Near Liberty Hill, TX 78642
Thomas L.
Job Details: 08/18/2018
Arrived on site for Noisey operation. Found drain pan is vibrating against bottom of the cabinet. More sealer is needed to insulate and stop noise.
Near Georgetown, TX 78626
Lou
Job Details: 08/18/2018
arrived on site to inspect washer leaking water. Upon arrival, the customer advised that he found a puddle of water after the washer had finished a cycle. Customer advised he looked the unit over and could not find anything. Upon further inspection, I placed the unit in diagnostics to test and the were no error codes so I continued with testing. Looking around the unit, I found no evidence of water leaks on the outer panels of the unit nor on the floor. At the end of testing, the were no error codes. I opened the top of the unit and looked around the outer tub and found no evidence of water leakage. I secured the top and lifted the unit and checked underneath the unit and found no evidence of water leaks. I took photos of the areas where the customer found the puddle of water and of the drain pump/hose to show the customer my findings. No water leaks observed during service. Job completed. I advised the customer that should the issue occur again to take pictures and contact Whirlpool t
Near Austin, TX 78730
Scott
Job Details: 08/18/2018
Replaced control panel . Jenn air wall oven
Near Round Rock, TX 78665
Lou
Job Details: 08/18/2018
arrived on site to inspect dryer making loud noise. Upon arrival, the customer advised that the unit is making a loud screeching noise and it has a burning smell and is not heating well. I turned the unit on and immediately the unit began to make the screeching noise and I could smell something burning. I opened the unit up to inspect further and found that the heating element was burnt out and there was burnt no around the element. Due to the unit being a steam dryer, I advised the customer that they would need to contact someone to come out and clean their vents and dryer ducts. Also, I found that there was debris on the rollers causing them to make the screeching noise. I removed and replaced the element and dryer kit and tested the unit. The unit operates as designed. No lint observed during service, job complete.
Near Austin, TX 78731
Scott
Job Details: 08/18/2018
Amanda top load washer
Near Georgetown, TX 78633
Thomas L.
Job Details: 08/18/2018
Arrived on site for Noisey operation. Found top half of agitator is causing the noise. Replaced. All water connections were dry.
Near Jarrell, TX 76537
Thomas L.
Job Details: 08/18/2018
Arrived on site or water leaking. Inspected unit and found that the main inlet hose that goes from the valve to the dispenser is split and leaking left unit unplugged. Office to locate part and reschedule with customer.
Near Round Rock, TX 78665
Lou
Job Details: 08/18/2018
arrived on site to inspect dishwasher dispenser not working. Upon further inspection, I found that the unit dispenser had too much soap residue around the edges that was keeping the door from locking/unlocking. I removed and replaced the dispenser and tested the unit and the unit operated as designed. No water leaks observed during service, job completed.
Near Driftwood, TX 78619
Kevin
Job Details: 08/17/2018
Arrived on site and inspected refrigerator and found currently dispenser flow is good. Customer is experiencing no water dispensing but UI is still counting ounces, problem is intermittent. Spoke with the tech line and they recommended adding in line pressure regulator to correct issue. No water leaks from connections at time of service.
Near Pflugerville, TX 78660
Wesley
Job Details: 08/17/2018
NED4655EW1 arrived on site and found unit breaker tripped. Corrected breaker and advised customer on use and care. All checks good. Unit operating as designed.
Near Driftwood, TX 78619
Kevin
Job Details: 08/17/2018
Arrived on site and found ice auger is not turning, removed motor and found it is rusted and frozen. Took one picture. Shaft and top connector will need to be replaced as well due to age. No water leaks from connections at time of survey was
Near Taylor, TX 76574
Nathaniel B.
Job Details: 08/17/2018
Model KUDE48FXSS5, Arrived on call for dishwasher has no operation, 8-4 which is drain motor electrical problem, 9-1 diverter can not find position, , found drain pump had piece of glass in it which was not allowing to drain and was causing diverter to stick, diverter is working as it should, only charged customer service fee of 99.99 plus tax which = 108.24, no water leaks at time of service. Also gave customer instructions on soap and rinse aid use due to over soaping.
Near Taylor, TX 76574
Nathaniel B.
Job Details: 08/17/2018
Model KUDE48FXSS5, Arrived on call for dishwasher has no operation, 8-4 which is drain motor electrical problem, 9-1 diverter can not find position, , found drain pump had piece of glass in it which was not allowing to drain and was causing diverter to stick, diverter is working as it should, only charged customer service fee of 99.99 plus tax which = 108.24, no water leaks at time of service. Also gave customer instructions on soap and rinse aid use due to over soaping.
