Near Spicewood, TX 78669
Cliff
Job Details: 07/25/2017
Kitchenaid dishwasher KDTE254ESS2. Arrived on site to diagnose a dishwasher that will not close properly. Found dishwasher was not leveled during installation and this was causing the door not to be in line with the tub. Leveled unit properly and tested unit. Found all is functioning properly at this time. No water leaks were found at time of service.
Near Austin, TX 78704
Luis
Job Details: 07/25/2017
Refrigerator-KRSC503ESS00-Installed new ice chute and coupling reassembled unit. Tested ice dispenser unit working correctly.
Near Austin, TX 78704
Luis
Job Details: 07/25/2017
Wine cooler-KUWL204ESB00-loud noise readjusted condenser coil housing.
Near Fischer, TX 78623
Daniel A.
Job Details: 07/25/2017
WRX735SDBM03 Freezer door not closing/sealing properly. Replaced freezer door rails. Cleaned freezer bottom interior. Verified normal door closure/seal after repair
Near Austin, TX 78738
Thomas L.
Job Details: 07/25/2017
Whirlpool dishwasher model WDF540PADM2. Arrived on site for no operation. Found no power to unit. Reset power supply and tested unit. All operations were normal. All water connections were dry.
Near Bee Cave, TX 78738
Thomas L.
Job Details: 07/25/2017
Near Austin, TX 78731
Luis
Job Details: 07/25/2017
Refrigerator-MFX2570AEM4-no ice, replaced main control ran icemaker through a cycle icemaker working correctly
Near Canyon Lake, TX 78132
Daniel A.
Job Details: 07/25/2017
KRMF606ESS01 Top drawer in freezer handle trim defective. (Unable to repair). Replaced top drawer / bin. Verified normal operation after service. Instruct cust on filter replacement.
Near Leander, TX 78641
Jonathan S
Job Details: 07/25/2017
Oven model# WOS51EC0AS02. No power
Near Georgetown, TX 78633
Mike C.
Job Details: 07/25/2017
Kitchen Aid dishwasher KDTE104ESS1 Arrived to install new sump and motor. Checked operation and unit checks good. Checked unit for any leaks and none were found.
Near Leander, TX 78641
Jerry C.
Job Details: 07/24/2017
WFG540H0ES0 Arrived to inspect broiler not igniting. I found the igniter lead incorrectly routed and grounding to the chassis. I corrected the wiring issue and tested the unit multiple times, without no fail. Operational test good, no gas leaks detected during service.
Near Dripping Springs, TX 78620
Luis
Job Details: 07/24/2017
Refrigerator-WRS325FDAM04-middle of cabinet extremely hot,found damaged air baffle assembly,replaced air baffle assembly tested working correctly
Near Spicewood, TX 78669
Cliff
Job Details: 07/24/2017
Kitchenaid range KSGG700ESS0. Arrived on site to replace regulator for range. Replaced regulator and tested unit. Found all is functioning properly at this time. No gas leaks were found at time of service.
Near Spicewood, TX 78669
Cliff
Job Details: 07/24/2017
Kitchenaid range KSGG700ESS0
Near Austin, TX 78745
Luis
Job Details: 07/24/2017
Refrigerator-KRMF706ESS00-no ice. E2 error. Replaced icemaker ran test icemaker working
Near Cedar Park, TX 78613
Jerry C.
Job Details: 07/24/2017
WRF989SDAM00 Arrived to inspect no cool. I found the rc at 45 and the fc at 39. There was barely any frost on either evaporator and the condenser was room temperature. The discharge tube was hot, but cool before the condenser and the compressor was very hot. The unit had a silver rc evap W10917531 and I removed it and the compressor W10276644 and replaced them. I pulled vacuum for 15 min and then monitored for an additional 15. The unit held vacuum and I charged it with 5.5 oz per the mfg. the compressor was quite noisy initially, but did quiet after a few minutes. I advised the customer to contact us if the noise comes back. Operational test good, no leaks observed during service.
Near Austin, TX 78738
Cliff
Job Details: 07/24/2017
Jennair refrigerator JS42SEDBDA. Arrived on site to diagnose a refrigerator that is not cooling properly. Tested unit and found freezer evaporator fan blade has come off of fan motor. Remounted fan blade and tested unit. Found all is functioning properly at this time. No water leaks were found at time of service.
