFC2089BEM01, Arrived on site for unit getting frost in freezer, checked unit and found frost in the front left side of the freezer found that the freezer door was not shut all the way talked to customer about not opening freezer door from the left hand side of freezer door handle found no gaps around liner of freezer door and freezer door is sealing properly checked unit for water leaks and no leaks found at time of srv.... unit checked fine at this time.....
Near Georgetown, TX 78633
Mike G.
Job Details: 05/23/2018
JFC2089BEM01, Arrived on site for unit getting frost in freezer, checked unit and found frost in the front left side of the freezer found that the freezer door was not shut all the way talked to customer about not opening freezer door from the left hand side of freezer door handle found no gaps around liner of freezer door and freezer door is sealing properly checked unit for water leaks and no leaks found at time of srv.... unit checked fine at this time.....
Near Killeen, TX 76549
Dona
Job Details: 05/23/2018
Arrived on site for no blower fan operation, and no light under unit, found burned out bulb will need 40 watt lamp. Found grill vent is broken off of unit. Will need grill vent, found low voltage from control to blower fan motor, fan motor is open. Will need to replace control- showing as discontinued and will need to replace electronic control. Will need authorization for repair as well as one warranty to find the electronic control. AB assisted with parts. Instructed customer not to be using microwave due to unit could overheat.
Near Dripping Springs, TX 78620
Brandon
Job Details: 05/23/2018
Arrived on site for part hanger, I replaced part, unit tested good.
Near Cedar Park, TX 78613
Lou
Job Details: 05/23/2018
arrived on site to install previously diagnosed and ordered part. Removed and replaced the door switch. Tested unit and unit tested good. No lint observed during service.
Near Hutto, TX 78634
Mike C.
Job Details: 05/23/2018
Whirlpool Refrigerator WRF990SLAM02 Arrived to install new freezer evaporator defrost harness and control. Checked operation and unit checks good.
Near Driftwood, TX 78619
Diego G.
Job Details: 05/23/2018
Arrived on site. Check for no cooling issues. Found evaporator fan motor seized up and not turning. Replaced evaporator fan motor, all functions tested OK. Instructed customer to allow 24 hours for unit to cool down completely. Job complete
Near Driftwood, TX 78619
Diego G.
Job Details: 05/23/2018
Arrived on site. Check for no cooling issues. Found evaporator fan motor seized up and not turning. Replaced evaporator fan motor, all functions tested OK. Instructed customer to allow 24 hours for unit to cool down completely. Job complete
Near Driftwood, TX 78619
Diego G.
Job Details: 05/23/2018
Arrived on site. Check for no cooling issues. Found evaporator fan motor seized up and not turning. Replaced evaporator fan motor, all functions tested OK. Instructed customer to allow 24 hours for unit to cool down completely. Job complete
Near Georgetown, TX 78633
Mike G.
Job Details: 05/23/2018
ED5VHEXV006, Arrived on site for FREEZER MAKING A STRANGE SOUND PULL DRAWER OUT THERE WERE COILS RED & WATER FILLING AND SIZZLING checked unit and found that the unit was in defrost and unit was draining water and water was dripping onto element witch was making the sizzling sound checked unit for water leaks and no leaks found at time of srv... unit is draining properly and cooling properly unit checked fine at this time....
Near Georgetown, TX 78633
Mike G.
Job Details: 05/23/2018
ED5VHEXV006, Arrived on site for FREEZER MAKING A STRANGE SOUND PULL DRAWER OUT THERE WERE COILS RED & WATER FILLING AND SIZZLING checked unit and found that the unit was in defrost and unit was draining water and water was dripping onto element witch was making the sizzling sound checked unit for water leaks and no leaks found at time of srv... unit is draining properly and cooling properly unit checked fine at this time....