Near Dripping Springs, TX 78620
Kevin
Job Details: 08/17/2018
Arrived on site and inspected dishwasher and found no water during the wash cycle. Found no water at source and after correcting all function has returned to dishwasher. The water leaks from connections at time of service, job complete.
Near Austin, TX 78731
Cliff
Job Details: 08/17/2018
Whirlpool refrigerator WRX986SIHZ00. Arrived on site to diagnose a refrigerator with lights that are not operating. Tested unit and found LEDs only operational after a hard reset on control board. This indicates fill the timer circuit in LED control. Replaced LED control and tested unit. Found all is functioning properly at this time. No leaks were found at time of service.
Near Austin, TX 78717
Tyler B.
Job Details: 08/17/2018
Near Belton, TX 76513
Dona
Job Details: 08/17/2018
Arrived on site for door falling apart, unit will need a new door assembly, part is showing up as NLA on marcone and servall WB56X10480. Unit will also need new choke for door if not included on new door. Units exterior light is burned out not interior light customer would need to pay for this light bulb. Will need authorization and part found. Unit is still functioning.
Near Taylor, TX 76574
Nathaniel B.
Job Details: 08/17/2018
Model WDT780SAEM1, Arrived on call for dispenser broken and console is warped, installed both parts and tested and all checks good, no leaks after repair, call complete.
Near Taylor, TX 76574
Nathaniel B.
Job Details: 08/17/2018
Model WDT780SAEM1, Arrived on call for dispenser broken and console is warped, installed both parts and tested and all checks good, no leaks after repair, call complete.
Near Taylor, TX 76574
Nathaniel B.
Job Details: 08/17/2018
Model WDT780SAEM1, Arrived on call for dispenser broken and console is warped, installed both parts and tested and all checks good, no leaks after repair, call complete.
Near Taylor, TX 76574
Nathaniel B.
Job Details: 08/17/2018
Model WDT780SAEM1, Arrived on call for dispenser broken and console is warped, installed both parts and tested and all checks good, no leaks after repair, call complete.
Near Horseshoe Bay, TX 78657
Thomas L.
Job Details: 08/17/2018
Entered home the garage code provided by customer. Replaced inlet water,valve. Loaded reservoir with customers cleaner and scrubbed unit. Started clean cycle for customer. All water connections were dry. Left garage and closed door.
Near Liberty Hill, TX 78642
Lou
Job Details: 08/17/2018
arrived on site to inspect dishwasher not completing cycles. Upon further inspection, implanted the unit in diagnostics and checked for error codes and there were none. I continued with testing and the unit operated as designed with no error codes at the end of testing. I cannot find anything mechanically wrong with this unit. I quoted the customer DW100 $99.99 and with tax the total was $108.24. The customer paid in full. No water leaks observed during service, job completed.
Near Belton, TX 76513
Dona
Job Details: 08/17/2018
Arrived on site for broken knob, discussed with SC knob not covered per David with warrantech. Customer bout knob. 44.91 tax 3.71 total 48.62.customer paid with card. Will need to charge warrantech for service call. All operations check good.
Near Hutto, TX 78634
Nathaniel B.
Job Details: 08/17/2018
Model WTW4616FW1, Unit is still under the Aaron’s extended warrantyArrived on call for washer fills with water but will not agitate, checked for error codes and got f8 e1 long fill no fill which was the only error, found when running cold water on auto test barley got a trickle of water and a reduction on hot water it still should be filling faster, unit will need water valve, did run auto test and all other functions checked good, installed water valve and tested and all checks good, customer had to shut off water to the home to disconnect water line fill hoses from the home due to one of the shut offs does not shut off at the wall, customer to contact a plumber , no errors after repair after filling the machine, call complete. No water leaks at time of call.
Near Hutto, TX 78634
Nathaniel B.
Job Details: 08/17/2018
Model WTW4616FW1, Unit is still under the Aaron’s extended warrantyArrived on call for washer fills with water but will not agitate, checked for error codes and got f8 e1 long fill no fill which was the only error, found when running cold water on auto test barley got a trickle of water and a reduction on hot water it still should be filling faster, unit will need water valve, did run auto test and all other functions checked good, installed water valve and tested and all checks good, customer had to shut off water to the home to disconnect water line fill hoses from the home due to one of the shut offs does not shut off at the wall, customer to contact a plumber , no errors after repair after filling the machine, call complete. No water leaks at time of call.
