Near Cedar Park, TX 78613
Jerry C.
Job Details: 02/26/2018
MED5770TQ0 Arrived to inspect noise. I found a prior service company had completely disassembled the unit and I quoted the customer for the repair kit and reassembly. I removed and replaced the failed rollers, belt and idler and reassembled the unit. It tested good and operated as designed. Lint removed from chassis.
Near Liberty Hill, TX 78642
Thomas L.
Job Details: 02/26/2018
Arrived on site for improper function, found left front knob and bezel off centered causing shaft to bind. Adjusted bezel for proper turn function. Found no problems with spark module. Verified operations of all burners. All checked to spec.
Near Austin, TX 78745
Luis
Job Details: 02/26/2018
Refrigerator-IX5BBEXDS00-defrosted evaporator replaced temperature sensor
Near Austin, TX 78745
Luis
Job Details: 02/26/2018
Near Austin, TX 78717
Thomas L.
Job Details: 02/26/2018
Arrived on site for noise and intermittent operation on turntable, once disassembled found, turn shaft to motor plastic piece is completely corroded and split. Replaced motor. Kali assisted with part and reschedule date 3/1/18 Thursday.
Near Austin, TX 78726
Thomas L.
Job Details: 02/26/2018
Arrived on site for dispenser not opening, replaced faulty dispenser and control that was not displaying correctly. Replaced verified operations unit checked to spec. All water connections dry.
Near Georgetown, TX 78628
Jonathan S
Job Details: 02/26/2018
Whirlpool dryer . Not heating
Near Austin, TX 78721
Luis
Job Details: 02/26/2018
Refrigerator-WRF560SMYM05 frozen drain cleared ice cleared drain.
Near Austin, TX 78717
Thomas L.
Job Details: 02/26/2018
Arrived on site for broken knob, found shaft snapped at ui on washer. Customer does not want to go through with repair at this time. Unit not hooked to water at this time.
Near Austin, TX 78746
Luis
Job Details: 02/26/2018
Icemachine. No ice replaced water valve and pump assembly
Near Austin, TX 78748
Leonardo
Job Details: 02/26/2018
Near Austin, TX 78748
Leonardo
Job Details: 02/26/2018
Whirlpool dishwasher, model WDT970SAHZ0. Arrived on site to test unit for upper rack coming off track. Test unit and found wheels of track. Secured wheels to track test unit and unit test good job complete no leaks present.
Near Liberty Hill, TX 78642
Thomas L.
Job Details: 02/26/2018
Removed and replace leaking dispenser. Tested unit and operations were correct. Water connections were all dry.
Near Liberty Hill, TX 78642
Thomas L.
Job Details: 02/26/2018
Removed and replace leaking dispenser. Tested unit and operations were correct. Water connections were all dry.
Near New Braunfels, TX 78132
Daniel A.
Job Details: 02/24/2018
WDT970SAHZ0 Not cleaning dishes. Defective motor/sump. Replaced motor/sump Assy. Verified no leaks from inlet/drain hoses. Ran wash cycle. Normal operation after service
Near Austin, TX 78703
Joseph C.
Job Details: 02/23/2018
LTE5243DQ6 Arrived on site for shaky and wobbly washer basket complaint. Per my previous diagnosis, removed and replaced base frame and springs. Tested unit. All checks good. No leaks detected, at time of service.
Near Georgetown, TX 78633
Thomas L.
Job Details: 02/23/2018
Arrived on site for no ice production, found inoperative ice maker. Replaced ice maker. All water connections dry.
Near Austin, TX 78758
Joseph C.
Job Details: 02/23/2018
WTW4816FW1 Arrived on site for bad lid lock complaint. Inspected unit found lid lock faulty. Removed and replaced lid lock. Calibrated unit. No leaks detected, at time of service.
Near Georgetown, TX 78633
Thomas L.
Job Details: 02/23/2018
Arrived on site for no heat and no operation, found open upper thermal fuse. Replaced thermal fuse, verified temps. Unit checked good. Paid $252.64 check #1037
Near Killeen, TX 76543
Steve C.