Near Cedar Park, TX 78613
Lou
Job Details: 05/23/2018
arrived on site to inspect washer door not unlocking. Upon inspection, I found that the unit was in flood mode. I placed the unit in diagnostics and error code F3E1 appeared. I unplugged the unit and removed the top of the unit and manually unlocked the unit door. I placed the unit in diagnostic mode again and tested. Unit operated as designed and no error codes at the end of diagnostics. I advised the customer on proper detergent use and advised not to use the detergent pods as they produce too much suds and will cause the unit to go into flood mode as it did this time. I advised the customer that while testing the unit, I found a large amount of soap suds in the basket even though there was no detergent added to the unit before testing. I instructed the customer on the right amount of detergent and softner to use with each load. No water leaks observed during service.
Near Austin, TX 78746
Luis
Job Details: 05/23/2018
Jenair refrigerator-diagnosed unit will need drain pan
Near Austin, TX 78748
Kevin
Job Details: 05/23/2018
Arrived on site and found washer is unplugged, as soon as power is connected drain pump is running. Set unit into diagnostic cycle and pump stops. Ran all functions in diagnostic cycle and everything checks good, incoming water pressure is good and drain pump is strong. Confirmed pressure hose is clear, ran a calibration cycle and function has returned to washer. Started a load on bulky and it is progressing properly. No water leaks from connections at time of service, job complete
Near Austin, TX 78746
Luis
Job Details: 05/23/2018
Near New Braunfels, TX 78132
Connor M.
Job Details: 05/23/2018
KEBC107KSS03 kitchenaid oven Thermal cutoff 72.95 W240-229.99 arrived on site to test unit for not baking after clean cycle. Found failed hi limit cutoff. Will need to replace. Microwave needs to be removed for repair. JA approved 2/29 please send cm only. Customer needs before noon.
Near Spicewood, TX 78669
Thomas L.
Job Details: 05/23/2018
Removed and replaced icemaker due to stalled motor, open heater, and inaccurate ui and control . Water connections were all dry.
Near Fort Hood, TX 76544
Dona
Job Details: 05/23/2018
Arrived on site for unit taking long dry times, found no air flow still at time of service. Removed duct work on wall and have airflow. Showed customer airflow with ducting and without airflow with ducting on. Will need to have ducting cleared or shortened. All parms check good on dryer.
Near Pflugerville, TX 78660
Nathaniel B.
Job Details: 05/23/2018
Model GS773LXSS0, Arrived on call for right front burner will not light, found right front burner igniter sometimes not lighting right away, found electrode for right front burner igniter loose will replace electrode first to verify if spark module and switches harness are needed or not , Skyped office parts and talked to jordan and will reschedule for 5/28/18
Near Pflugerville, TX 78660
Nathaniel B.
Job Details: 05/23/2018
Model GS773LXSS0, Arrived on call for right front burner will not light, found right front burner igniter sometimes not lighting right away, found electrode for right front burner igniter loose will replace electrode first to verify if spark module and switches harness are needed or not , Skyped office parts and talked to jordan and will reschedule for 5/28/18
Near Austin, TX 78730
Cliff
Job Details: 05/23/2018
Roper washer RTW4516FW2. Arrived on site to diagnose a washing machine that does not exist at least starting cycles. Tested unit and Found Coldwater not coming in every time valve is activated. Found loose wiring connection on cold water solenoid valve. Reconnected valve properly and tested unit. Found all is functioning properly at this time. Recalibrated washer to ensure proper performance. No water leaks were found at the time of service.
Near Copperas Cove, TX 76522
Dona
Job Details: 05/23/2018
Arrived on site for no heat condition, found open tco, replaced verified temperatures cycling correctly. Customer needs to have ducting clean as there is an obstruction preventing airflow. Left ducting off as customer is going to try to clean himself. All parms check correct.
Near Pflugerville, TX 78660
Nathaniel B.
Job Details: 05/23/2018
Model MVWP575GW0, Arrived on call for washer not drawing any hot water and has a lid lock error, replaced temp switch and valve prior and still when set to warm only getting cold water, installed lid lock and control and tested and lid lock checks good know and after replacing control and set to warm unit is know getting warm water but instructed customer on the normal setting will only do cold water that is the way it is programed but all the cycles in blue will no a warm cycle, all checks good, no water leaks after repair, call complete.
