Near Belton, TX 76513
Dona
Job Details:
04/27/2018
Arrived on site for no operation, found motor seized, water level switch defective. Customer stated hat it has not worked one time and do not want fixed, they are returning unit for an exchange. Erika assisted. All water connections are dry.
Near Hewitt, TX 76643
Mike G.
Job Details:
04/27/2018
WDT780SAEM1, Arrived on site for unit not cleaning or drying, checked unit and found 7-1 error code for no heat Has been disabled, ran test cycle on unit and found that unit will fill, wash and drain and element is heating found that the OWI sensor is bad and will need to be replaced ordering part checked unit for water leaks and no leaks found at time of srv.... per SW r/s next apt for 5/3/18
Near Hewitt, TX 76643
Mike G.
Job Details:
04/27/2018
WDT780SAEM1, Arrived on site for unit not cleaning or drying, checked unit and found 7-1 error code for no heat Has been disabled, ran test cycle on unit and found that unit will fill, wash and drain and element is heating found that the OWI sensor is bad and will need to be replaced ordering part checked unit for water leaks and no leaks found at time of srv.... per SW r/s next apt for 5/3/18
Near Georgetown, TX 78633
Thomas L.
Job Details:
04/27/2018
Removed and replaced right rear burner valve. Valve was bound up and would not turn. Tested for gas leaks and none were found. All burners are now working properly.
Near Round Rock, TX 78681
Nathaniel B.
Job Details:
04/27/2018
Model MET8776BS00, Arrived on call for no power to unit, found outside breaker had tripped so turned breaker back on and all of unit is running ran ovens and all top burners and voltages at terminal block and outlet are good, customer will need to contact a electrician to have outlet and breaker checked due to posable faulty breaker or connection in outlet did get a flash from outlet when unplugging it, customer to contact a electrician.
Near Round Rock, TX 78681
Nathaniel B.
Job Details:
04/27/2018
Model MET8776BS00, Arrived on call for no power to unit, found outside breaker had tripped so turned breaker back on and all of unit is running ran ovens and all top burners and voltages at terminal block and outlet are good, customer will need to contact a electrician to have outlet and breaker checked due to posable faulty breaker or connection in outlet did get a flash from outlet when unplugging it, customer to contact a electrician.
Near Austin, TX 78617
Joseph C.
Job Details:
04/26/2018
WDF520PADM7 Arrived on site for “dispenser door broken” complaint. Inspected unit and found dispenser door broken. Removed and replaced dispenser. Tested unit. Unit is performing as designed. No leaks detected, at time of service.
Near New Braunfels, TX 78132
Connor M.
Job Details:
04/26/2018
WDT780SAEM2 whirlpool dishwasher Arrived on site to test unit for upper rack issue. Fiund both adjusters had rollers broken off. Replaced with new adjuster kit. Unit working properly. Attached picture of work order for lowes installers dating 5/25 which makes unit in warranty. No leaks detected.
Near Pflugerville, TX 78660
Nathaniel B.
Job Details:
04/26/2018
Model MVWB835DW3, Arrived on call for inlet valve sensor showing open or shorted, installed valve and all checks good after testing, error code did not return, call complete, no water leaks after repair.
Near Pflugerville, TX 78660
Nathaniel B.
Job Details:
04/26/2018
Model MVWB835DW3, Arrived on call for inlet valve sensor showing open or shorted, installed valve and all checks good after testing, error code did not return, call complete, no water leaks after repair.
Near Leander, TX 78641
Lou
Job Details:
04/26/2018
arrived on site to install previously diagnosed and ordered parts. Removed and replaced the UI and main control. Tested the unit and unit operated as designed. No water leaks observed during service.
Near New Braunfels, TX 78130
Connor M.
Job Details:
04/26/2018
WRT311FZDW whirlpool refrigerator Arrived on site to install door for liner damage. Installed and checked for proper fitting shelves. Unit working properly, no leaks detected.
Near Austin, TX 78738
Brandon
Job Details:
04/26/2018
Arrived on site for oven fans not shutting down and error code f3e1, found bad control board, replaced control board, unit tested good.
Near Georgetown, TX 78633
Thomas L.
Job Details:
04/26/2018
Near Pflugerville, TX 78660
Nathaniel B.
