Near Taylor, TX 76574
Nathaniel B.
Job Details: 07/06/2018
Model MVWC360AW0, Arrived on call for makes a not normal noise in spin cycle, found prior that the gearcase and cam and belt and shield were bad replaced all parts today and tested and no water leaks after repair and no more noise complaints in spin cycle
Near Taylor, TX 76574
Nathaniel B.
Job Details: 07/06/2018
Model MVWC360AW0, Arrived on call for makes a not normal noise in spin cycle, found prior that the gearcase and cam and belt and shield were bad replaced all parts today and tested and no water leaks after repair and no more noise complaints in spin cycle
Near Taylor, TX 76574
Nathaniel B.
Job Details: 07/06/2018
Model KUDR24SEWH3, Arrived on call for when cycle is complete clean light does not reset and unit is not cleaning dishes and top rack is broken, found that dispenser will not lock will need dispenser, also will need all 4 wheels for top rack due to broken, and found that only normal cycle will start motor will only run but unit will not fill with water, found that interface switch and main control are bad wiring and valve checked good from check from the main control will need main control and control switch, will need research and autho. If parts are found, office will reschedule with customer if parts are found and if autho. Is approved, no water leaks at time of call.
Near Taylor, TX 76574
Nathaniel B.
Job Details: 07/06/2018
Model KUDR24SEWH3, Arrived on call for when cycle is complete clean light does not reset and unit is not cleaning dishes and top rack is broken, found that dispenser will not lock will need dispenser, also will need all 4 wheels for top rack due to broken, and found that only normal cycle will start motor will only run but unit will not fill with water, found that interface switch and main control are bad wiring and valve checked good from check from the main control will need main control and control switch, will need research and autho. If parts are found, office will reschedule with customer if parts are found and if autho. Is approved, no water leaks at time of call.
Near Cedar Park, TX 78613
Lou
Job Details: 07/06/2018
arrived on site to inspect washer showing error codes. Upon further inspection, I placed the unit in diagnostics and tested. Unit dispensed the cold water and stopped. Error code 6/1 appeared. I removed and replaced the MCU and tested unit. Unit operated as designed. No water leaks observed during service. Job completed.
Near Georgetown, TX 78633
Thomas L.
Job Details: 07/06/2018
Near Killeen, TX 76543
Arthur B.
Job Details: 07/06/2018
ADB1400AGB1 (Dishwasher) - Arrived onsite for customer complaint of door not closing properly causing not start on dishwasher. Found strike had bent downward blocking the latch. Also found no mounting brackets securing unit. Was able to adjust strike. Door now closes properly. Will need to order 2x under counter brackets to complete repair. R/S for Tuesday 7/10. All water connections were dry at time of service.
Near Taylor, TX 76574
Nathaniel B.
Job Details: 07/06/2018
Model KDTE234GWH0, Arrived on call for dishwasher will not start intermittently, previous tech found bad keys on touch panel on dishwasher, replaced touch panel, not able to test customer is doing a remodel on kitchen unit is not installed or hooked up, call complete.
Near Taylor, TX 76574
Nathaniel B.
Job Details: 07/06/2018
Model KDTE234GWH0, Arrived on call for dishwasher will not start intermittently, previous tech found bad keys on touch panel on dishwasher, replaced touch panel, not able to test customer is doing a remodel on kitchen unit is not installed or hooked up, call complete.
Near Austin, TX 78745
Brandon
Job Details: 07/06/2018
Arrived on site for washer tub out of balance, I adjusted the suspension rod, and calibrated unit, tested good
Near Canyon Lake, TX 78133
Diego G.
Job Details: 07/06/2018
Arrived on site. Check for leaking issues. Found clogged drain in refrigerator compartment. Unclogged drain, all functions tested OK. No leaks present. Job complete
Near Canyon Lake, TX 78133
Diego G.
Job Details: 07/06/2018
Arrived on site. Check for leaking issues. Found clogged drain in refrigerator compartment. Unclogged drain, all functions tested OK. No leaks present. Job complete
Near Canyon Lake, TX 78133
Diego G.
Job Details: 07/06/2018
Arrived on site. Check for leaking issues. Found clogged drain in refrigerator compartment. Unclogged drain, all functions tested OK. No leaks present. Job complete
Near Austin, TX 78725
Joseph C.
Job Details: 07/06/2018
WED4815EW1 Arrived on site for “taking two or three cycles to dry clothes completely” complaint. Inspected unit and found clogged vent line. Builder came on site and cleared vent line to outer wall. Retested unit. Unit is performing as designed. Instructed customer to clean venting every six months, to prevent possible fire hazards and for better performance and economy.