Job Details: 02/23/2018
Near Austin, TX 78723
Joseph C.
Job Details: 02/23/2018
GU3200XTXY3 arrived on site for water left at bottom of unit after wash complaint. Inspected unit and found drain pump impeller separated from pop. Removed and replaced drain pump. Tested unit. Unit is performing as designed. No leaks detected, at time of service. Parts are $81.02. Labor is $159.99. Total collected is $260.89.
Near Austin, TX 78723
Joseph C.
Job Details: 02/23/2018
Near Austin, TX 78723
Joseph C.
Job Details: 02/23/2018
JDB9000CWS3 Arrived on site for “leaking from lower left corner of door” complaint. Inspected unit and found I’ll fitting gasket. Removed and replaced gasket. Tested unit. Unit is performing as designed. No leaks detected, at time of service.
Near Austin, TX 78723
Joseph C.
Job Details: 02/23/2018
JDB9000CWS3 Arrived on site for “leaking from lower left corner of door” complaint. Inspected unit and found I’ll fitting gasket. Removed and replaced gasket. Tested unit. Unit is performing as designed. No leaks detected, at time of service.
Near Pflugerville, TX 78660
Jonathan S
Job Details: 02/23/2018
Whirlpool dishwasher model WDT710PAYM. Leaking water
Near Round Rock, TX 78681
Jerry C.
Job Details: 02/23/2018
KBFA20ERSS01 arrived on site for an ice maker not working. During inspection of the ice maker, I found that the ice maker had stalled and unit had over filled. Removed ice maker assembly and installed new ice maker. Tested new ice maker and it operated as designed. RF 360 $169.99; ice maker $129.43; tax $24.70; total job $324.12. No leaks observed during service.
Near Pflugerville, TX 78660
Jonathan S
Job Details: 02/23/2018
Whirlpool washer model # MHW5100DW0. Leaking water
Near Horseshoe Bay, TX 78657
Thomas L.
Job Details: 02/23/2018
Arrived on site for flashing lights, found 3 blinking lights indicating bad thermistor, will order part and return Wednesday, Tommy will not charge for part. All water connections dry. Watched two slabs of ice when thermistor was bypassed left unit in off position.
Near Austin, TX 78756
Joseph C.
Job Details: 02/23/2018
JDB9000CWS3 Arrived on site for “leaking from lower left corner of door” complaint. Inspected unit and found I’ll fitting gasket. Removed and replaced gasket. Tested unit. Unit is performing as designed. No leaks detected, at time of service.
Near Killeen, TX 76542
Steve C.
Job Details: 02/23/2018
Near Horseshoe Bay, TX 78657
Thomas L.
Job Details: 02/23/2018
Arrived on site for no heat on burners, replaced two right burners and left griddle burner. Verified operations, unit checked good.
Near Burnet, TX 78611
Thomas L.
Job Details: 02/23/2018
Arrived on site for no wash, found seized motor. Will need to order. Erika assisted with part. All water connections dry.
Near Austin, TX 78751
Joseph C.
Job Details: 02/23/2018
KODE300ESS02 Arrived on site to check oven for F2 E1 error. Found buttons unresponsive on control panel. Replaced new control panel and ran all test on unit. All buttons are responsive, cooling fan is functioning properly. Advise customer that steaming things on the top rack for broiling may cause problems and to make sure the door stays completely shut.
Near Liberty Hill, TX 78642
Thomas L.
Job Details: 02/23/2018
Arrived on site for no spin. Replaced actuator, ran through diagnostics. Checked incoming water through machine checked ok. All water connections dry. Collected remainder of call $170.09 credit card.
Near Cedar Park, TX 78613
Jerry C.
Job Details: 02/22/2018
KEBC107KSS05 arrived on site for broken door glass. Found broken glass and remove and replaced inner glass from door. Removed remnants of broken glass from inside unit. Quoted customer for interior glass $79.30, 2X light assemblies $41.48 ea. WO220 $169.99 and WO300. Installed glass and temperature tested and unit tested within specifications. Customer paid $188.54 today remaining cost is $263.13. Office to order parts and schedule return.