Job Details:
04/26/2018
Model WFG530S0ES1, Arrived on call for oven not heating properly, found that actual complaint is intermittently will not heat back up, found the bake igniter connection was loose and was backing out so tightened connection and reconnected it fully, retested and was not able to get symptom to repeat.
Near Pflugerville, TX 78660
Nathaniel B.
Job Details:
04/26/2018
Model WFG530S0ES1, Arrived on call for oven not heating properly, found that actual complaint is intermittently will not heat back up, found the bake igniter connection was loose and was backing out so tightened connection and reconnected it fully, retested and was not able to get symptom to repeat.
Near Pflugerville, TX 78660
Nathaniel B.
Job Details:
04/26/2018
Model WFG530S0ES1, Arrived on call for oven not heating properly, found that actual complaint is intermittently will not heat back up, found the bake igniter connection was loose and was backing out so tightened connection and reconnected it fully, retested and was not able to get symptom to repeat.
Near Pflugerville, TX 78660
Nathaniel B.
Job Details:
04/26/2018
Model WFG530S0ES1, Arrived on call for oven not heating properly, found that actual complaint is intermittently will not heat back up, found the bake igniter connection was loose and was backing out so tightened connection and reconnected it fully, retested and was not able to get symptom to repeat.
Near Cedar Park, TX 78613
Lou
Job Details:
04/26/2018
arrived on site to install previously diagnosed and ordered parts. Removed and replaced he UI and control. Tested unit in diagnostic mode and unit operates as designed. No water leaks observed during service.
Near Austin, TX 78738
Brandon
Job Details:
04/26/2018
Arrived on site for Error code on dishwasher f2e2, found faulty UIB was not communicating with Central control board. I replaced UIB unit tested good. Collected 399.47 on cc.
UIB 209.04
Labor Dw135 159.99
Near Pflugerville, TX 78660
Nathaniel B.
Job Details:
04/26/2018
Model WCG97US6DS00, Arrived on call for middle burner is heating but not the way it wAs before, found that power burner orfis had grease in it so cleaned burner head and orfises and checked operation and know flame is fully lit, all checks good, no gas leaks at time of call.no parts needed, call complete.
Near Pflugerville, TX 78660
Nathaniel B.
Job Details:
04/26/2018
Model WCG97US6DS00, Arrived on call for middle burner is heating but not the way it wAs before, found that power burner orfis had grease in it so cleaned burner head and orfises and checked operation and know flame is fully lit, all checks good, no gas leaks at time of call.no parts needed, call complete.
Near Austin, TX 78745
Connor M.
Job Details:
04/26/2018
MGR6775ADW maytag oven Arrived on site to test unit for not baking in lower section. Found glow igniter not coming on. Ingiter tested open. Ordering igniter for return. Jordan approved 5/1
Near Leander, TX 78641
Lou
Job Details:
04/26/2018
arrived on site to inspect refrigerator not dispensing water but is making ice. I checked the dispenser and could hear the valve turning on. I verified that the filter was not the issue of no water. The customer advised that the ice maker made a batch of ice this morning. I verified that the water source was turned on and purged the water to remove any debris and then I removed and replaced the water valve and the unit still did not dispense water. I removed and replaced the water inlet valve and the unit operated as designed. No water leaks observed during service. There were large gaps between the cabinet and inner lining at the bottom of the opening of the rc and fc. I used manufacturer approve silicone and sealed the gaps. Job completed.
Near Austin, TX 78734
Brandon
Job Details:
04/26/2018
Arrived on site for f35 error code, water over filling tub. Checked connections at pressure hose, tested good, tested drain pump, tested good, tested pressure switch, tested good, water valve opened and closed good. Found water around the drain hose in the wall, instructed customer to have the drain pipe cleaned out. Collected service fee.
Near Killeen, TX 76543
Dona
Job Details:
04/26/2018
Arrived on site for no drain on washer, found mechanically broken lid switch, replaced lid switch, verified full drain and spin, filled unit, agitated, drained and spun. All water connections dry.
Near Killeen, TX 76543
Dona
Job Details:
04/26/2018
Arrived on site for no drain condition, found diverted on lower rack had been moved. Reseated and verified full load with all drains working. All water connections dry unit checks good.
Near Manor, TX 78653
Joseph C.
Job Details:
04/26/2018
WED4815EW1 Arrived on site for “clothes not drying” complaint. Inspected unit and found high limit thermostat blown, due to blocked vent line. Removed and replaced thermostat. Unit is performing as designed. Instructed customer to refrain from use until venting has been cleaned. Instructed customer to clean venting every six months to prevent possible fire hazards and for better performance and economy.