Near Georgetown, TX 78628
Thomas L.
Job Details: 07/06/2018
Arrived on site for high temps in fresh food section. Found,title air coming into fresh food section from freezer section. Removed small ice blockage from return vent. All water connections were dry at the time of service.
Near Killeen, TX 76542
Arthur B.
Job Details: 07/06/2018
LSR8233EQ1 (Top Load Washer) - Arrived onsite for customer complaint of top load washer overfilling and not washing. Found pressure hose to water level switch is warn out and not staying secure to switch. Removed water level switch and pressure hose and installed new replacements. Reassembled. Tested unit. Unit now fills,agitates, drains and spins as intended. Previous service company has cut the door switch harness to bypass. Customer is aware. No other issues found. All water connections were dry at time of service.
Near Blanco, TX 78606
Robert
Job Details: 07/06/2018
KDTM354ESS3 Arrived on job for complaints of not draining. Found loose connection on drain motor. After correcting wire issue test unit operation normal and no leaks detected. Job complete
Near Pflugerville, TX 78660
Nathaniel B.
Job Details: 07/06/2018
Model WZF34X16DW04, Arrived on call for freezer cabinet feels warm, found that unit is in garage and amb. Conditions are to high instructed customer to keep garage door cracked and a fan blowing on the back compressor area and if issues with unit stop cooling returns customer will need to move unit inside until cooler months return, as for heat on outside cabinet wall is normal this unit has no external condenser heat is exchanged from the side cabinet walls, instructed customer if unit continues to intermittently stop cooling will need to move unit in home due to it is to hot of conditions to run under in the garage it is to hot in the garage, also found outlet that unit is plugged in to is a gfci outlet which will need to be changed to a standard outlet which could also cause unit to shut down, customer to have outlet changed to a standard 120 ac outlet, no parts needed, call complete
Near Pflugerville, TX 78660
Nathaniel B.
Job Details: 07/06/2018
Model WZF34X16DW04, Arrived on call for freezer cabinet feels warm, found that unit is in garage and amb. Conditions are to high instructed customer to keep garage door cracked and a fan blowing on the back compressor area and if issues with unit stop cooling returns customer will need to move unit inside until cooler months return, as for heat on outside cabinet wall is normal this unit has no external condenser heat is exchanged from the side cabinet walls, instructed customer if unit continues to intermittently stop cooling will need to move unit in home due to it is to hot of conditions to run under in the garage it is to hot in the garage, also found outlet that unit is plugged in to is a gfci outlet which will need to be changed to a standard outlet which could also cause unit to shut down, customer to have outlet changed to a standard 120 ac outlet, no parts needed, call complete
Near Canyon Lake, TX 78133
Diego G.
Job Details: 07/06/2018
Arrived on site. Found refrigerator not cooling at all from previous visit. After further diagnosis found leak at discharge line going to compressor. Repaired weld and vacuum system. Charge unit 5.3 ounces. Also replaced auger motor and tested dispenser all checked OK. Instructed customer to allow 24 hours for unit to get down to temperature completely. No leaks present. Job complete
Near Canyon Lake, TX 78133
Diego G.
Job Details: 07/06/2018
Arrived on site. Found refrigerator not cooling at all from previous visit. After further diagnosis found leak at discharge line going to compressor. Repaired weld and vacuum system. Charge unit 5.3 ounces. Also replaced auger motor and tested dispenser all checked OK. Instructed customer to allow 24 hours for unit to get down to temperature completely. No leaks present. Job complete
Near Canyon Lake, TX 78133
Diego G.
Job Details: 07/06/2018
Arrived on site. Found refrigerator not cooling at all from previous visit. After further diagnosis found leak at discharge line going to compressor. Repaired weld and vacuum system. Charge unit 5.3 ounces. Also replaced auger motor and tested dispenser all checked OK. Instructed customer to allow 24 hours for unit to get down to temperature completely. No leaks present. Job complete
Near Cedar Park, TX 78613
Lou
Job Details: 07/06/2018
arrived on site to inspect cooktop ignitors constantly sparking. Upon further inspection, the customer advised that the back left Ignitor won't stop sparking. I found that all of the ignitors are sparking and won't stop. Also, I found that two of the valves are sticking but are not causing the ignitors to spark all the time. They were in the off position and the ignitors continued to spark and all knobs need to be replaced. I am ordering a spark module, valve manifold, wiring harness and four knobs SS. Scheduled return service for 07/12/18. No gas leaks detected during service.