Near Horseshoe Bay, TX 78657
Thomas L.
Job Details: 08/17/2018
Arrived on site for no ice condition. In diagnostics all operations worked however the water valve is very weak. Will order valve.
Near Belton, TX 76513
Dona
Job Details: 08/17/2018
Arrived on site for unit not turning on, found control not sending proper supply. Replaced control, verified ops unit checks good. Ducting clear.
Near Belton, TX 76513
Dona
Job Details: 08/17/2018
Arrived on site to install lid switch, in between last tech visit lid switch had completely failed. Replaced lid switch verified operations, unit filled, agitates, spins and drains. All operations check good. All water connections dry. Customer had previously paid 108.24. TL330-179.99 and part $40.65 tax 18.20 total remaining balance was $130.60. Collected 130.60 on card.
Near Liberty Hill, TX 78642
Lou
Job Details: 08/17/2018
arrived on site to inspect dishwasher not working. Upon further inspection, I placed the unit in diagnostics to test and it showed error codes 7/1, 6/6, 8/2. I cleared the codes and continued with testing. I find that the motor was not coming on, but I could hear the diverter working. I removed and replaced the sump/motor assembly and tested the unit and the unit operated as designed. No water leaks observed during service, job completed.
Near Round Rock, TX 78665
Tyler B.
Job Details: 08/17/2018
Near Round Rock, TX 78665
Tyler B.
Job Details: 08/17/2018
Near Austin, TX 78732
Paul
Job Details: 08/17/2018
KitchenAid Ice Machine Model KUIX305ESS1. Arrived onsite for the ice machine that is leaking water from the back. I found the machine had been moved and the drain line had come out of the wall pipe. Ms stated she pulled it out when she noticed there was a leak. This ice machine is on a gravity drain and the house drain pipe comes out of the wall behind the washer drain and has an elbow that is turned up with the ice machine drain tube hanging down and entering it. It appears that the machine had been pulled forward just enough to cause the drain tube to partially come out. I put the drain tube back in the PVC wall pipe and tested the unit. There were no water leaks present at the time of service. Call complete.
Near Leander, TX 78641
Lou
Job Details: 08/17/2018
arrived on site to inspect dishwasher upper rack falling. Upon further inspection, I found that the upper rack stops were popping off and were not properly secured. Both stops locks were worn and would not latch securely. I removed and replaced both stops and tested the unit. The unit operated as designed, no water leaks observed during service. Job completed.
Near Marble Falls, TX 78654
Thomas L.
Job Details: 08/17/2018
Arrived on property. Customer opened garage via phone. Entered and found Noisey operation coming from loose condenser fan motor bracket screw. Tightened. Operation now normal and water connections were dry. Exited via garage and door did close.
Near Round Rock, TX 78665
Tyler B.
Job Details: 08/17/2018
Near New Braunfels, TX 78132
Daniel A.
Job Details: 08/17/2018
KSSS42QJB00 built in refrigerator not cooling/freezing. Sealed system overhaul. Replaced compressor/heat exchanger/evaporator and Pan heater. Verified no air/water/refrigerant leaks. Normal operation after service
Near Leander, TX 78641
Lou
Job Details: 08/17/2018
arrived on site to inspect coin operated washer not coming on. Upon further inspection, I had the maintenance personnel open up the coin expose the timer. I found that when the coin slide is pushed in it is not engaging with the timer to start the wash. I found that the metal extender is going above the metal timer bracket to the left of extended slide just above the timer was bent down and not allowing the slide to engage the timer. I adjusted the timer bracket and tested the slide and it is now engaging with the timer and the washer is coming on as designed. I quoted the customer TL100 $99.99 for a total including tax of $108.24. The customer paid in full. No water leaks observed during service, job completed.
Near Hutto, TX 78634
Nathaniel B.
Job Details: 08/17/2018
Model GTS18JCPWRBB, Brown color water dripping from light in fridge, found for moisture around light in fresh food the control housing js warped will order housing control and nozzle control due to warped on top of fresh food leaking air, also found for leaking brown and yellow substance from front of fridge the substance is from over time things running down were inside liner meets outer cabinet over time and with moisture running down in it it is leaking on to floor, will need to seal were inside liner meets outer cabinet with silicone and also found bottom of the fresh food door gasket is damaged will need black fresh food door gasket, will reschedule for 8/23/18, no water leaks at time of call. Customer requests a 8-10 am appointment and did instruct customer the time frame is not a guarantee that they will get that time frame. No water leaks at time of call.