Near Cedar Park, TX 78613
Jerry C.
Job Details: 07/24/2017
MDB8969SDM0 Arrived to inspect continuing debris in wash. I found the customer had been following prior detergent and use recommendations, but there was too much debris within the sump assembly WPW10591570. I found large amounts within the sump and removed and replaced it. I verified correct operation and no leaks.
Near Horseshoe Bay, TX 78657
Thomas L.
Job Details: 07/24/2017
Arrived on site for over ice production.. I found that the ice bin thermistor was out of range. Removed and replaced. Water connections were dry. Model KUIC15PHZS. Serial k50716883
Near Round Rock, TX 78681
Jerry C.
Job Details: 07/24/2017
KUIC15PHZS0 Arrived to instal previously diagnosed and ordered part. I flushed the water supply to the unit and removed the existing valve. I installed the replacement water valve W10881366 and tested the unit. All functions were present in service test mode and the unit began production within normal mode. Operational test good, no leaks observed during service.
Near New Braunfels, TX 78130
Daniel A.
Job Details: 07/21/2017
WRV986FDEM00 Refrigerator not cooling / ran diagnostic. Test 39 for RC thermistor 02 for open thermistor. Replaced RC thermistor. Verified normal operation after service. Ran test. 01 for pass. Verified with tech assist.
Near Lakeway, TX 78738
Jerry C.
Job Details: 07/21/2017
KDTE104ESS0 Arrived to inspect unit not draining. I found the drain pump would on,y hum and not rotate and pump out the water. I removed the pump and found glass within the pump housing and removed it. I replaced the pump WPW10348269 due to a strong acrid odor and tested the unit. Operational test good, no leaks observed during service. The old style filter is in this unit and office to D2C p/n W10872845 filter.
Near Lakeway, TX 78738
Jerry C.
Job Details: 07/21/2017
KDTE104ESS0 Arrived to inspect unit not draining. I found the drain pump would on,y hum and not rotate and pump out the water. I removed the pump and found glass within the pump housing and removed it. I replaced the pump WPW10348269 due to a strong acrid odor and tested the unit. Operational test good, no leaks observed during service. The old style filter is in this unit and office to D2C p/n W10872845 filter.
Near Austin, TX 78748
Luis
Job Details: 07/21/2017
Refrigerator-WRS571CIDM02-Tested dispenser found auger motor shaft spring not inserted into coupling correctly. Removed shaft assembly,installed spring correctly to coupling
Near Dripping Springs, TX 78620
Jerry C.
Job Details: 07/21/2017
WFG530S0ES1 Arrived to inspect cooktop damage. I found a large dent at the from of the cooktop. I removed and replaced the cooktop and installed the replacement improved grates. I tested the unit and it operated as designed. Operational t at good, no gas leaks detected during service.
Near Georgetown, TX 78628
Mike C.
Job Details: 07/21/2017
Whirlpool Range WFG510S0AS2 Arrived to install new bake ignitor, ignitor harness, spark module and gas valve. Checked operation and unit checks good.
Near Austin, TX 78759
Luis
Job Details: 07/21/2017
Refrigerator-WRX735SDBM03-unit leaking and not cooling. Replaced main control board
Near Dripping Springs, TX 78620
Jerry C.
Job Details: 07/21/2017
WDF540PADM2 Arrived to inspect unit not turning on. I found the pigtail was plugged into a new style child safety outlet and was not correctly engaged. I corrected the issue and tested the unit. I discussed the importance of purging cold from the hot water supply prior to use, the proper amount of detergent and the use of rinse agent. Operational test good, no leaks observed during service.
Near Austin, TX 78759
Luis
Job Details: 07/21/2017
Refrigerator-KFIV29PCMS03-no cool. Defrosted evaporator,replaced thermistor harness
Near Dripping Springs, TX 78620
Jerry C.
Job Details: 07/21/2017
MEDB880BW0 Arrived to inspect no heat. The unit would run, but not heat. I found the element had failed and there was an excessive amount of debris within the unit. I removed the debris and replaced the element WP8544771 and tested. The unit heated and cycled as designed, but internal temperatures suggest a restricted venting system and I advised the customer to have it professionally cleaned. Operational test ok, lint removed from chassis and no leaks observed during service.