Near Killeen, TX 76549
Arthur B.
Job Details: 07/06/2018
RF264LXSB0 (Freestanding Range) - Arrived onsite for customer complaint of freestanding range large element not heating properly. Removed back panel and found both infinite switches burnt. Also found receptacle warn out and not making proper contact to coil. Will need both large infinite switches, 1 large coil and 2 receptacles to complete repair. R/S for Monday 7/9. No other issues found.
Near Leander, TX 78641
Thomas L.
Job Details: 07/06/2018
Near Austin, TX 78704
Scott
Job Details: 07/06/2018
Near Austin, TX 78704
Scott
Job Details: 07/06/2018
Arrived on site for unit not starting . Unit is not draining , found broken glass ,rubber and, and a bunch of what looks like hair in drain pump propellers . Cleaned out all foreign debris. Ran diagnostics test all checked out normal . Labor only 159.99. Collected 173.19 cc. No water leaks detected at time of service . Job complete .
Near Austin, TX 78746
Kevin
Job Details: 07/06/2018
Arrived on site and replaced adapter fan kit from previous visit recommended by tech line. Requested that customer monitor refrigerator for correct operation, no water leaks from connections at time of service, job complete.
Near Killeen, TX 76549
Arthur B.
Job Details: 07/06/2018
WRS965CIAM00 (SxS Refrigerator) - Arrived onsite for customer complaint of SxS refrigerator not making ice. Removed icemaker cover and found icemaker stopped mid harvest. Removed ice maker assembly and installed new replacement. Tested icemaker. Found icemaker called for water but no water was dispensed. Used at wire to check fill tube and found blockage 1/2 down the tube. Per IPL, fill tube assembly is no a part serviceable. Will need to order freezer door assembly. Advise customer of findings. AHS must approve door before we can proceed. OF to R/S. All water connections were dry at time of service.
Near Austin, TX 78728
Nathaniel B.
Job Details: 07/06/2018
Model NGD4655EW1, Arrived on call for long dry times from dryer, found wall vent is restricted it is blowing air out from lint filter when is to pull down and vent hose is not kinked behind dryer see pic, customer to not run dryer until wall vent is cleared due to this is a fire hazard, customer to contact dryer wall vent cleaning service, no parts needed, call complete, dryer is still heating.
Near Austin, TX 78728
Nathaniel B.
Job Details: 07/06/2018
Model NGD4655EW1, Arrived on call for long dry times from dryer, found wall vent is restricted it is blowing air out from lint filter when is to pull down and vent hose is not kinked behind dryer see pic, customer to not run dryer until wall vent is cleared due to this is a fire hazard, customer to contact dryer wall vent cleaning service, no parts needed, call complete, dryer is still heating.
Near Kingsland, TX 78639
Jerry C.
Job Details: 07/06/2018
GEW9250PW1 Arrived to instal previously diagnosed and ordered parts. I found the issue was within the UI and after replacing, all functions were present and normal operations resumed. Operational test good, lint removed from unit.
Near Austin, TX 78728
Nathaniel B.
Job Details: 07/06/2018
Model WED4815EW1, Arrived on call for dryer not heating, found high limit fuse open and hearing element showing open, wall vent is clear has good pull down from lint filter, replaced element and cut off and checked operation and all checks good unit is know heating, will need door handle due to broken, will reschedule for 7/10/18
Near Austin, TX 78728
Nathaniel B.
Job Details: 07/06/2018
Model WED4815EW1, Arrived on call for dryer not heating, found high limit fuse open and hearing element showing open, wall vent is clear has good pull down from lint filter, replaced element and cut off and checked operation and all checks good unit is know heating, will need door handle due to broken, will reschedule for 7/10/18
Near Georgetown, TX 78628
Thomas L.
Job Details: 07/06/2018
Near Waco, TX 76712
Mike G.
Job Details: 07/06/2018
MED9800TQ0, Arrived on site for unit not heating checked unit and found that the heating element is bad replaced heating element and cleaned out all lent found from unit and tested unit and unit is now heating and has good air flow unit checked fine at this time....
Near Waco, TX 76712
Mike G.
Job Details: 07/06/2018
MED9800TQ0, Arrived on site for unit not heating checked unit and found that the heating element is bad replaced heating element and cleaned out all lent found from unit and tested unit and unit is now heating and has good air flow unit checked fine at this time....
Near Cedar Park, TX 78613
Lou
Job Details: 07/06/2018
arrived on site to inspect venthood light being cracked. Upon further inspection, I found that the venthood left light was broken and needed to be replaced. I removed and replaced the light and tested it. The light operated as designed. Job completed.