Near Austin, TX 78737
Connor M.
Job Details:
04/26/2018
MVWX500XW0 maytag washer Arrived on site to test unit for not spinning water out of clothes. Found when trying to agitate or spin the motor would just hum and basket would not move. Diagnosed bad capacitor. When replacing capacitor found damaged wire on connector. Re did connections and replaced capacitor. Unit working properly, no leaks detected.
Near Manor, TX 78653
Joseph C.
Job Details:
04/26/2018
WRT318FMDM02 Arrived on site for “seal damaged on fresh foods door” complaint. Inspected unit and found gasket out of track. Reinserted gasket and used hair dryer to seat gasket to cabinet frame. No leaks detected, at time of service.
Near Austin, TX 78738
Brandon
Job Details:
04/26/2018
Arrived on site for glass broken on oven, removed broken inner glass, installed new glass, tested good. Collected 269.75 on check
Near Temple, TX 76502
Dona
Job Details:
04/26/2018
Arrived on site for no ice production found stalled ice maker motor. Replaced ice maker assembly. Unit called for water and started ice production, checked temps, fridge is at 36 degrees, freezer at 5 degrees
Near Georgetown, TX 78633
Thomas L.
Job Details:
04/26/2018
Arrived on site for door handle issue. Found that the right Side handle set screw had cracked and handle was no longer securely attached to the front panel. Replaced and tested. All water connections were dry.
Near Round Rock, TX 78665
Mike C.
Job Details:
04/26/2018
Whirlpool microwave WMH31017FS0 Arrived to find interior light flickering when the door is opened. Found door switches and interlocks bad. Installed new door switches and interlocks, checked operation and unit checked good.
Near Austin, TX 78703
Connor M.
Job Details:
04/26/2018
WFW94HEXW2 whirlpool washer Bellow-169.41 FL370-99.99 arrived on site to test unit for leaking during large loads. Removed bellow completely to closely inspect and found to small rips. Replaced bellow and tested unit. Unit working properly, no leaks detected. Collected balance via cc.
Near Temple, TX 76502
Dona
Job Details:
04/26/2018
Arrived on site for unit not going in to spin cycle, worked for a few loads after board replacement then started same problem unit would fill on wash then go straight to drain and shut off, because pressure transducer on board not relaying water height. Replaced control and ran unit through full normal regular cycle with bedding. Unit filled, agitated, rinse, and spun. New control was faulty. All water connections dry. No errors.
Near Georgetown, TX 78633
Thomas L.
Job Details:
04/26/2018
Arrived on site to correct right front not lighting issue. Found that small portion of the right front burner would not light. Found small obstruction in orifice. Corrected and tested. All burners not work properly.
Near Dripping Springs, TX 78620
Brandon
Job Details:
04/26/2018
Arrived on site for washer vibrating during cycle, I leveled the unit the best I could on the tile floor, I recalibrated the unit, tested good. Instructed customer to wash like items with like items.
Near Austin, TX 78703
Connor M.
Job Details:
04/26/2018
JDB1100AWS jennair dishwasher Arrived on site to install parts for repair. Installed sensor and thermostat. Ran unit for 10 minutes to check for proper function and leaks. Unit working properly, no leaks detected. Collected remaining balmce via cc.
Near Leander, TX 78641
Lou
Job Details:
04/26/2018
arrived on site to install previously diagnosed and ordered parts. Removed and replaced the sump/motor and control. Tested unit and unit operated as designed. No water leaks observed during service.
Near Temple, TX 76502
Dona
Job Details:
04/26/2018
Arrived on site for low water in tub, found customer is using options for cycles with less water, instructed customer on operations of unit. Verified with full load of clothing that unit is getting enough water per mfg measurement. All water connections dry. Unit running to spec.
Near Temple, TX 76502
Dona
Job Details:
04/26/2018
Arrived on site for not heating properly, found customer is using sensor dry and washing mixed loads, explained timed dry functions and sensor dry functions, checked that ducting is clear and temperature and airflow are good. All operations check to mfg spec.
Near New Braunfels, TX 78130
Daniel A.