Near Dripping Springs, TX 78620
Jerry C.
Job Details: 07/21/2017
MEDB880BW0 Arrived to inspect no heat. The unit would run, but not heat. I found the element had failed and there was an excessive amount of debris within the unit. I removed the debris and replaced the element WP8544771 and tested. The unit heated and cycled as designed, but internal temperatures suggest a restricted venting system and I advised the customer to have it professionally cleaned. Operational test ok, lint removed from chassis and no leaks observed during service.
Near Austin, TX 78736
Connor M.
Job Details: 07/21/2017
Maytag washer Arrived onsite to test unit for not spinning clothes out. Found pillow case between tub and basket. Removed and tested unit. No leaks dteteced.
Near Austin, TX 78717
Cliff
Job Details: 07/21/2017
Whirlpool dishwasher WDT720PADM2. Arrived on site today and I was a dishwasher that is not drying properly. Tested unit and could find no failures or error codes through diagnostics. Advised homeowner on proper water temperature requirements and options to use for optimal performance. No other repairs needed at this time. No water leaks were found at time of service.
Near Dripping Springs, TX 78620
Jerry C.
Job Details: 07/21/2017
KUDI02FRSS0 Arrived to instal previously diagnosed and ordered parts. I removed and replaced the failed door closer assemblies 8194001 and tested. I removed and replaced the thermal fuse W10258275 per mfg instructions and tested. Operational test good, no leaks observed during service.
Near Georgetown, TX 78628
Thomas L.
Job Details: 07/21/2017
Arrived on site for no drain/failure code condition. Found that the drain pump motor was defective. Removed and replaced and tested. Water connections were all dry. Maytag front load washer. Won't drain. Model mhwz600tb02
Near Leander, TX 78641
Cliff
Job Details: 07/21/2017
Whirlpool washer WTW7000DW0. Arrived on site to diagnose a washing machine that is not completing cycles. Tested unit through diagnostics and found F0E5 out of balance error code. No other failures or found to unit, through automatic or manual diagnostics. Calibrated unit to ensure machine was registering proper load sizes. Advised homeowner on best loading procedures and load sizes for optimal wash performance. Also advised homeowner if machine fails to balance the load it will failed to complete the cycle and may not drain properly. No leaks were found at time of service.
Near Georgetown, TX 78628
Mike C.
Job Details: 07/21/2017
Whirlpool Refrigerator wrf535smbm00 Arrived to check unit for ice maker leaking and a tear in the right fresh food door gasket. Found ice maker not leveled and the water is running towards the front of the ice maker and leaking out into the ice bin. Leveled ice maker and tightened mounting screws. Found the top of the right door gasket is tearing. Replaced door gasket. Checked operation and unit checks good. Checked unit for any leaks and none were found.
Near Georgetown, TX 78628
Mike C.
Job Details: 07/21/2017
Near Salado, TX 76571
Mike G.
Job Details: 07/21/2017
WTW7300DW1, Arrived on site for WASH PLATE ONLY MOVES AN INCH//TOP CLOTHES AREN'T GETTING PULLED DOWN IN WATER//SAME ON ALL CYCLES, checked unit and found that the unit needs to be recalibrated, recalibrated unit and ran test on unit and ran all test fine, checked unit for water leaks and no leaks found at time of srv... Unit checked fine at this time.....
Near Salado, TX 76571
Mike G.
Job Details: 07/21/2017
WTW7300DW1, Arrived on site for WASH PLATE ONLY MOVES AN INCH//TOP CLOTHES AREN'T GETTING PULLED DOWN IN WATER//SAME ON ALL CYCLES, checked unit and found that the unit needs to be recalibrated, recalibrated unit and ran test on unit and ran all test fine, checked unit for water leaks and no leaks found at time of srv... Unit checked fine at this time.....
Near Austin, TX 78717
Jonathan S
Job Details: 07/21/2017
Whirlpool oven WGG555S0BS01. Failed UI.
Near Cedar Park, TX 78613
Jerry C.
Job Details: 07/20/2017
WDF320PADS3 Arrived to inspect dishwasher not filling. I found the valve tested at 1.4K ohm, but only 23VAC from the control. I removed and replaced the control W10906425 and tested the unit in service test mode. Operational test good, no leaks observed during service.