Near Pflugerville, TX 78660
Nathaniel B.
Job Details: 05/23/2018
Model MVWP575GW0, Arrived on call for washer not drawing any hot water and has a lid lock error, replaced temp switch and valve prior and still when set to warm only getting cold water, installed lid lock and control and tested and lid lock checks good know and after replacing control and set to warm unit is know getting warm water but instructed customer on the normal setting will only do cold water that is the way it is programed but all the cycles in blue will no a warm cycle, all checks good, no water leaks after repair, call complete.
Near Austin, TX 78717
Lou
Job Details: 05/23/2018
arrived on site to inspect vent hood fan not working. Upon further inspection, I found that when turning the fan switch on the fan motor sounds as if it is working. I removed the vent filter and found that the fan blade had been melted onto the motor. The customer advised that a large flame had gone up to the filter while she was cooking. I advised the customer that the motor assembly would need to be replaced; however, that part is no longer available and she would need to replace the entire vent good unit. I unplugged the fan from the switch and used electrical tape to seal the connections from shorting out as the customer wants to use the vent hood light until she can replace the vent hood. I advised the customer that they would need to keep the filter clean which is the reason the flame caught the unit on fire due to a large amount of grease residue. Job completed. Took two pics of damaged vent hood.
Near San Marcos, TX 78666
Connor M.
Job Details: 05/23/2018
MER7662XQ1 maytag range Arrived on site to tets unit for not coming out of preheat. Found all components checked fine. Sensor ohmed 1024. Replaced control and tested. Unit now baking but not registering temp. Replaced sensor, unit working properly.
Near Canyon Lake, TX 78133
Diego G.
Job Details: 05/23/2018
Arrived on site. Replaced filter heater for icemaker on door. Ran diagnostic test, all functions tested OK. Instructed customer to allow 24 hours for icemaker to fill up ice bin. No leaks present. Job complete
Near Canyon Lake, TX 78133
Diego G.
Job Details: 05/23/2018
Arrived on site. Replaced filter heater for icemaker on door. Ran diagnostic test, all functions tested OK. Instructed customer to allow 24 hours for icemaker to fill up ice bin. No leaks present. Job complete
Near Canyon Lake, TX 78133
Diego G.
Job Details: 05/23/2018
Arrived on site. Replaced filter heater for icemaker on door. Ran diagnostic test, all functions tested OK. Instructed customer to allow 24 hours for icemaker to fill up ice bin. No leaks present. Job complete
Near Georgetown, TX 78633
Mike G.
Job Details: 05/23/2018
KGCU462VSS02, Arrived on site for cooktop SCRATCHED, checked unit and found that the control panel is scratched and will need to be replaced ordering part per CS will only need 1 tech and 1hr to do repair per JA r/s next apt for 5/25/18 but customer is wanting next apt for 5/29/18
Near Georgetown, TX 78633
Mike G.
Job Details: 05/23/2018
KGCU462VSS02, Arrived on site for cooktop SCRATCHED, checked unit and found that the control panel is scratched and will need to be replaced ordering part per CS will only need 1 tech and 1hr to do repair per JA r/s next apt for 5/25/18 but customer is wanting next apt for 5/29/18
Near The Hills, TX 78738
Brandon
Job Details: 05/23/2018
Arrived on site for part hanger, I replaced drain pump, unit tested good water lines were dry at time of service.
Near Meadowlakes, TX 78654
Thomas L.
Job Details: 05/23/2018
Arrived on site for or drying conditions. Tested water to find it at 126 degrees at sink and 94 in unit at first fill. customer to run water at sink 1st. Filled up drying agent. Increase drying agent setting. Customer to have drain hose elevated. All water connections were dry.
Near Austin, TX 78731
Cliff
Job Details: 05/23/2018
Whirlpool dishwasher WDT710PAYM3. Arrived on site to install rack stop for dishwasher. Replaced stop and tested unit. Found all is functioning properly at this time. No leaks were found at time of service.