Job Details:
04/26/2018
WMH31017FB Microwave not closing/latching. Defective interlock/switch assemblies. Replaced upper lower interlock switches/interlocks Tested unit working normal. Switches shorted fuse. Replaced fuse
Near Liberty Hill, TX 78642
Thomas L.
Job Details:
04/26/2018
Arrived on site for poor drying conditions and odors. Tested operations which were all normal. Heater did energize and sizzle water. Incoming water to unit was 107 degrees. Unit has no drying agent in dispenser. Water connections were dry.
Near Leander, TX 78641
Lou
Job Details:
04/26/2018
arrived on site to inspect refrigerator light not working and a broken shelf. Upon further inspection, I found that the light is fine, but the light switch is sticking keeping the light from coming on. Quoted the customer $39.83 for to replace the shelf and customer agreed to cost and paid. Office to order light switch and scheduled return service for 05/01/18 MS. No water leaks observed during service.
Near New Braunfels, TX 78132
Connor M.
Job Details:
04/26/2018
WRS588FIHZ00 whirlpool refrigerator Arrived on site to test unit for no ice production. Found clogged filltube, and bad icemaker. Unclogged fill tube and replaced icemaker. Facia heater failed, also clips that hold ice maker in place the left one is slightly recessed. Will need to order door for return. Office to schedule directly.
Near Morgan's Point Resort, TX 76513
Dona
Job Details:
04/26/2018
Arrived on site for no drain condition, found unit is draining but not spinning clothes leaving excess water. Replaced actuator due to not engaging on spin cycle. Re calibrated, ran through short cycle. All water connections dry, unit is spinning. All operations checked good.
Near Austin, TX 78759
Luis
Job Details:
04/26/2018
Refrigerator-replaced mullion divider
Near Georgetown, TX 78633
Mike C.
Job Details:
04/26/2018
Whirlpool Refrigerator WRS325FDAW01 Arrived to install new ice container. Checked operation and unit checks good.
Near Seguin, TX 78155
Kevin
Job Details:
04/26/2018
EV250NXTQ02 Arrived on site and found Frost has dissipated, added silicon in between inner liner and counter cabinet in order to assist with freezer seal. No water leaks from connections at time of service
Near Georgetown, TX 78626
Thomas L.
Job Details:
04/26/2018
Arrived on site for sparking during operation. Tested unit and found no problems. Discussed with customer that if the bilevel rack touches the wall it makes a metal to metal situation which will cause sparking. Customer informed me that since that rack was taken out the unit has never spark since. Operations are normal.
Near New Braunfels, TX 78130
Connor M.
Job Details:
04/25/2018
MVWX655DW1 maytag washer Arrived on site to test unit for shaking violently during spin even when empty. Found basket has small amount of play likely indicating bent chaft on gearcase. Unable to confirm is gearcase or basket is bad. On return both parts need to be replaced. Will need two hours. Office to schedule directly.
Near Leander, TX 78641
Lou
Job Details:
04/25/2018
arrived on site to inspect dishwasher not operating. Upon inspection, I placed the unit in diagnostic mode and found an F8E2 error code. Ran the unit in diagnostic mode and found that the drain pump would not engage so I verified the connection. Office to order drain pump and schedule return service for 05/01/18 MS. I will return with pre diagnosed control and UI on next service. No water leaks observed during service.
Near Leander, TX 78641
Jerry C.
Job Details:
04/25/2018
WMH31017FS0 Arrived to instal previously diagnosed and ordered parts. I removed and replaced the control and all three switches and mounts. I removed and replaced the door. I found the front of the chassis bent inward and I corrected it. Operational test good.
Near Austin, TX 78734
Luis
Job Details:
04/25/2018
Ice machine-installed new external drain pump
Near Canyon Lake, TX 78132
Connor M.
Job Details:
04/25/2018
WRX735SDBM whirlpool refrigerator Arrived on site to test unit for no ice production. Found icemaker continuously rotating when forced into harvest mode. Replaced icemaker. Unit did not cycle with door closed. Found surface on door that strikes switch is warped. Door will need to be replaced. Pic attached to quick pics. Added temporary spacer to allow ice production. Office to schedule directly.
Near Cedar Park, TX 78613
Lou
Job Details:
04/25/2018
arrived on site to install previously diagnosed and ordered parts. Removed and replaced the oven door outer glass and handle. Tested unit and unit tested good. Job completed.