Near Georgetown, TX 78633
Thomas L.
Job Details: 02/22/2018
Arrived on site for f5e1 error, found error. Reset error on control. Verified temperatures on preheat, no further issues at this time.
Near Georgetown, TX 78633
Thomas L.
Job Details: 02/22/2018
Arrived on site for no ice production, found inlet tube with ice blockage, removed, valve cycled, all water connections dry.
Near Liberty Hill, TX 78642
Mike C.
Job Details: 02/22/2018
Whirlpool microwave WMH32519FS0 Arrived to find interior light not coming on when opening the door and then not starting a heating cycle. Found door switches and interlocks bad. Installed new interlocks with door switches and checked operation, checked good.
Near Round Rock, TX 78664
Thomas L.
Job Details: 02/22/2018
Arrived on site for no heat, found neutral line loose on dryer side tightened neutral. Venting is clean.
Near Driftwood, TX 78619
Connor M.
Job Details: 02/22/2018
WDT920SADM2 whirlpool dishwasher Arrived on site to test unit for leaking water during use. Ran cycle and monitored. No leaks during run time. Found evidence of over soaping condition indicated by where the water appears to have been and wash habits stated by customer. Unit working properly at time of service. Instruct customer on proper use and care. No leaks detetced. Collected srvc via cc.
Near Austin, TX 78737
Connor M.
Job Details: 02/22/2018
KFIS29PBMS00 kitchenaid refrigerator Arrived on site to test unit for frost build up in rc. Found ice build up at rear adapter on return air gasket. No frost on ff evap. Unit maintaining temps properly. Will need gaskets and adapter. Sw approved 2/27
Near Round Rock, TX 78664
Thomas L.
Job Details: 02/22/2018
Arrived on site for screw that had fallen out of door, reseated and tightened all other screws. Verified operations, all water connections dry.
Near Round Rock, TX 78665
Thomas L.
Job Details: 02/22/2018
Arrived on site for dish rack sliding off slides, replaced right slide stop. Verified rack slides good and left stop good. All water connections dry.
Near Round Rock, TX 78665
Thomas L.
Job Details: 02/22/2018
Arrived on site for dish rack sliding off slides, replaced right slide stop. Verified rack slides good and left stop good. All water connections dry.
Near Round Rock, TX 78665
Thomas L.
Job Details: 02/22/2018
Arrived on site for no operation, found faulty user interface. Will order user interface, rescheduled for Tuesday, Erika assisted.
Near Liberty Hill, TX 78642
Mike C.
Job Details: 02/22/2018
Whirlpool microwave WMH31017FS Arrived to find the interior light not coming on when opening the door and then not starting a heating cycle. Found door switches and interlocks bad on unit. Installed new upper and lower interlocks with door switches and checked operation, checked good.
Near Georgetown, TX 78633
Thomas L.
Job Details: 02/22/2018
Arrived on site for no cool condition. Found dye drier cracked. Replaced with new dye drier, checked for cooling unit cooling. Water was from melting ice bin. All water connections checked dry.
Near Austin, TX 78749
Connor M.
Job Details: 02/22/2018
WRF535SWHW00 Arrived on site to test unit for door issues. Found after leveling unit that doors were uneven front to back. Unable to correct issue. Ordering doors for return. Office to schedule directly.
Near Leander, TX 78641
Jerry C.
Job Details: 02/22/2018
KRFF507ESS01 arrived, on site for fridge door making noises and internal lights issue. Pulled refrigerator out and replaced LED supply board. I inspected the drain and found it sagging and sealed it. Returned unit to its correct place and squared the cabinet and leveled. I set the right door to match the height of the left and verified cabinet square. The ice maker housing adapter was incorrectly mounted and was tilted. I removed and corrected the adapter mounting and ensured complete ice maker housing engagement to the rear of the liner. Operational test good, no leaks observed during service.