Near Hutto, TX 78634
Nathaniel B.
Job Details: 08/17/2018
Model GTS18JCPWRBB, Brown color water dripping from light in fridge, found for moisture around light in fresh food the control housing js warped will order housing control and nozzle control due to warped on top of fresh food leaking air, also found for leaking brown and yellow substance from front of fridge the substance is from over time things running down were inside liner meets outer cabinet over time and with moisture running down in it it is leaking on to floor, will need to seal were inside liner meets outer cabinet with silicone and also found bottom of the fresh food door gasket is damaged will need black fresh food door gasket, will reschedule for 8/23/18, no water leaks at time of call. Customer requests a 8-10 am appointment and did instruct customer the time frame is not a guarantee that they will get that time frame. No water leaks at time of call.
Near Round Rock, TX 78664
Tyler B.
Job Details: 08/17/2018
Near Georgetown, TX 78628
Dona
Job Details: 08/17/2018
Arrived on site for long preheat times and unit not getting to temp ever. Found left side of broil element wiring not attached. Had to remove oven out of wall to put wiring back on. Once wiring was attached, preheated unit and found that unit is now preheating and functioning properly. All operations check good.
Near Round Rock, TX 78665
Nathaniel B.
Job Details: 08/17/2018
Model WDF520PADB7, 1/23/18 is the goods issue date, Arrived on call for water dripping from under dishwasher, called whirlpools tech line and talked to bruce file number 7722734665, will order inner door panel due to break in inner door panel see pic, no water leaks at time of call. Will reschedule for 8/21/18.
Near Round Rock, TX 78665
Nathaniel B.
Job Details: 08/17/2018
Model WDF520PADB7, 1/23/18 is the goods issue date, Arrived on call for water dripping from under dishwasher, called whirlpools tech line and talked to bruce file number 7722734665, will order inner door panel due to break in inner door panel see pic, no water leaks at time of call. Will reschedule for 8/21/18.
Near Austin, TX 78732
Paul
Job Details: 08/17/2018
KitchenAid Refrigerator Model KBSN602ESS01. Arrived onsite for the refrigerator with the FC door popping open and not closing back when the RC door is closed. I found the vacuum release stuck because of a piece of foam. I cleaned it out and tested the doors. The FC door still moves a little when the RC door is closed but it reseals itself. There were no water leaks present at the time of service. Call complete.
Near Georgetown, TX 78626
Thomas L.
Job Details: 08/17/2018
Arrived on site for no cool condition. Found unit to have a leak in fresh food evaporator. Replaced and unit is now operating properly. No water leaks at this time. Customer will need to allow approximately 24 hours for unit to reach maximum cooling temperatures.
Near Austin, TX 78746
Luis
Job Details: 08/17/2018
Icemachine-removed accessible components cleaned ice machine
Near Georgetown, TX 78626
Thomas L.
Job Details: 08/17/2018
Arrived on site for no cool condition. Found unit to have a leak in fresh food evaporator. Replaced and unit is now operating properly. No water leaks at this time. Customer will need to allow approximately 24 hours for unit to reach maximum cooling temperatures.
Near Leander, TX 78641
Lou
Job Details: 08/17/2018
arrived on site to inspect oven door dented. Upon further inspection, I found two small dents in the upper oven door. I removed the door from the unit and removed and replaced the outer door and retuned it back to the unit. Job completed. I contacted the builder to advise of the completion as he was not available to sign the receipt. Job completed.
Near Georgetown, TX 78633
Dona
Job Details: 08/17/2018
Arrived on site for melting inside unit, found wave guide with center starting to melt due to grease on unit Replaced waveguide, also found lower light bulb burned out. Replaced lower bulb, when going to shut bulb off found that control is sending constant voltage to bulb. Will need to replace main control. Removed bulb so that unit would not burn out before return visit. Will return on 8/21/18. All other operations check correctly on unit.
Near Georgetown, TX 78626
Tyler B.
Job Details: 08/17/2018
Near Buda, TX 78610
Robert
Job Details: 08/17/2018
WRB322DMBM00 Arrived on job for complaints of freezing and frost on vent in refrigerator. Confirmed frost on vent . Replaced control and programmed to 01 code. No leaks detected at time of service. Job complete
Near Georgetown, TX 78628
Lou
Job Details: 08/17/2018
arrived on site to inspect washer leaking from underneath and at the water valve. Upon further inspection, I found that the water valve was the main cause for the leaking water. I advised the customer of my findings then removed and replaced the water valve and tested the unit. Unit operated as designed. No water leaks after repair completed. Job completed.