Near Killeen, TX 76549
Dona
Job Details:
04/25/2018
Arrived on site for no operation, found open thermal fuse. Replaced, unit is running to spec, verified clear ducting, timer advancing, not sticking on heater relay. Good airflow. Unit checks good.
Near Kingsland, TX 78639
Thomas L.
Job Details:
04/25/2018
Arrived on site for no fill condition. Customer explained the unit would fill but would not fill enough. Found unit to,be working properly.
Near Killeen, TX 76549
Dona
Job Details:
04/25/2018
Arrived on site for drawer freezing on evaporator cover, found damper not opening upon testing, will replace evap fan with wiring upon return. Ordered cover and mullion in case of brittleness. Discussed with customer that they will turn unit off to defrost for return. Discussed using towels. All water connections dry
Near Austin, TX 78746
Luis
Job Details:
04/25/2018
Refrigerator-replaced diffuser assembly
Near Round Rock, TX 78664
Nathaniel B.
Job Details:
04/25/2018
Model ED5GHEXNL00, Arrived on call for loud noise from unit, found condenser fan motor is bad and fan blade is warped due to shaft is loose in motor and kept hitting fan mounting, will order condenser fan motor and blade, instructed customer to turn unit off and put all food in to coolers so if condenser fan motor fails when she is not home will posably loose food and cause further damage, Skyped office parts and talked to jordan and will reschedule for 4/30/18
Near Round Rock, TX 78664
Nathaniel B.
Job Details:
04/25/2018
Model ED5GHEXNL00, Arrived on call for loud noise from unit, found condenser fan motor is bad and fan blade is warped due to shaft is loose in motor and kept hitting fan mounting, will order condenser fan motor and blade, instructed customer to turn unit off and put all food in to coolers so if condenser fan motor fails when she is not home will posably loose food and cause further damage, Skyped office parts and talked to jordan and will reschedule for 4/30/18
Near Marble Falls, TX 78654
Thomas L.
Job Details:
04/25/2018
Arrived on site for no spin condition. Tested unit and found unit would not spin or drain. Remove drain pipe and found that it’s impeller was biting against it’s own housing. Corrected situation and tested. All operations were normal and dry.
Near Leander, TX 78641
Lou
Job Details:
04/25/2018
arrived on site to inspect dishwasher asking a grinding noise. I placed the unit in diagnostic mode and received error codes 6/4, 5/1, 9/1, and 5/2. The unit would not fill with water and while attempting to fill, the motor was making a grinding noise. I tested the drain and it tested good. I removed and replaced the sump/motor, tested unit and unit operates as designed. No water leaks observed during service.
Near New Braunfels, TX 78132
Daniel A.
Job Details:
04/25/2018
WOS51EC0AS03 Control panel not coming on. Defective thermal fuse. Replaced fuse. Blower not operating. Corrected blower wire connections. Verified normal operation after service
Near Austin, TX 78745
Robert
Job Details:
04/25/2018
MAH6500AW2 Maytag washer noise
Near Marble Falls, TX 78654
Thomas L.
Job Details:
04/25/2018
Arrived on site for improper door operation. Fresh food section door was loose and not closing properly due to hinge scores were not secure. Corrected middle hinge screw situation and door now operates properly.
Near Austin, TX 78749
Robert
Job Details:
04/25/2018
WTW5000DW0 Whirlpool washer leaking
Near Austin, TX 78704
Robert
Job Details:
04/25/2018
Near Leander, TX 78641
Lou
Job Details:
04/25/2018
arrived on site for to inspect microwave door not closing. Upon further inspection, I found that the light stays on when the unit is operating as if the door was open. I pushed on the door and the light turned off. Due to this unit being an oven/microwave wall unit, I had to removed the oven to replace the interlocks. Removed and replaced both interlocks, tested unit and unit operates as designed. Job completed.
Near Temple, TX 76501
Mike G.
Job Details:
04/25/2018
MEDB835DC4, Arrived on site for unit taking to long to dry checked unit and found that the unit has good air flow and unit is heating checked unit and found that the the dryness level is at 2 reajusted dryness level to 3 15% more checked unit and unit checked fine at this time... checked and cleaned out all lent found from unit....
Near Temple, TX 76501
Mike G.
Job Details:
04/25/2018
MEDB835DC4, Arrived on site for unit taking to long to dry checked unit and found that the unit has good air flow and unit is heating checked unit and found that the the dryness level is at 2 reajusted dryness level to 3 15% more checked unit and unit checked fine at this time... checked and cleaned out all lent found from unit....