Near Copperas Cove, TX 76522
Arthur B.
Job Details: 07/06/2018
WDT730PAHZ0 (Dishwasher) - Arrived onsite to install new control and sump n motor to dishwasher from my prior visit’s diagnosis. Removed sump n motor, control and installed new replacements. Reassembled and tested. Unit now fills,washes,drain and heats as intended. No other issues found. All water connections were dry at time of service.
Near Georgetown, TX 78626
Thomas L.
Job Details: 07/06/2018
Near Leander, TX 78641
Lou
Job Details: 07/06/2018
arrived on site to inspect washer not draining. Upon arrival, the customer advised that the last wash she did there was approximately 2 inches of water in the tub after pulling her clothing out. I found that the water was off and the unit was unplugged. I turned the water on and a plugged the unit in and immediately water started trickling into the unit. I placed the unit in diagnostics and manually drained the unit. The was no standing water in the tub when I arrived. After draining the unit, I checked for error codes and found 8/1 and 8/3. I ran the unit in diagnostics and the unit operated as designed; however, water continued to trickle from the valve during testing. I am ordering a water inlet valve housing and scheduled return service for 07/12/18. No water leaks observed during service.
Near Kyle, TX 78640
Kevin
Job Details: 07/06/2018
site and found a Lego in the drain pump that has stopped it from working. Replaced drain pump. No water leaks from connections at time of service, job complete
Near Georgetown, TX 78626
Thomas L.
Job Details: 07/06/2018
Near Copperas Cove, TX 76522
Arthur B.
Job Details: 07/06/2018
KRMF706ESS01 (5 Door Refrigerator) - Arrived onsite for customer complaint of ice not dispensing ice intermittently. Removed ice chute plate and dispenser motor. Found ice dispenser motor had a bad seal causing bad rotation in where the motor turns the shaft. Removed motor and installed new dispenser motor and ice chute plate. Reassembled. Tested multiple time and found no delay in dispensing. No other issues found. All water connections were dry at time of service.
Near Manor, TX 78653
Joseph C.
Job Details: 07/05/2018
WRF535SWHZ00 Arrived on site for “not cooling in fresh foods section” complaint. Inspected unit and found thermistors faulty. Removed and replaced thermistors. Unit is performing as designed. No leaks detected, at time of service.
Near Manor, TX 78653
Joseph C.
Job Details: 07/05/2018
110.87721701 Arrived on site for “no heat when spinning” complaint. Inspected unit and found high limit thermostat blown. Removed and replaced thermostat. Tested unit. Unit is performing as designed. No leaks detected, at time of service.
Near Austin, TX 78717
Lou
Job Details: 07/05/2018
arrived on site to inspect oven not working. On the previous service call, the unit was not wired correctly and the customer had the builder come and check it. The customer advised that the builder pulled the unit from the wall and checked the wiring and did in fact have to re-wire the electrical. Upon further inspection today, the unit was still showing error codes. I cleared the codes and attempted to test the unit, but it showed the same error codes again. I removed and replaced the main control board and tested the unit and the unit operated as designed. Job completed.
Near Austin, TX 78717
Lou
Job Details: 07/05/2018
arrived on site to install previously diagnosed and ordered part. I installed the microwave light, not the venthood light, and tested the unit and the unit operated as designed. Job completed.
Near Elgin, TX 78621
Nathaniel B.
Job Details: 07/05/2018
Model WFW75HEFW0, Arrived on call for washer not washing cloths or spinning cloths properly, found prior failed drain pump, replaced drain pump today and ran auto test and unit went all the way through auto diag., all checked good, pressure switch and trap and pressure hose not needed and no errors after running auto test, no leaks after repair call complete. Also instructed customer on soap usage.
Near Elgin, TX 78621
Nathaniel B.
Job Details: 07/05/2018
Model WFW75HEFW0, Arrived on call for washer not washing cloths or spinning cloths properly, found prior failed drain pump, replaced drain pump today and ran auto test and unit went all the way through auto diag., all checked good, pressure switch and trap and pressure hose not needed and no errors after running auto test, no leaks after repair call complete. Also instructed customer on soap usage.
Near Elgin, TX 78621
Nathaniel B.
Job Details: 07/05/2018
Model WRF767SDEM01, Arrived on call for noise from freezer, found ive forming directly below fan blade, replaced adapter with new fan and added permigum to adapter and sealed were inside liner meets outer cabinet on both sections and replaced freezer evap fan and all checks good, no water leaks after repair, call complete.