Near Austin, TX 78717
Lou
Job Details: 05/23/2018
arrived on site to inspect dishwasher not drying. Open further inspection, I placed the unit in diagnostics and tested. Unit operated as designed. I explained to the customer that due to the unit having a plastic tube, the plastic is going to absorb the heat and will not dry like a unit with a stainless steel tub where the heat will retract and dry the dishes much better. Customer advised that she does not like the unit and will work with her builder to replace the unit. No water leaks observed during service.
Near Kyle, TX 78640
Kevin
Job Details: 05/23/2018
Arrived on site and started dryer on a normal cycle and found a grinding noise during operation. Found metal debris stuck in the felt ring that is making noise. After clearing noise has stopped, no lift found in unit cabinet at time of service, job complete.
Near Temple, TX 76504
Dona
Job Details: 05/23/2018
Arrived on site for high temps in refrigerator, found 4 inch ice build up on evaporator, customer started defrost process tech completed defrost. Replaced rc therm and control. Verified operations, unit temps are dropping and door is sending signal when open. All water connections dry.
Near Georgetown, TX 78633
Mike G.
Job Details: 05/23/2018
KMHS120ESS5, Arrived on site for unit say open and close door checked unit and found that the door switches are bad replaced all 3 door switches and checked unit and unit is working properly unit checked fine at this time....
Near Georgetown, TX 78633
Mike G.
Job Details: 05/23/2018
KMHS120ESS5, Arrived on site for unit say open and close door checked unit and found that the door switches are bad replaced all 3 door switches and checked unit and unit is working properly unit checked fine at this time....
Near San Marcos, TX 78666
Connor M.
Job Details: 05/23/2018
WRS571CIDM01 whirlpool refrigerator Arrived on site to install paets for repair. Installed ice bin and ice door. Unit working properly, no leaks detected. If issue persists freezer door will be needed.
Near Pflugerville, TX 78660
Jonathan S
Job Details: 05/23/2018
Whirlpool refrigerator model# WRX735SDBM02. Not making ice. Ice maker making loud noises. Water disp
Near Austin, TX 78703
Luis
Job Details: 05/23/2018
Icemachine. Replaced ice cutter grid assembly
Near Marble Falls, TX 78654
Thomas L.
Job Details: 05/23/2018
Arrived on site for no ice dispensing condition. Found motor turning shaft but not auger. Auger in bin ice cracked. Replaced bin. All water connections were dry.
Near Kyle, TX 78640
Kevin
Job Details: 05/23/2018
Home is on a new Street, took one picture of location on map. Arrived on site and inspected refrigerator and found freezer door is closing properly, soft clothes only works on the last 3 inches of movement. Middle drawer in freezer is broken and front will not stay on. Will need to bring back a new drawer to correct issue. No water leaks from connections at time of service.
Near Harker Heights, TX 76548
Dona
Job Details: 05/22/2018
Arrived on site for unit not advancing, unit is full of water, lid switch checks good. Unit would not fill at all was not sending voltage to motor. timer motor not advancing, customer stated that only part of timer has been working for a while. Next tech replaced timer, unit would then fill but not advance cycles, found bad pressure switch and intermittent lid switch. Replaced pressure switch, and lid switch. Unit is filling, stopping fill on correct water level. Checked water shut off on load size 6 times to verify no overflow. Unit agitating, spinning and draining. All water connections dry.
Near Harker Heights, TX 76548
Dona
Job Details: 05/22/2018
Arrived on site for unit not advancing, unit is full of water, lid switch checks good. Unit would not fill at all was not sending voltage to motor. timer motor not advancing, customer stated that only part of timer has been working for a while. Next tech replaced timer, unit would then fill but not advance cycles, found bad pressure switch and intermittent lid switch. Replaced pressure switch, and lid switch. Unit is filling, stopping fill on correct water level. Checked water shut off on load size 6 times to verify no overflow. Unit agitating, spinning and draining. All water connections dry.