Near Dripping Springs, TX 78620
Brandon
Job Details:
04/25/2018
Arrived on site for part hanger, I replaced all parts, unit tested good.
Near Austin, TX 78745
Luis
Job Details:
04/25/2018
Refrigerator-repaired light switch remolded fresh food door seal
Near Marble Falls, TX 78654
Thomas L.
Job Details:
04/25/2018
Arrived on site for no light operation. Found the freezer door was not depressing switch properly to turn on light. Adjusted door and operations are now normal. Water connections are dry.
Near Austin, TX 78704
Robert
Job Details:
04/25/2018
Kgsa906pss00 gas range control
Near Harker Heights, TX 76548
Dona
Job Details:
04/25/2018
Arrived on site for fridge not cooling below 55 degrees, found unit is completely frosted over, ran test for fans found condenser fan not turning on. Will need condenser fan. Will replace evap cover and condenser fan on return. May need control. Sarah assisted with reschedule and part. All water connections dry. Customer will defrost unit before tech returns. Discussed towels and defrost procedure.
Near Austin, TX 78744
Luis
Job Details:
04/25/2018
Refrigerator-replaced diffuser and defrosted water tank
Near Round Rock, TX 78664
Mike C.
Job Details:
04/25/2018
Whirlpool Microwave WMH73521CS6 Arrived to find unit not always starting a cycle and saying open/close door in the display. Found door switches and interlocks bad. Installed new door switches and interlocks, checked operation and unit checked good.
Near Temple, TX 76502
Mike G.
Job Details:
04/25/2018
WDF520PADM7, Arrived on site for unit will turn off in med cycle, checked unit and found no error codes and found when vent fan starts unit will turn off unit will need vent assy and gasket checked unit for water leaks and no leaks found at tim of srv... ordering part per JA r/s next apt for 4/27/18 customer is not able to be home for srv on 4/27/18 and is wanting next apt for 5/2/18
Near Temple, TX 76502
Mike G.
Job Details:
04/25/2018
WDF520PADM7, Arrived on site for unit will turn off in med cycle, checked unit and found no error codes and found when vent fan starts unit will turn off unit will need vent assy and gasket checked unit for water leaks and no leaks found at tim of srv... ordering part per JA r/s next apt for 4/27/18 customer is not able to be home for srv on 4/27/18 and is wanting next apt for 5/2/18
Near Liberty Hill, TX 78642
Steve C.
Job Details:
04/25/2018
Arrived on site for the unit control panel started to smoke. Removed the control panel and found the control has shorted and melted. Called Whirlpool
Sr#7721824192 Andrew and advise safety will contact customer. All water connections were dry at the time of service.
Near Marble Falls, TX 78654
Thomas L.
Job Details:
04/25/2018
Arrived on site for improper operations. Tested all functions and all working properly. There were no water leaks. Instructed customer to let us know if any other issues arise.
Near Temple, TX 76502
Mike G.
Job Details:
04/25/2018
WED5000DW2, Arrived on site for unit take to long to dry, checked unit air flow with vent hose hooked up and unit has very week air flow removed vent hose from unit and unit has good air flow found that the customer will need vent from the wall going out side cleaned out, checked nd cleaned out all lent found from unit, unit checked fine at this time.....
Near Temple, TX 76502
Mike G.
Job Details:
04/25/2018
WED5000DW2, Arrived on site for unit take to long to dry, checked unit air flow with vent hose hooked up and unit has very week air flow removed vent hose from unit and unit has good air flow found that the customer will need vent from the wall going out side cleaned out, checked nd cleaned out all lent found from unit, unit checked fine at this time.....
Near Temple, TX 76502
Mike G.
Job Details:
04/25/2018
WED5700VW0, Arrived on site to install new timer checked and cleaned out all lent found from unit and tested unit after repair and unit is heating and has good air flow unit checked fine at this time....
Near Temple, TX 76502
Mike G.
Job Details:
04/25/2018
WED5700VW0, Arrived on site to install new timer checked and cleaned out all lent found from unit and tested unit after repair and unit is heating and has good air flow unit checked fine at this time....
Near Austin, TX 78739
Brandon
Job Details:
04/24/2018
Arrived on site for part hanger, I replaced adjuster and leveled the unit, everything tested good. Collected 129.89 on check.