Near San Marcos, TX 78666
Diego G.
Job Details: 08/16/2018
Arrived on site. Check for gasket issues. Found gasket broken not allowing heat to escape in oven. Replaced gasket and cycled oven, all functions tested OK. No leaks present. Job complete
Near San Marcos, TX 78666
Diego G.
Job Details: 08/16/2018
Arrived on site. Check for gasket issues. Found gasket broken not allowing heat to escape in oven. Replaced gasket and cycled oven, all functions tested OK. No leaks present. Job complete
Near San Marcos, TX 78666
Diego G.
Job Details: 08/16/2018
Arrived on site. Check for gasket issues. Found gasket broken not allowing heat to escape in oven. Replaced gasket and cycled oven, all functions tested OK. No leaks present. Job complete
Near Volente, TX 78641
Lou
Job Details: 08/16/2018
arrived on site to inspect refrigerator ice maker not producing enough ice. Upon further inspection, using a cup I tested the water dispenser and water dispensed. I verified that there was ice in the bin. I placed the unit in diagnostics and tested the following modes...1, 2, 3, 4, 5, 15, 19, 36, 37, 45, 56, 57, 58, and 59 and the ice maker tested good. The customer advised that the ice maker had just ripped a batch of ice just before my arrival. I advised the customer test the unit is testing good and there is nothing wrong with the unit. I leveled the unit before leaving. No water leaks observed during service, job completed.
Near Austin, TX 78725
Robert
Job Details: 08/16/2018
WED5000DW2 Arrived on job for complaints of not heating. Found the thermal cut off open. Replaced and test air flow and heating. Both good.
Near Hewitt, TX 76643
Arthur B.
Job Details: 08/16/2018
WRF555SDHV01 (French Door Refrigerator) - Arrived onsite for customer complaint of French door refrigerator not making ice. When arrived,found icemaker was set to off according to UI display. Attempted to turn icemaker on with UI and found UI would not allowing entry. Also found temperature setting will not allow change as well. Ordering UI and returning with icemaker. R/S for Thursday 8/23. All water connections were dry at time of service.
Near Leander, TX 78641
Lou
Job Details: 08/16/2018
arrived on site to inspect range cooktop burners not working. Upon further inspection, I found that the back left burner was not igniting correctly as the spark would only spark in one place and not jump around as designed. Also, I found that the right front Ignitor is doing the same thing. I removed and replaced the back left burner head and tested and it operated as designed. I am ordering a burner head for the right front amid scheduled return service for 08/24/28. Customer advised that she might have something scheduled already, but will contact the office if she needs to reschedule. No gas leaks detected during service.
Near San Marcos, TX 78666
Diego G.
Job Details: 08/16/2018
Arrived on site. Replaced to feed and spinner. Cycled dishwasher, all functions tested OK. No leaks present. Job complete
Near San Marcos, TX 78666
Diego G.
Job Details: 08/16/2018
Arrived on site. Replaced to feed and spinner. Cycled dishwasher, all functions tested OK. No leaks present. Job complete
Near San Marcos, TX 78666
Diego G.
Job Details: 08/16/2018
Arrived on site. Replaced to feed and spinner. Cycled dishwasher, all functions tested OK. No leaks present. Job complete
Near Waco, TX 76712
Arthur B.
Job Details: 08/16/2018
JB755EJ1ES (Freestanding Range) - Arrived onsite for customer complaint of freestanding range getting error code F20 error. Tested broil function and found error code with happen as soon unit attempts to turn on. Found relay not clicking closing to activate broil feature. Unit will need new control and broil element. Advised customer that control is not available. N.E.W will be in contact with customer regarding further steps.
Near Georgetown, TX 78633
Dona
Job Details: 08/16/2018
Arrived on site for no functionality, customer stated they went to use unit and microwave made a large pop and unit went dead. Found circuit boards with charring on transformer, main controls and ribbon cable to user interface. User interface with ribbon cable is showing nla from marcone, and servall. Not able to check other functions at this time without proper voltage from control. Will need to replace transformer, controls and user interface before able to verify functionality of other components. Will need authorization as well. Left breaker in off state due to electrical failure.
Near Lago Vista, TX 78645
Thomas L.
Job Details: 08/16/2018
Arrived on site for not dispensing ice through the door. Replaced worn shaft. The other parts were not needed. All water connections were dry.