Near Austin, TX 78749
Connor M.
Job Details: 07/20/2017
MEDB835DW maytag dryer Arrived on site to test unit for not working intermittently. Found f4e3 saved several times representing poor air flow. Found 8 feet worth of soft flex duct installed. This is not recommended by whirlpool due to the ridges that form when duct is not fully extended. Instruct customer on replacing duct with rigid duct. Made the, aware of proper venting and fire hazard,
Near Austin, TX 78735
Connor M.
Job Details: 07/20/2017
WRS331FDDM01 whirlpool refrigerator
Near Spicewood, TX 78669
Cliff
Job Details: 07/20/2017
Jennair range JGS8860BDP17. Arrived on site to replace control panel, knob, and bake igniter for oven. Replaced all three parts and tested unit. Found all is functioning properly at this time. No gas leaks were found at time of service.
Near Temple, TX 76502
Mike G.
Job Details: 07/20/2017
WRF736SDAM13, Arrived on site for unit not making ice, when arrived on site customer stating that unit is making ice but not disp ice checked unit and found that the ice is jamed in the ice ben removed ice ben and unjamed ice from ice ben reinstalled ice ben and checked unit and unit is now disp ice checked unit for water leaks and no leaks found at time of srv.....
Near Temple, TX 76502
Mike G.
Job Details: 07/20/2017
WRF736SDAM13, Arrived on site for unit not making ice, when arrived on site customer stating that unit is making ice but not disp ice checked unit and found that the ice is jamed in the ice ben removed ice ben and unjamed ice from ice ben reinstalled ice ben and checked unit and unit is now disp ice checked unit for water leaks and no leaks found at time of srv.....
Near Austin, TX 78739
Connor M.
Job Details: 07/20/2017
WFG540H0ES whirlpool range Arrived on site to test unit for connect fan not powering on. Found harness not connected to fan in rear of unit. Corrected issue and tested. Unit working properly. Fan only powers on 5 mins after start time no matter what. Fan shuts off immediately when door is open. Job completed.
Near Austin, TX 78734
Cliff
Job Details: 07/20/2017
Maytag refrigerator MFI2665XEM7. Arrived on site to replace icemaker for refrigerator. Replaced ice maker and tested unit. Found all is functioning properly at this time. No water leaks were found at time of service.
Near Cedar Park, TX 78613
Jerry C.
Job Details: 07/20/2017
KDTE204ESS2 arrived to inspect not washing. 7-1 code stored stored in memory. I found the sump motor would not engage and I verified 121VAC to the motor. During testing I found errant voltage of 20-35 VAC to the pump. I removed and replaced the control W10854225 and sump assembly WPW10605058 and tested the unit. I advised the customer to use approximately one tablespoon of liquid detergent since they pre-rinse. I discussed the importance of purging the cold from the hot water supply prior to use. I set dispenser to setting 2 and advised the customer of rinse agent types and amounts. Operational test good, no leaks observed during service.
Near Austin, TX 78746
Luis
Job Details: 07/20/2017
Ice machine-KUIX505ESS0-filter unable to be removed. Replaced water filter housing
Near Temple, TX 76504
Mike G.
Job Details: 07/20/2017
RED4516FW0, Arrived on site for Dryer start button popped off. Can not start unit, checked unit and found that the stat switch has poped out of place reinstalled start switch checked and cleaned out all lent found from unit checked unit after repair and unit is now stating and heating unit checked fine at this time....
Near Temple, TX 76504
Mike G.
Job Details: 07/20/2017
RED4516FW0, Arrived on site for Dryer start button popped off. Can not start unit, checked unit and found that the stat switch has poped out of place reinstalled start switch checked and cleaned out all lent found from unit checked unit after repair and unit is now stating and heating unit checked fine at this time....
Near Kyle, TX 78640
Diego G.
Job Details: 07/20/2017
Arrived on site. Check for heating issues. Found no error codes. Ran diagnostic test all functions tested OK. Instructed customer to use rinse aid to help improve drying. No leaks present. Job complete.
Near Kyle, TX 78640
Diego G.
Job Details: 07/20/2017
Arrived on site. Check for heating issues. Found no error codes. Ran diagnostic test all functions tested OK. Instructed customer to use rinse aid to help improve drying. No leaks present. Job complete.