Near Liberty Hill, TX 78642
Lou
Job Details: 05/22/2018
arrived on site to install previously diagnosed and ordered parts. Removed and replaced the door, door gasket with high temp adhesive, and the water valve and hose. Tested unit and unit tested good. No water leaks observed during service.
Near Harker Heights, TX 76548
Dona
Job Details: 05/22/2018
Arrived on site for unit stopped mid cycle, no operation, found open fuse and burned connector on control. Replaced main control and open fuse. Verified operations all check good. All water connections dry.
Near Pflugerville, TX 78660
Joseph C.
Job Details: 05/22/2018
KDTM354DSS5 Arrived on site for “broken dispenser door” complaint. Inspected unit and found broken dispenser door. Removed and replaced dispenser. Tested unit. Unit is performing as designed. No leaks detected, at time of service.
Near Hays, TX 78610
Kevin
Job Details: 05/22/2018
Arrived on site and found all LEDs including freezer are not coming on when doors are open. Reset all connections on LED power supply board and lights are working again. LED power supply board will need to be replaced in order to correct issue.
Near Killeen, TX 76542
Dona
Job Details: 05/22/2018
Arrived on site for unit not always heating, found unit is heating on timed dry but not on energy preferrred. Will need to replace timer and thermostat. Will bring element should not be needed as unit is heating. Dry vent cleared. Jordan assisted with reschedule and parts.
Near Liberty Hill, TX 78642
Lou
Job Details: 05/22/2018
arrived on site to install previously diagnosed and ordered parts. Removed and replaced the glass cooktop. Tested unit and unit operated as designed. Job completed.
Near Austin, TX 78741
Connor M.
Job Details: 05/22/2018
NED4655EW1 Amana dryer Arrived on site to test unit for dryer not heating. Found improper voltage coming to terminal block. Instruct in contacting an electrician. Made aware of proper venting and fire hazard.
Near Killeen, TX 76549
Dona
Job Details: 05/22/2018
Arrived on site for unit not fully draining, found drain level is correct on machine, seals are below water line to keep wet, verified unit draining in cycle, and at end of cycle. Line to garbage disposal is clear water ran freely. All water connections dry. Unit is running to spec. Explained water level to customer.
Near Killeen, TX 76549
Dona
Job Details: 05/22/2018
Arrived on site for no functionality, found control is dead. No lights voltage to board checks correctly. Replaced main control. Verified operations, calibrated, unit filled, agitates, drains and spins. All water connections dry all parms check correct.
Near Liberty Hill, TX 78642
Lou
Job Details: 05/22/2018
arrived on site to inspect cooktop Ignitor constantly clicking. Upon further inspection, I found that the left rear burner valve is sticking causing it to constantly click or attempt to ignite. Also found that the right rear burner flame was only burning on the right side and barely flaming out on the left side of the burner. Office to order left rear valve and right rear burner head/orifice holder and schedule return service for 05/29/18 CS. No gas leaks detected during service.
Near Austin, TX 78735
Kevin
Job Details: 05/22/2018
Arrived on site and replaced flowmeter diagnosed on previous visit, ran a diagnostic cycle and leaking has stopped. Also no water leaks from connections at time of service, job complete
Near Austin, TX 78741
Connor M.
Job Details: 05/22/2018
WRS571CIDM02 whirlpool refrigerator Arrived on site to test unit for making loud noise when opening and closing door. Found diffuser operating loudly. Replaced and tested unit. Unit working properly, no leaks detected.
Near Austin, TX 78745
Connor M.
Job Details: 05/22/2018
WTW5000DW whirlpool washer Arrived on site to test unit for not completeing cycle. Found error code for failed thermistor. Replaced valve and tested unit. Unit working properly, no leaks detected.
Near Austin, TX 78746
Kevin
Job Details: 05/22/2018
Arrived on site and found all LEDs in fresh food and freezer section are not operating. After replacing they will now turn on properly. No water leaks from connections at time of service, job complete.