Near Leander, TX 78641
Lou
Job Details: 08/16/2018
arrived on site to inspect washer leaking from underneath and at the water valve. Upon further inspection, I found that the water valve was the main cause for the leaking water. I advised the customer of my findings then removed and replaced the water valve and tested the unit. Unit operated as designed. No water leaks after repair completed. Job completed.
Near Round Rock, TX 78664
Nathaniel B.
Job Details: 08/16/2018
Model WRF535SWHZ00, Arrived on call for unit is cooling but not cold enough, found that fresh food is at room temp but freezer is at o degrees, found all sensors passed and then when checked damper operation found that it would not open but when it said open checked ac volts from red to yellow red at damper and got 119 ac volts but damper not opening, replaced damper and checked operation and know damper is opening and closing as it should, call complete, no water leaks at time of call, call complete
Near Round Rock, TX 78664
Nathaniel B.
Job Details: 08/16/2018
Model WRF535SWHZ00, Arrived on call for unit is cooling but not cold enough, found that fresh food is at room temp but freezer is at o degrees, found all sensors passed and then when checked damper operation found that it would not open but when it said open checked ac volts from red to yellow red at damper and got 119 ac volts but damper not opening, replaced damper and checked operation and know damper is opening and closing as it should, call complete, no water leaks at time of call, call complete
Near Georgetown, TX 78633
Dona
Job Details: 08/16/2018
Arrived on site for bake element started on fire, found left side of bake element started to burn apart. Replaced bake element and verified operations. Temperatures check good. Charged $117.21 for element and labor WO120-$179.99 tax $24.52. Total of 321.72.
Near Woodway, TX 76712
Arthur B.
Job Details: 08/16/2018
MDBH968AWB3 (Dishwasher) - Arrived onsite to install control panel to dishwasher from tech’s prior diagnosis. Removed faulty control panel and installed new replacement. Tested unit. All lights works as intended. Unit fills,washes,drain and heats as intended. Control was not needed. All water connections were dry at time of service.
Near Pflugerville, TX 78660
Nathaniel B.
Job Details: 08/16/2018
Model WRF993FIFM00, Arrived on call for unit not cooling and ice maker not making ice, called whirlpool tech line and talked to mark , file number 7722726814, test 128 control is version 700 which is the updated control and was instructed to install updated cover and was given instruction to place evap sensor on copper above the weld on suction line, installed parts and instructed customer to allow for 24-48 hours for proper cooling, no water leaks after repair, call complete.
Near Pflugerville, TX 78660
Nathaniel B.
Job Details: 08/16/2018
Model WRF993FIFM00, Arrived on call for unit not cooling and ice maker not making ice, called whirlpool tech line and talked to mark , file number 7722726814, test 128 control is version 700 which is the updated control and was instructed to install updated cover and was given instruction to place evap sensor on copper above the weld on suction line, installed parts and instructed customer to allow for 24-48 hours for proper cooling, no water leaks after repair, call complete.
Near Austin, TX 78723
Robert
Job Details: 08/16/2018
WGD75HEFW0 Arrived on job for complaints of it starting found loose connection at Control. Reconnect power supply and test operation normal. Job complete no gas leaks detected
Near Austin, TX 78723
Robert
Job Details: 08/16/2018
WDF520PADM7 Arrived on job for complaints of not running. Found loose connection at junction box. After correcting wire issue. Test washer operation normal. Job complete
Near Lago Vista, TX 78645
Thomas L.
Job Details: 08/16/2018
Arrived on site for no cool in freezer. Found that the controls were not switching the three-way refrigerant valve And that the left track of the upper drawer was binding. Replaced all parts. All water connections were dried.
Near Georgetown, TX 78633
Lou
Job Details: 08/16/2018
arrived on site to install previously diagnosed and ordered parts. I disconnected the power from the unit, removed the water valve and drain pump hose then removed the unit from its place under the cabinet. I transferred all components from the old tub to the new tub and installed new tracks. Once done transferring all components, I re-installed the new tub with components under the cabinet re-installed the water valve and drain hose and then reconnected the power connections. I placed the unit in diagnostics and tested and the unit operated as designed. No water leaks observed during service, job completed.
Near Waco, TX 76710
Arthur B.
Job Details: 08/16/2018
CWE4800ACB (Wall Oven) - Arrived onsite for customer complaint of wall oven bake feature is not coming on. Tested unit and found baker relay not closing to turn on element. Unit will need new control to complete repair. Found control is no longer available. Advised customer will be in touch by AHS for options. No other issues found.
Near Waco, TX 76708
Arthur B.