Near Elgin, TX 78621
Nathaniel B.
Job Details: 07/05/2018
Model WRF767SDEM01, Arrived on call for noise from freezer, found ive forming directly below fan blade, replaced adapter with new fan and added permigum to adapter and sealed were inside liner meets outer cabinet on both sections and replaced freezer evap fan and all checks good, no water leaks after repair, call complete.
Near Killeen, TX 76542
Arthur B.
Job Details: 07/05/2018
ED5VHEXVB02 (SxS Refrigerator) x Arrived onsite to replace thermostat on SxS refrigerator from prior tech diagnosis. Removed old thermostat and installed new replacement. Reassembled. Tested unit. Hooked up gauges and found high side over 350psi. Found restriction in dye drier. Removed dryer drier and installed new dryer drier WPW10143759 from truck stock using braising methods. Vacuumed system down to -25PSI. Charged with 5.0oz of R134a refrigerant. Tested unit. Pressure on high side was @180psi,low side @4psi. Good air flow and frost pattern on evaporator. No other issue found. No water connections made to unit since unit was moved into garage.
Near Leander, TX 78641
Lou
Job Details: 07/05/2018
arrived on site to inspect dryer not heating well. Upon further inspection, I verified voltage at the outlet and terminal block on the unit. I placed the unit in diagnostics and checked for error codes. I checked the vent hose coming out of the unit and found it crimped together so I shaped it open. I found error codes 4/3 and 4/4. I had already verified voltage to the unit. I cleared the codes and ran the unit in diagnostics. No further error codes. I used my vent testing materials and tested the venting and found that the unit is venting well. I used my thermal couple to verify temperature inside at the vent which got up to 208. I verified ohms at all the components...fuse, cutoff, and element. I questioned the customer on use and found that the unit is being operated on different modes for different items. I found nothing wrong with this unit at this time and advised the customer on proper use of the unit. No lint observed during service.
Near Leander, TX 78641
Lou
Job Details: 07/05/2018
arrived on site to inspect dishwasher not washing. Upon further inspection, I found that the soap was not being dissolved and the unit was not washing. I placed the unit in diagnostics and tested and the unit motor did not come on and was showing error code 9/1. Also, I found that both tracks were bound and twisted to a point to where the upper rack was falling off and the rear stops were worn and not stopping the rack from falling either. Also, I found that some of the wheels were missing from the upper rack. I am ordering a sump/motor assembly, both tracks, four tub wheels, four rack wheels and two rear stops and scheduled return service for 07/10/18. No water leaks observed during service.
Near Belton, TX 76513
Mike G.
Job Details: 07/05/2018
MVWC565FW0, Arrived on site for unit not power on checked unit and found that when unit is plugged in drain pump turns on cancel unit out and recalibrated unit and retested unit and fou d that the unit is now filling washing and draining and spining and lid is locking and unlocking checked unit for water leaks and no leaks found at time of srv.... unit checked fine after recalibrating....
Near Belton, TX 76513
Mike G.
Job Details: 07/05/2018
MVWC565FW0, Arrived on site for unit not power on checked unit and found that when unit is plugged in drain pump turns on cancel unit out and recalibrated unit and retested unit and fou d that the unit is now filling washing and draining and spining and lid is locking and unlocking checked unit for water leaks and no leaks found at time of srv.... unit checked fine after recalibrating....
Near Kyle, TX 78640
Robert
Job Details: 07/05/2018
WED5000DW2 Arrived on job to replace timer. After replacement of timer test air flow and heat. Operation normal job complete.
Near Bastrop, TX 78602
Nathaniel B.
Job Details: 07/05/2018
Model MEDB765FC0, Arrived on call for dryer not heating, checked for error codes and got f4 e4 which is a l2 line voltage error, checked ac volts on l2 to ground at outlet and only got 12.9 ac volts, customer to contact a electrician, dryer wall vent is clear,, call complete.
Near Bastrop, TX 78602
Nathaniel B.
Job Details: 07/05/2018
Model MEDB765FC0, Arrived on call for dryer not heating, checked for error codes and got f4 e4 which is a l2 line voltage error, checked ac volts on l2 to ground at outlet and only got 12.9 ac volts, customer to contact a electrician, dryer wall vent is clear,, call complete.
Near Killeen, TX 76542
Arthur B.
Job Details: 07/05/2018
ED5FHEXSB00 (SxS Refrigerator) - Arrived onsite to install new condenser fan motor to SxS refrigerator from my prior visit’s diagnosis. Removed back unit cover and removed faulty condenser fan motor. Installed updated replacement. Reassembled. Tested unit. Unit now runs quietly as intended. No other issues found. All water connections were dry at time of service.