Near Austin, TX 78733
Kevin
Job Details: 05/22/2018
Arrived on site and found front left and right burners do not ignite consistently. Right burner only needed electrode adjustment as it was not sparking consistently in one direction. Bending it closer to burn her head correct it’s operation. Left front electrode had failed and after replacing it is now working properly. Quoted the customer for one electrode and remaining labor to replace it. Job complete.
Near Austin, TX 78717
Lou
Job Details: 05/22/2018
arrived on site to inspect dishwasher dispenser not closing. Upon further inspection, I found that the latch on the dispenser was broken. I removed and replaced the dispenser and placed the unit in diagnostics. Unit operated as designed. No water leaks observed during service.
Near Austin, TX 78717
Lou
Job Details: 05/22/2018
Arrived on site to inspect oven door handle loose. Upon further inspection, I found that the vent trim was badly damaged and missing two screws. Where the handle screws into the vent trim was broken off and the the that attaches the handle to the vent trim and the screw test attaches the handle/vent trim to the door were missing. Also, the handle was badly damaged, as well. I removed and replaced the vent trim and handle and returned the door to the oven unit. Unit operated as designed.
Near Spicewood, TX 78669
Cliff
Job Details: 05/22/2018
Maytag washer MVWC416FW0. Arrived on site to diagnose a washing machine with an agitator that is coming off of driveshaft. Tested unit and found wash plate and barrel sections of agitator both damaged due to loose bolt. Also bolt does not appear to of had any Loctite from manufacturing to prevent loosening of the bolt over time. Replaced Washplate, bolt and barrel and tested unit. Found all is functioning properly at this time. No leaks were found at time of service.
Near Robinson, TX 76706
Mike G.
Job Details: 05/22/2018
Arrived on site for CLOTHING STUCK UNDER AGITATOR, checked unit and found that the agitator is warped removed clothing and replaced agitator and checked unit and unit checked fine at this time... , MVWB765FW0
Near Robinson, TX 76706
Mike G.
Job Details: 05/22/2018
Arrived on site for CLOTHING STUCK UNDER AGITATOR, checked unit and found that the agitator is warped removed clothing and replaced agitator and checked unit and unit checked fine at this time... , MVWB765FW0
Near Austin, TX 78739
Connor M.
Job Details: 05/22/2018
GS6NBEXRS01 whirlpool refrigerator Arrived on site to test unit for leaking. Found coupling at bottom fo door loose, water line not seated correctly. Corrected issue and tested unit. Unit working properly, no leaks detected.
Near Manor, TX 78653
Joseph C.
Job Details: 05/22/2018
WRS325FDAM04 Arrived on site for “shoots ice out of dispenser” complaint. Inspected unit and found dispenser door closing too soon. Adjusted closer. Tested unit. Unit is performing as designed. No leaks detected, at time of service.
Near Manor, TX 78653
Joseph C.
Job Details: 05/22/2018
WMH32519FS1 Arrived on site for “door open error” complaint. Inspected unit and found door switches and interlocks faulty. Removed and replaced door switches and interlocks. Unit tests good.
Near Briarcliff, TX 78669
Cliff
Job Details: 05/22/2018
Kitchenaid refrigerator KRFC302EPA00. Arrived on site to diagnose a refrigerator with a door that is not closing properly. Tested unit and found due to the heavy custom paneling door has dropped over time. Adjusted hinges and tested unit. Found all is functioning properly at this time. No leaks were found at time of service.
Near New Braunfels, TX 78130
Diego G.
Job Details: 05/22/2018
Arrived on site. Check for icemaker issues. Found module bad on ice maker. Replaced ice maker and cycled, all functions tested OK. No leaks present. Job complete
Near New Braunfels, TX 78130
Diego G.
Job Details: 05/22/2018
Arrived on site. Check for icemaker issues. Found module bad on ice maker. Replaced ice maker and cycled, all functions tested OK. No leaks present. Job complete
Near New Braunfels, TX 78130
Diego G.