Job Details: 08/16/2018
RTW4340SQ0 (Top Load Washer) - Arrived onsite to install new lid switch to top load washer from prior tech’s diagnosis. Removed console and removed faulty door switch. Installed new replacement and tested unit. Unit now fills,agitates,drain and spins as intended. No other issues found. All water connections were dry at time of service.
Near Austin, TX 78738
Brandon
Job Details: 08/16/2018
Arrived on site for no ice production in ice machine, found grid cutter was broken. I replaced grid cutter, unit tested good. Water lines were dry at time of service
Near Point Venture, TX 78645
Thomas L.
Job Details: 08/16/2018
Arrived on site as unit runs for a few seconds and then stops. Found improper voltages to outlets. Customer to correct. New unit no lent.
Near Round Rock, TX 78664
Nathaniel B.
Job Details: 08/16/2018
Model WDF530PAYW7, Arrived on call for middle sprayer part has came off and water is not going through it, checked for error codes and got 10-1 which is dispenser electrical problem found 115 ac volts to dispenser but dispenser door will not open , 5-2 which is door stuck closed which found no door switch issue then found manifold for top rack is warped and keeps allowing rubber bushing for manifold to fall off and also wheel for top front left rack is broken, manifold 61.47, wheel 14.46, dispenser 116.52, svc/labor dw295 199.99 which = 392.44 plus tax 32.38 which = 424.82, customer approved repair, collected service fee today of 99.99 plus tax which =108.24 no water leaks at time of call, call complete. Will collect remaining balance on returnAlso instructed customer on soap and rinse aid use and cleanings of dishwasher and to run hot water at sink before starting dishwasher.
Near Round Rock, TX 78664
Nathaniel B.
Job Details: 08/16/2018
Model WDF530PAYW7, Arrived on call for middle sprayer part has came off and water is not going through it, checked for error codes and got 10-1 which is dispenser electrical problem found 115 ac volts to dispenser but dispenser door will not open , 5-2 which is door stuck closed which found no door switch issue then found manifold for top rack is warped and keeps allowing rubber bushing for manifold to fall off and also wheel for top front left rack is broken, manifold 61.47, wheel 14.46, dispenser 116.52, svc/labor dw295 199.99 which = 392.44 plus tax 32.38 which = 424.82, customer approved repair, collected service fee today of 99.99 plus tax which =108.24 no water leaks at time of call, call complete. Will collect remaining balance on returnAlso instructed customer on soap and rinse aid use and cleanings of dishwasher and to run hot water at sink before starting dishwasher.
Near Georgetown, TX 78633
Dona
Job Details: 08/16/2018
Arrived on site to replace upper slides, would need to pull unit out of wall, customer states that unit has now been working since GC adjusted the slides. Customer does not want unit pulled out of the wall again. Customer is satisfied with the way unit is running now. Unit is heating and running correctly. All water connections dry.
Near Georgetown, TX 78633
Dona
Job Details: 08/16/2018
Arrived on site to replace upper slides, would need to pull unit out of wall, customer states that unit has now been working since GC adjusted the slides. Customer does not want unit pulled out of the wall again. Customer is satisfied with the way unit is running now. All water connections dry.
Near Waco, TX 76706
Arthur B.
Job Details: 08/16/2018
MVWX700XL2 (Top Load Washer) - Arrived onsite for customer complaint of top load washer not spinning clothes out. Ran diagnostics and got error codes F7E7(Could Not Reach Target RPM),F7E1 (Basket Speed Fault). Tilted unit up to inspect actuator and capacitor and motor. All harnesses check ok. Tested manual spin and found motor would cut in and out. Removed control and installed updated new replacement. Reassembled. Calibrated unit. Unit completed successfully. Tested unit. Unit now fills,agitates,drain and spins with no issues. All water connections were dry at time of service.
Near Austin, TX 78749
Kevin
Job Details: 08/16/2018
Arrived on site and replaced drain tube diagnosed on previous visit, after replacement removed ice from freezer and insured evaporator drain is clear. No water leaks from connections at time of service, job complete.
Near Georgetown, TX 78633
Dona
Job Details: 08/16/2018
Arrived on site to replace washplate that was worn down. Replaced washplate, filled unit and let cycle to verify all operations check good. No errors, unit fills, agitates, drains and spins correctly. All water connections dry. Charged 293.78 full amount for repair to card. Labor tl350-169.99 and part 101.40 tax 22.39.
Near Pflugerville, TX 78660
Scott
Job Details: 08/16/2018
Leaking front load washer
Near Jonestown, TX 78645
Thomas L.