Near Kyle, TX 78640
Diego G.
Job Details: 07/20/2017
Arrived on site. Check for heating issues. Found no error codes. Ran diagnostic test all functions tested OK. Instructed customer to use rinse aid to help improve drying. No leaks present. Job complete.
Near Kyle, TX 78640
Diego G.
Job Details: 07/20/2017
Arrived on site. Check for heating issues. Found no error codes. Ran diagnostic test all functions tested OK. Instructed customer to use rinse aid to help improve drying. No leaks present. Job complete.
Near Kyle, TX 78640
Diego G.
Job Details: 07/20/2017
Arrived on site. Check for heating issues. Found no error codes. Ran diagnostic test all functions tested OK. Instructed customer to use rinse aid to help improve drying. No leaks present. Job complete.
Near Kyle, TX 78640
Diego G.
Job Details: 07/20/2017
Arrived on site. Check for heating issues. Found no error codes. Ran diagnostic test all functions tested OK. Instructed customer to use rinse aid to help improve drying. No leaks present. Job complete.
Near Austin, TX 78741
Luis
Job Details: 07/20/2017
Refrigerator-KRFC704FPS00-door. It opening. Replaced closer and bushing
Near Austin, TX 78737
Connor M.
Job Details: 07/20/2017
MZF34X20DW00 maytag freezer Arrived on site to install parts for repair. Installed compressor valve and drier. Ran deep vacuum, no leaks present. Unit cooling properly. No leaks dteteced.
Near Round Rock, TX 78664
Jonathan S
Job Details: 07/20/2017
Refrigerator model# WRF535SMBM00. Not making ice.
Near Leander, TX 78645
Jerry C.
Job Details: 07/20/2017
JFC2290VEM8 Arrived to instal previously diagnosed and ordered parts. I removed and replaced the mullion WPW10153704 and noted a more positively closing door, with less noise. I removed the gasket W10443241 from the box and re-formed it with a heating gun. I removed the existing torn gasket and replaced it. I verified correct fit and a positive seal. Operational test good, no leaks observed during service.
Near Temple, TX 76502
Mike G.
Job Details: 07/20/2017
KUIC15PHZS0, Arrived on site for clean light stays on and customer is stating that when Clean cycle is started unit start and will shut off after 20 mins and when normal cycle is started the clean light will stay on checked unit and found that unit falls under sp# 10747218 and will need new water level sensor, replaced water level sensor and rechecked unit and unit has and for 35mins and s still on and cleaning checked unit for water leaks and no leaks found at time of srv.... Unit checked fine at this time......
Near Temple, TX 76502
Mike G.
Job Details: 07/20/2017
KUIC15PHZS0, Arrived on site for clean light stays on and customer is stating that when Clean cycle is started unit start and will shut off after 20 mins and when normal cycle is started the clean light will stay on checked unit and found that unit falls under sp# 10747218 and will need new water level sensor, replaced water level sensor and rechecked unit and unit has and for 35mins and s still on and cleaning checked unit for water leaks and no leaks found at time of srv.... Unit checked fine at this time......
Near New Braunfels, TX 78130
Kevin
Job Details: 07/20/2017
Roper washing machine RTW4516FW1, Arrived on site, and found debris inside of tub causing noise during spin, after removing debris and noise has stopped. No saved error codes in diagnostic cycle, all functions are operating correctly. No water leaks from connections at time of service, job complete.
Near Austin, TX 78734
Jerry C.
Job Details: 07/19/2017
MEDB800VQ0 Arrived to instal previously diagnosed and ordered parts. I found the harness was not damaged but was required due to the moisture sensor, which tested correctly in service test mode after replacement. All of the thermal fuses and sensors tested good and I was able to remove all of the lint that had been burned prior. I tested the unit and found it heated and cycled correctly. I advised the customer to have the vents cleaned prior to use of the unit, due to the amount of lint found within the chassis. Operational test good, lint removed from cabinet and no leaks observed during service.
Near Dripping Springs, TX 78620
Connor M.
Job Details: 07/19/2017
WRX735SDBM04 whirlpool refrigerator Arrived on site to test unit for no ice. Found fill tube chute filled with ice. Removed and tested unit unit working properly. No leaks detected.