Near Killeen, TX 76542
Arthur B.
Job Details: 07/05/2018
RF369LXPB3 (Freestanding Range) - Arrived onsite to install oven control to freestanding range from my prior visit’s diagnosis. Removed control and installed new replacement. Reassembled and tested. All functions/features now works as intended. No other issues found at this time.
Near Bastrop, TX 78602
Nathaniel B.
Job Details: 07/05/2018
Model WRF993FIFM00, Arrived on call for fresh food evap cover iced over, customer had unit unthawed when got to location, replaced evap cover and main control and sealed around drain tube cup and were inside liner meets outer cabinet on both sections, customer to allow for 24-48 hours for proper cooling, no water leaks at time of call, call complete.
Near Bastrop, TX 78602
Nathaniel B.
Job Details: 07/05/2018
Model WRF993FIFM00, Arrived on call for fresh food evap cover iced over, customer had unit unthawed when got to location, replaced evap cover and main control and sealed around drain tube cup and were inside liner meets outer cabinet on both sections, customer to allow for 24-48 hours for proper cooling, no water leaks at time of call, call complete.
Near Killeen, TX 76542
Arthur B.
Job Details: 07/05/2018
WRF993FIFM00 (French Door Dual Evaporator Refrigerator) - Arrived onsite for customer for customer complaint of French door refrigerator not making ice in RC section. Checked temperatures innRC section and found @50F, FC section @10F. Ran test 40 to verify 3Way valve and found valve working as intended. Call WPL Techline 772238720 and advised to also run test 128,129. All pass. Advised to change evaporator cover,rear control,Orion board,dual valve and both icemakers per service pointer. Advised customer that will need to order parts. Customer will defrost 24hrs prior to return visit on 7/10. All water connections were dry at time of service.
Near Temple, TX 76504
Mike G.
Job Details: 07/05/2018
MVWC565FW0, Arrived on site for unit will not go pass wash checked unit and fou d that the lid lock is bad and will not lock lid replaced lid lock and checked unit and unit is now locking and unlocking and is now working properly checked unit for water leaks and no leaks found at time of srv.... unit checked fine at this time.....
Near Temple, TX 76504
Mike G.
Job Details: 07/05/2018
MVWC565FW0, Arrived on site for unit will not go pass wash checked unit and fou d that the lid lock is bad and will not lock lid replaced lid lock and checked unit and unit is now locking and unlocking and is now working properly checked unit for water leaks and no leaks found at time of srv.... unit checked fine at this time.....
Near Austin, TX 78746
Kevin
Job Details: 07/05/2018
Arrived on site And found no cooling and no frost pattern on evaporator, inspected compressor and found it is very hot to the touch and voltage to it is correct. Compressor has failed and will need to be replaced. No water leaks from connections at time of service scheduled for July 23 per customer request
Near Killeen, TX 76542
Arthur B.
Job Details: 07/05/2018
RF368LXPB2 (Freestanding Range) - Arrived onsite for customer complaint of freestanding range bake feature not coming on. Removed back cover and found terminal block shorted and melted. Also found plug itself on the spade shorted out as well. Advised customer to have receptacle and outlet changed prior to return. Unit will need new terminal block. R/S for Tuesday 7/10. Unit is unplugged at this time to prevent any other damage.
Near Jonestown, TX 78645
Lou
Job Details: 07/05/2018
arrived on site to install previously diagnosed and ordered part. I removed and replaced the main control due to the unit making an echo beeping sound at the end of the cook time. I tested the unit five times to verify that the noise stopped by replacing the control and the unit operated as designed. Job completed.
Near Jonestown, TX 78645
Lou
Job Details: 07/05/2018
arrived on site to inspect oven taking too long to heat. Upon further inspection, I found that this is a new unit that has never been used. I placed a rack in the center of the unit and placed my thermal couple in the center of said center rack. I turned the unit on bake at 350 degrees and proceeded with testing. The unit beeped after 10 mins telling me it was at 350 degrees; however, my thermal couple reading was 299-300. I continued with testing with my readings as follows...362, 336, 366, 341, and 351 and after approximately 35-40 mins of testing, my average reading was 351. I notified the builder of my findings. I never had to remove the unit from the wall during testing. Job completed.