Job Details: 05/22/2018
Arrived on site. Check for icemaker issues. Found module bad on ice maker. Replaced ice maker and cycled, all functions tested OK. No leaks present. Job complete
Near Bee Cave, TX 78738
Brandon
Job Details: 05/22/2018
Arrived on site for frost build up in freezer section, found frame of unit needed sealant around freezer section to make a better seal. I used sealant from truck stock to seal the unit, tested good. Water lines were dry at time of service.
Near Austin, TX 78745
Connor M.
Job Details: 05/22/2018
MEDC215EW1 maytag dryer Installed timer, squeak coming from idler pulley. Added a drop of lube and ran for twenty mins no squeak. Unit working properly. Instruct on proper venting.
Near Harker Heights, TX 76548
Dona
Job Details: 05/22/2018
Arrived on site for no operation and error, previous tech installed control that was faulty. Found open thermal fuse upon return. Replaced thermal fuse wp3392519 used from 187201 Kristen and sarah assisted. Verified operations and temperatures. Airflow seems good, instructed customer to have duct work checked throughout the year. Ducting clear. All parms check good.
Near Lorena, TX 76655
Mike G.
Job Details: 05/22/2018
WTW8500DC4, Arrived on site for unit not cleaning, checked unit in test cycle and unit ran all test with no issues Recalibrated unit and ran unit with load of towels and unit filled washed and drained and rinsed and is spining and lid is locking and unlocking checked unit for water leaks and no leaks found at time of srv.... unit checked fine at this time......
Near Lorena, TX 76655
Mike G.
Job Details: 05/22/2018
WTW8500DC4, Arrived on site for unit not cleaning, checked unit in test cycle and unit ran all test with no issues Recalibrated unit and ran unit with load of towels and unit filled washed and drained and rinsed and is spining and lid is locking and unlocking checked unit for water leaks and no leaks found at time of srv.... unit checked fine at this time......
Near Austin, TX 78748
Connor M.
Job Details: 05/22/2018
WED5000DW whirlpool dryer Arrived on site to test unit for no heat. Found element cycling properly with door open. Found about 6 feet of duct crushed into about 4 inches causing poor air flow. Instruct customer on replaceing and or shortneing dryer duct. Made aware of proper veting and fire hazard.
Near Austin, TX 78734
Brandon
Job Details: 05/22/2018
Arrived on site for loud humming noise, found sump to be faulty, I replaced sump, unit tested good. Water lines were dry at the time of service.
Near Cedar Park, TX 78613
Lou
Job Details: 05/22/2018
arrived on site to inspect dishwasher dispenser not opening. Upon further inspection, I found that the units dispenser components are plastic and due to their age they are worn and are not functioning properly. I tested the unit by taking the inner door liner off and verifying the connection between the cam and the actuator but the teeth on the actuator are worn as are on the cam. The door latch is worn as well. Office to order latch kit, actuator, dispenser, draw bar, spring, dispenser door, door spring, pin dowel, drip cover, and follower/cam. Office to schedule return service. No water leaks observed during service.
Near Killeen, TX 76542
Dona
Job Details: 05/22/2018
Arrived on site for noise in spin, found nut to pulley on gearcase loose, allowing for noise between shift actuator change and spin. Retightened, verified operations. No errors, all water connections dry all parms check correctly. No noise.
Near Austin, TX 78746
Kevin
Job Details: 05/22/2018
Arrived on site and found drain the motor is not moving water, inspected drain and found a piece of glass stopping impeller from spinning. Took one picture. Impeller is damaged and drain pump will need to be replaced. After replacing pump ran a diagnostic cycle and confirmed all operations are correct. Also found drain connection to garbage disposal is shared with reverse osmosis system. This should not be done because reverse osmosis purging could overflow dishwasher. Recommend that customer contact reverse osmosis company to correct this. Drain motor $81.02 DW165 $169.99
Near Austin, TX 78725
Joseph C.
Job Details: 05/22/2018
AMV2307PFS0 Arrived on site for “noisy fan operation” complaint. Inspected unit and found loose construction debris in fan housing. Removed debris and tested fan. Unit is performing as designed.