Near Austin, TX 78738
Cliff
Job Details: 07/19/2017
Whirlpool dryer WED4815EW1. Arrived on site to diagnose a dryer that has long dry times. Tested unit and found no mechanical failures to heating system or dryer. Tested external venting and found it is clogged and causing the dryer to overheat and shut the heating system down. Advised homeowner external vent should be cleaned regularly to prevent housefires and improve drying performance.
Near Austin, TX 78732
Jerry C.
Job Details: 07/19/2017
JS48SEDBDA Arrived to instal previously diagnosed and ordered part. I removed the failed auger drive motor after verifying failure. I replaced the motor assembly 12001773 and tested. Operational test good, no leaks observed during service.
Near Austin, TX 78703
Luis
Job Details: 07/19/2017
Refrigerator-WRF535SMBM00-replaced freezer door gasket
Near Georgetown, TX 78633
Mike C.
Job Details: 07/19/2017
Whirlpool Oven WOD51EC0AS01 Arrived to find control panel blank and unresponsive and lower door locked. Found thermal fuse open. Installed new thermal fuse and checked operation, unit checks good. Fuse $28.40 - WO380 $159.99
Near Marble Falls, TX 78654
Thomas L.
Job Details: 07/19/2017
Arrived on site for new operation. Found power to control but no power out of control. Also found light cycle button on the control panel is defective. Replaced control and panel. Unit now operates properly with no leaks. Maytag dishwasher model number MDB6650WB and serial number 27016684CY
Near Austin, TX 78733
Luis
Job Details: 07/19/2017
Refrigerator-KRMF606ESS01-failed icemaker,installed new icemaker
Near San Marcos, TX 78666
Diego G.
Job Details: 07/19/2017
Arrived on site. Replaced rails. Added silicone to cabinet. All functions tested OK. No leaks present. Job complete
Near San Marcos, TX 78666
Diego G.
Job Details: 07/19/2017
Arrived on site. Replaced rails. Added silicone to cabinet. All functions tested OK. No leaks present. Job complete
Near San Marcos, TX 78666
Diego G.
Job Details: 07/19/2017
Arrived on site. Replaced rails. Added silicone to cabinet. All functions tested OK. No leaks present. Job complete
Near Austin, TX 78702
Connor M.
Job Details: 07/19/2017
KUIX505ESS2 kitchenaid ice machine arrived on site to test unit for shutting off during use. Found external drain pump killing power to unit. Replaced and tested unit. Unit working properly, no leaks detected.
Near Austin, TX 78738
Cliff
Job Details: 07/19/2017
Kitchenaid oven KODE300ESS00. Arrived on site to diagnose an oven that is not keeping the proper temperature. Tested temperatures in the oven and found them to be correct. No calibration adjustments are needed on this unit. No other failures found and no other repairs are needed at this time.
Near Austin, TX 78750
Jerry C.
Job Details: 07/19/2017
W5CE3625AB00 Arrived to inspect damaged glass. I found the upper left corner was shattered within the box. I removed and replaced the cooktop with W10575101 and reassembled. The unit is uninstalled and cannot be tested at this time.
Near San Marcos, TX 78666
Diego G.
Job Details: 07/19/2017
Arrived on site. Replaced control box per service pointer. All functions tested OK. No leaks present. Job complete
Near San Marcos, TX 78666
Diego G.
Job Details: 07/19/2017
Arrived on site. Replaced control box per service pointer. All functions tested OK. No leaks present. Job complete
Near San Marcos, TX 78666
Diego G.
Job Details: 07/19/2017
Arrived on site. Replaced control box per service pointer. All functions tested OK. No leaks present. Job complete
Near Georgetown, TX 78633
Mike C.
Job Details: 07/19/2017
Whirlpool Range WFG540H0ES0 Arrived to check unit for oven temperature issues and two front burners not going low enough on low. Adjusted two front burners down at the gas valve to a lower setting. Set oven to 350 and found temperature to average out to 350. Unit checks good.
Near New Braunfels, TX 78130
Daniel A.
Job Details: 07/19/2017
WMH31017FS0 Excessive noise/buzzing sound from microwave while exhaust vent on. Not heating. Defective blower wheel on blower motor. Replaced vent/blower motor. Not heating due to defective magnetron/diode. Replaced mag-diode. Normal heat/sound/venting after service.