Near Austin, TX 78758
Scott
Job Details: 07/05/2018
Arrived on site for left rear burner not sparking . Found loose connection on spark module . Reconnected wire and all burners are now functioning as designed . No gas leaks detected at time of service . Job complete . May tag cook top
Near Leander, TX 78641
Lou
Job Details: 07/05/2018
arrived on site to inspect cooktop burner flame not adjusting. Upon further inspection, I found that the right rear burner would stay the same height form high to low settings. I placed the knob/burner valve on low and adjusted the flame to the lowest setting without the flame going out. I tested the burner and it operates as designed. I adjusted the remaining burners, as well. . I had to remove the bottom oven unit in order to get a picture of the placard and I took photos of prior damage to trim around the oven before removing the unit. No gas a leaks observed during service. I notified the builder of my findings and service.
Near Killeen, TX 76542
Arthur B.
Job Details: 07/05/2018
WRV986FDEM01 (5 Door French Door Refrigerator) - Arrived onsite for customer complaint of French door refrigerator keeps resetting itself and getting PF error codes on UI. Confirmed issue when arrived. Unit will need new UI,control,inverter to complete repair. Unit is cooling as intended minus the resetting issue. Advised customer that authorization is needed from AHS for parts. OF to R/S customer. All water connections were dry at time of service.
Near Little River-Academy, TX 76554
Mike G.
Job Details: 07/05/2018
MEDC300BW0, Arrived on site for unit not starting, checked unit and found that the door switch is broken and needs to be replaced, replaced door switch and checked and cleaned out all lent found from unit and tested unit and found thatbthe unit is now starting and heating and unit has good air flow unit checked fine at this time....
Near Little River-Academy, TX 76554
Mike G.
Job Details: 07/05/2018
MEDC300BW0, Arrived on site for unit not starting, checked unit and found that the door switch is broken and needs to be replaced, replaced door switch and checked and cleaned out all lent found from unit and tested unit and found thatbthe unit is now starting and heating and unit has good air flow unit checked fine at this time....
Near Austin, TX 78723
Joseph C.
Job Details: 07/05/2018
KRFC704FSS00 Arrived on site for “no ice production” complaint. Inspected unit and found wire broken from fill tube heater. Ordering new left door. Office to set return schedule, due to door needing to be manufactured. No leaks detected, at time of service.
Near Georgetown, TX 78633
Thomas L.
Job Details: 07/05/2018
Near Georgetown, TX 78633
Jerry C.
Job Details: 07/05/2018
WFG530S0ES1 Arrived to inspect gas odor during oven use. I found the bake and broil gas mixtures set all the way open, allowing too lean of an air-fuel ratio and causing incomplete burn, causing the characteristic “blowtorch” sound and excessive raw gas odor. I set both air intakes to the correct mixture and tested. I advised the customer to utilize the venting system within the micro-hood and verified correct operations. No gas leaks detected during service.
Near Killeen, TX 76542
Arthur B.
Job Details: 07/05/2018
KMHS120ESS3 (OTR Microwave) - Arrived onsite for customer complaint of OTR microwave getting OPEN/CLOSE door error and interior light not coming on. Removed console and found door switches burnt. Removed NC,NO and 3 way switch. Also replace control as well. Reassembled. Tested unit. Unit heats as intended with no errors.
Near Austin, TX 78731
Kevin
Job Details: 07/05/2018
Arrived on site and replace bottom grill kit diagnosed by previous technician, Their refrigerator does not have enough spacing under it for both pieces. Installed metal piece and attached to brackets. Plastic dust cover will not fit but left them with the customer as they may be able to modify them. Job complete
Near Austin, TX 78746
Leonardo
Job Details: 07/05/2018
Whirlpool dishwasher not drying model: WDT720PADM2. Arrived on site to test unit for not drying. Test unit and found f7e1 test heater and found opened heating element. Replaced element test unit for leaks no leaks present at this time. Heater coming on and heating up. Job complete
Near Austin, TX 78754
Joseph C.
Job Details: 07/05/2018
WED4815EW1 Arrived on site for “no operation” complaint. Per my previous diagnosis, removed and replaced motor and wheel. Tested unit. Unit is performing as designed. Instructed customer to clean venting every six months to prevent possible fire hazards and for better performance and economy.
Near Georgetown, TX 78633
Thomas L.
Job Details: 07/05/2018
Near Austin, TX 78758
Scott
Job Details: 07/05/2018
Arrived on site for loud clacking sound and ,freezer light not coming on intermittently . Found dampener control making a pound noise when it’s opening and closing ,no ice build up visible . Ordering control ,return 7/7. In freezer found the cross bar on rails had fallen out causing the door to sometimes leave a small gap in seal allowing moisture to collect around door switch . Reinstalled guide bar and now is tight seal around door ,an wiped away moisture .no water leaks detected at time of service .