Near Leander, TX 78641
Lou
Job Details:
04/24/2018
arrived on site to inspect noisy dryer. Upon inspection, I turned the drum and found that the unit was making an extremely loud metal to metal grinding noise. I removed the top of the unit and found that the control bracket was missing a screw and it was resting on the outer portion of the drum and was causing the grinding sound. I replaced the screw and set the bracket back in place and tested the unit and the unit operates as designed. No lint observed during service.
Near Liberty Hill, TX 78642
Thomas L.
Job Details:
04/24/2018
Arrived on site for Noisey operation and no cool condition. Turned breaker back on to power up unit. All operations started up now normal. All water connections were dry.
Near Austin, TX 78739
Brandon
Job Details:
04/24/2018
Near Hutto, TX 78634
Nathaniel B.
Job Details:
04/24/2018
Model GX5FHDXVY04, Arrived on call for improper temps in unit, previously found evap fan running while unit was in defrost, found only top half of the freezer evap coil built with ice which is a indication of incomplete defrost, called whirlpool tech line and talked to kevin file number 7721820855, freezer sensor reads 13.7 k ohms at 60 degrees which is with in range, checked fresh food sensor and was out of range replaced control and fresh food sensor harness freezer sensor harness not needed and programed control, and instructed customer to allow for 24-48 hours for proper cooling, no water leaks at time of call, call complete.
Near Hutto, TX 78634
Nathaniel B.
Job Details:
04/24/2018
Model GX5FHDXVY04, Arrived on call for improper temps in unit, previously found evap fan running while unit was in defrost, found only top half of the freezer evap coil built with ice which is a indication of incomplete defrost, called whirlpool tech line and talked to kevin file number 7721820855, freezer sensor reads 13.7 k ohms at 60 degrees which is with in range, checked fresh food sensor and was out of range replaced control and fresh food sensor harness freezer sensor harness not needed and programed control, and instructed customer to allow for 24-48 hours for proper cooling, no water leaks at time of call, call complete.
Near Leander, TX 78641
Lou
Job Details:
04/24/2018
arrived on site to install previously diagnosed and ordered parts. Removed and replaced the outer door glass and door gasket. Installed an installation strip as advised in a service pointer. Tested unit and unit tested good. Advised customer of my work. No gas leaks detected during service.
Near Waco, TX 76710
Mike G.
Job Details:
04/24/2018
MGR8700DS3, Arrived on site for broiler not working checked unit and found that the broiler ignitor is not Sparking replaced broiler ignitor checked unit and found that the broiler is now now lighting checked unit for gas leaks and no leaks found at time of srv... unit checked fine at this time....
Near Waco, TX 76710
Mike G.
Job Details:
04/24/2018
MGR8700DS3, Arrived on site for broiler not working checked unit and found that the broiler ignitor is not Sparking replaced broiler ignitor checked unit and found that the broiler is now now lighting checked unit for gas leaks and no leaks found at time of srv... unit checked fine at this time....
Near Georgetown, TX 78633
Mike C.
Job Details:
04/24/2018
Whirlpool microwave WMH32517AS1 Arrived to check unit for not heating. Found 122 volts at high voltage transformer input side. Found capacitor and diode have shorted out the magnetron. Installed new capacitor, diode and magnetron, checked operation and unit checks good.
MW140 $159.99 - Magnetron $149.97 - Capacitor $67.65 - Diode $45.64
Near Belton, TX 76513
Dona
Job Details:
04/24/2018
Arrived on site for knocking noise, found hot and cold water hoses swapped on back of unit, when valve turning on and off hoses hitting back of machine. All parms checked good, all water connections dry. Customer will swap hot and cold. Customer needed to pick up kids. No abnormal noises no errors. All operations normal.
Near Horseshoe Bay, TX 78657
Thomas L.
Job Details:
04/24/2018
Arrived on site for inspection of unit that caught on fire. Found that the entire control panel area was charred from fire that happened in left side of the control board. Control panel 4451063 is discontinued. Main control board 4448869 is discontinued. The entire wire harness for both units would have to be replaced. Due to heat it appears that the wave guide got damaged and that is not a replaceable part. My opinion is that this unit is not repairable and I would be afraid that every electrical component in both unit would have to also be replaced as it is still not for certain which part caused fire. This unit also caught house cabinet on fire as well. The customer has expressed that they could never trust this unit again.