Near New Braunfels, TX 78130
Daniel A.
Job Details: 07/19/2017
WMH31017FS0 Excessive noise/buzzing sound from microwave while exhaust vent on. Not heating. Defective blower wheel on blower motor. Replaced vent/blower motor. Not heating due to defective magnetron/diode. Replaced mag-diode. Normal heat/sound/venting after service.
Near Leander, TX 78641
Jerry C.
Job Details: 07/19/2017
KDTE254ESS2 Arrived to inspect leaking. I found the unit with a 6-4 code stored. The rear wheels were off the floor and the unit was tilted forward 3/4 inch at the top and would move. I corrected the lean and tested. The customer has a water softener and was using tablets. The rinse agent dispenser was set to its highest level. I advised the customer to reduce the amount of detergent to one teaspoon, as they prerinse. I set and advised the customer to run the rinse agent at 1. I advised about the importance of purging cold water from the hot water supply prior to use. Operational test good, no leaks observed
Near Lakeway, TX 78738
Cliff
Job Details: 07/19/2017
Kitchenaid oven KEBS207BSS00. Arrived on site to diagnose an oven that is not turning on. Found thermal fuse for control board open and not allowing control to get power. Replaced thermal fuse and tested unit. Found all is functioning properly at this time.
Near Austin, TX 78746
Luis
Job Details: 07/19/2017
Ice machine-GI15NDXZS1-failed water valve installed updated water valve ran diagnostics all test passed
Near Austin, TX 78746
Luis
Job Details: 07/19/2017
Near Burnet, TX 78611
Thomas L.
Job Details: 07/19/2017
Arrived on site for unit not cooling. Found unit to have a leak in the fresh food evaporator and a very noisey compressor. Removed and replaced both. All water connections were dry. Kitchenaid French door frig model
Near Burnet, TX 78611
Thomas L.
Job Details: 07/19/2017
Near New Braunfels, TX 78130
Daniel A.
Job Details: 07/19/2017
WRS325FDAB06 Not dispensing cubed ice only crushed. Defectivevsolenoid. Plunger stuck in up position not allowing ice dispenser lever on bucket to open chute for whole cubes. Replaced defective solenoid for crushed/cubed. Verified dispenser motor operation. Normal operation after service
Near New Braunfels, TX 78130
Daniel A.
Job Details: 07/19/2017
WRS325FDAB06 Not dispensing cubed ice only crushed. Defectivevsolenoid. Plunger stuck in up position not allowing ice dispenser lever on bucket to open chute for whole cubes. Replaced defective solenoid for crushed/cubed. Verified dispenser motor operation. Normal operation after service
Near Belton, TX 76513
Mike G.
Job Details: 07/19/2017
KRMF706EBS01, Arrived on site for Ice is clumping. Water dispenser slowly, checked unit and found that the water valve to ice is not shuting all the way replaced water valve and tested unit and water valve is working properly checked unit for water leaks and no leaks found at time of srv.... Unit checked fine at this time....
Near Belton, TX 76513
Mike G.
Job Details: 07/19/2017
KRMF706EBS01, Arrived on site for Ice is clumping. Water dispenser slowly, checked unit and found that the water valve to ice is not shuting all the way replaced water valve and tested unit and water valve is working properly checked unit for water leaks and no leaks found at time of srv.... Unit checked fine at this time....
Near Austin, TX 78736
Luis
Job Details: 07/18/2017
Refrigerator-WRS571CIDM01-no ice failed icemaker,installed new icemaker
Near Austin, TX 78746
Wesley
Job Details: 07/18/2017
Near Cedar Park, TX 78613
Jerry C.
Job Details: 07/18/2017
MDE5500AYW Arrived to inspect noise. I found debris within the paddles and one of them had came loose. I removed the paddles and the debris within and reinstalled. I tested the unit and the issue was resolved. Operational test good, lint removed from cabinet.
Near Belton, TX 76513
Mike G.
Job Details: 07/18/2017
KDTE204ESS1, Arrived on site UNIT NOT PUT BACK CORRECTLY FROM PREVIOUS REPAIR AND INSULATION IS SHOWING, checked unit and found that the unit install Properly but insulation is getting pulled out on the right hand spring repositioned insulation from spring checked unit and unit checked fine at this time....