Near Austin, TX 78749
Kevin
Job Details: 07/05/2018
Arrived on site and inspected dryer and found squeaking noise coming from wheels when drum is turning. Will need to bring back a dryer kit to correct the issue. Also found F4E3 and F4E4 recommended to customer that vent to exterior of home be cleaned as it has not been done in recent memory. Will remove any built up lint from the interior when the support wheels are replaced.
Near Austin, TX 78746
Luis
Job Details: 07/05/2018
Icemachine-replaced failed main control
Near Harker Heights, TX 76548
Arthur B.
Job Details: 07/05/2018
WDF760SADM2 (Dishwasher) - Arrived onsite for customer complaint of dishwasher not washing dishes and not drying dishes. Tested unit and found sump not pumping water. Removed faulty sump and motor and installed new replacement. Reassembled. Tested unit. Unit now fills,washes,drain and heats as intended. No other issues found. All water connections were dry at time of service.
Near Dripping Springs, TX 78620
Brandon
Job Details: 07/05/2018
Arrived on site for part hanger, I installed adapter and fan motor, unit tested good. Water lines were dry at time of service.
Near Georgetown, TX 78633
Thomas L.
Job Details: 07/05/2018
Arrived on site for no drain condition. Drain water and found failed drain pump.
Near Leander, TX 78641
Lou
Job Details: 07/04/2018
arrived on site to install previously diagnosed and ordered part. Removed and replaced the ice maker due to it not making ice. I tested the unit and the new ice maker operated as designed as it filled with water and I tested the motor with my jump wire and the motor operated as designed as well. I advised the customer to purge the ice every so often to keep the ice from building up at the back of the bin. No water leaks observed during service
Near Kyle, TX 78640
Kevin
Job Details: 07/04/2018
Arrived on site and found no interior lights in refrigerator, replaced LED control board and lights are now operating properly. No water leaks from connections at time of service, job complete
Near Austin, TX 78750
Luis
Job Details: 07/04/2018
Refrigerator-replaced failed icemaker
Near Austin, TX 78735
Brandon
Job Details: 07/04/2018
Arrived on site for customer complaint of out of balance and really loud noises, found bearings were bad and need replacing. Quoted customer, they are going to buy a new washer.
Near Pflugerville, TX 78660
Nathaniel B.
Job Details: 07/03/2018
Model WRS325FDAB02, Arrived on call for fresh food side not going below 63 degrees, found evap fan not running at proper speed and damper broken and fan not turning on when set to coldest setting will replace control and t-stat and damper and evap fan, replaced all parts and know getting proper air flow to fresh food section, customer to allow for 12-24 hours for proper cooling, also sealed were inside liner meets outer cabinet on both sections due to large gaping, call complete, no water leaks at time of call.
Near Pflugerville, TX 78660
Nathaniel B.
Job Details: 07/03/2018
Model WRS325FDAB02, Arrived on call for fresh food side not going below 63 degrees, found evap fan not running at proper speed and damper broken and fan not turning on when set to coldest setting will replace control and t-stat and damper and evap fan, replaced all parts and know getting proper air flow to fresh food section, customer to allow for 12-24 hours for proper cooling, also sealed were inside liner meets outer cabinet on both sections due to large gaping, call complete, no water leaks at time of call.
Near Buda, TX 78610
Kevin
Job Details: 07/03/2018
Arrived on site and found saved error codes, 8/2 cold incoming water 9/1 slow drain, incoming water measured at kitchen faucet only reaches 112 degrees. recommended raising water temp to Whirlpool minimum of 120 degrees. Drain pump is Operating correctly but recommended dishwasher magic in order to clear any build up. No water leaks from connections at time of service, job complete
Near Leander, TX 78641
Lou
Job Details: 07/03/2018
arrived on site to inspect venthood falling apart. Upon further inspection, the customer provided me with a dismantled venthood filter. I also found that the fan blade was melted which caused the dismantling of the filter. Looking further into the unit, I found that due to extreme heat/high flame, the fan motor connector was slightly melted, but the fan still operates. I advised the customer that I will order a fan motor assembly and scheduled return service for 07/09/18 and advised that the office would contact them to schedule a time frame. I advised the customer to not use the unit until the part was replaced.
Near Austin, TX 78747
Luis
Job Details: 07/03/2018
Refrigerator-installed updated icemaker kit
Near Georgetown, TX 78628
Thomas L.
Job Details: 07/03/2018