Job Details: 08/16/2018
Arrived on site for Noisey, intermittent operation as well as the unit falls out of cabinet. Unit is secured to a price of wood at the bottom right side of cabinet. That wood is split and no longer is holding unit securely in the cabinet. Today both drawers are working properly with no water leaks. With unit loose, it is possible that at times it allows water to spill and wer flood sensor. Customer will need to secure unit and then see how unit operates .
Near Waco, TX 76707
Arthur B.
Job Details: 08/16/2018
ASI2575FRS00 (SxS Refrigerator) - Arrived onsite for customer complaint of SxS refrigerator not cooling properly. Found defrost timer LED indicator light would not reset. Removed and replaced defrost timer and installed new replacement. Reassembled. Unit came on and began cooling immediately. No other issues found. All water connections were dry at time of service.
Near Georgetown, TX 78633
Dona
Job Details: 08/16/2018
Arrived on site for frost build up on back right wall of freezer, found right hand lower side of cavity in freezer,with gap with no sealant allowing for airflow. Resealed unit and checked seals all operations check good, all water connections dry. Temps check good in fridge and freezer.
Near Cedar Park, TX 78613
Thomas L.
Job Details: 08/16/2018
Arrived on site for the unit freezing food in the entire fresh food section. With unit at lowest setting temps are correct. Any other setting, everything gets rock solid frozen. Please continue with ordering user interface and main control.
Near Austin, TX 78726
Wesley
Job Details: 08/16/2018
WED4815EW1 Arrived on site and found unit with load grinding. Partially disassembled to inspect. Tested unit after disassembly and grinding ceased. Assembled and tested. All checks good. Unit now operating as designed. No parts needed.
Near Round Rock, TX 78664
Nathaniel B.
Job Details: 08/16/2018
Model ASD2522WRW06, Arrived on call for unit not cooling, found icemaker is making ice and unit is cooling, found both controls set to coldest setting and freezer is at 5 degrees and fresh food is at 40 degrees on product, found damper is a solid block of ice preventing good air flow to the fresh food section, found were inside liner meets outer cabinet on both sections will need to be sealed with white silicone and will need to order damper and thermostat saw no defrost issue on back evap cover of freezer, will order sealant and damper and t-stat, will reschedule for 8/18/18, no water leaks at time of call.
Near Round Rock, TX 78664
Nathaniel B.
Job Details: 08/16/2018
Model ASD2522WRW06, Arrived on call for unit not cooling, found icemaker is making ice and unit is cooling, found both controls set to coldest setting and freezer is at 5 degrees and fresh food is at 40 degrees on product, found damper is a solid block of ice preventing good air flow to the fresh food section, found were inside liner meets outer cabinet on both sections will need to be sealed with white silicone and will need to order damper and thermostat saw no defrost issue on back evap cover of freezer, will order sealant and damper and t-stat, will reschedule for 8/18/18, no water leaks at time of call.
Near Waco, TX 76706
Arthur B.
Job Details: 08/16/2018
WTW6800WB1 (Top Load Washer) - Arrived onsite for customer complaint of top load washer not agitating. Removed washplate to attempt to removed inner basket. Found inner basket seized to shaft. Unit will need new outer tub and inner basket to complete repair. AHS must approve parts before R/S. OF to R/S. All water connections were dry at time of service.
Near Leander, TX 78641
Thomas L.
Job Details: 08/16/2018
Arrived on site for unit overfilling with ice condition. Tested bin thermistor. Thermistor is out of its normal resistance range. Replaced thermistor. All operations tested correctly in diagnostics. All water connections are dry.
Near Georgetown, TX 78628
Lou
Job Details: 08/15/2018
arrived on site to inspect oven element broken. Upon further inspection, I found that the bake element was burnt in two. I quoted the customer CO120 $139.99 for diagnosis/labor fee and $82.48 for the bake element for a total including tax of $240.82. Customer agreed to the repair and paid diagnosis fee of $108.24 with the remaining balance being $132.58 which the customer agreed to pay when the repair is done. I am ordering a bake element and return service is scheduled for 08/16/18.
Near Killeen, TX 76549
Arthur B.
Job Details: 08/15/2018
UMV1160CB3 (OTR Microwave) - Arrived onsite for customer complaint of vent fan not blowing on OTR microwave and not heating. Tested unit and found blower fan is not moving causing magnetron to overheat. Ordering blower fan assembly to complete repair. R/S customer for 8/20. Advised not to use until repairs are completed.