Near Round Rock, TX 78681
Jonathan S
Job Details: 02/22/2018
Whirlpool refrigerator model#WRT519SZDB02. Not cooling.
Near Georgetown, TX 78626
Thomas L.
Job Details: 02/22/2018
Arrived on site for oven not moving past 175 degrees, found control was set to Celsius not Fahrenheit. Reset unit to Fahrenheit, verified temperatures. Unit checks to spec. Customer states that the unit did not work since the last repair.
Near Nolanville, TX 76559
Chase
Job Details: 02/21/2018
Arrived. On site for runaway temps and control lockdown. Replaced control and probe, verified operations. Temps Ckd good.
Near Belton, TX 76513
Chase
Job Details: 02/21/2018
Arrived on site for stall in spin cycle, replaced worn down washplate, verified operations and checked for errors, checked all water connections-were dry.
Near Georgetown, TX 78633
Thomas L.
Job Details: 02/21/2018
Arrived on site to install parts. Replaced the controls and the sensor as temperatures would not maintain properly. Tested Unit and unit operated as designed. The customer had not received her new unit tag from the manufacturer as of this date.
Near Temple, TX 76502
Chase
Job Details: 02/21/2018
Arrived on site for no ice production, found ice maker burned across motor, replaced verified operations. All water connections dry.
Near Temple, TX 76502
Chase
Job Details: 02/21/2018
Arrived on site for no ice production, found ice maker burned across motor, replaced verified operations. All water connections dry.
Near Salado, TX 76571
Chase
Job Details: 02/21/2018
Arrived on site for intermittent spin. Unit had been calibrated prior visit, lid lock is engaging through full cycle, found no solid errors to ensure lid lock failure. Customer said that washer worked since the previous tech calibrated. No part is needed at this time. All water connections dry.
Near Burnet, TX 78611
Thomas L.
Job Details: 02/21/2018
Arriv3d on site for ice machine not making ice and making loud dishwasher sound. Turned the unit on and as the bowl filled with water found that the recirculating pump tube was not connected and was forcing water out of he bowl into the compartment. Attached the tube and the unit began to function properly. No leaks found/all connections were dry.
Near Salado, TX 76571
Chase
Job Details: 02/21/2018
Arrived on site for washer continually filling with water even when power is off to unit, found mechanically open water valve, replaced valve tested operations, pressure switch engages, spin sounds normal, wash cycle at pace. All water connections tested dry. Customer already had unit pullled away from wall at time of arrival.
Near Marble Falls, TX 78654
Thomas L.
Job Details: 02/21/2018
Arrived on site for a dryer not heating but drum spins. Found thermal cutoff defective. Removed and installed new thermal cutoff kit. Tested unit and unit heated as expected. Dryer venting is cleared. The dryer was in the driveway under carport and customer was not home, but gave permission to service dryer.
Near Round Rock, TX 78665
Jonathan S
Job Details: 02/21/2018
Whirlpool dryer model GEW9250PL0. Not heating
Near Salado, TX 76571
Chase
Job Details: 02/21/2018
Arrived on site for long. Checked functionality of wash motors, heater, waater temmp, all functionally checked correctly. Customers water is hard, have advised customer. On detergent, water temperatures, water softner. At this time unit is working to mfg specification. All water. Connections are. Dry.
Near Marble Falls, TX 78654
Thomas L.
Job Details: 02/21/2018
Arrived on site for an F20 error code. Ran unit in diagnostic mode and the F20 code appeared. F20 code reads that the pressure switch trip is not detecting. Unplugged unit and removed old pressure switch to find a crack in the housing; blew into the pressure switch tube to check air flow and it checked good. Installed new pressure switch, plugged unit in and tested unit. Unit operated as expected. No leaks found/all connections were dry. We entered the home via the garage door and left the home via the garage door. Notified the customer via telephone.
Near Horseshoe Bay, TX 78657
Thomas L.
Job Details: 02/21/2018
Arrived on site for an F20 error code. Ran unit in diagnostic mode and the F20 code appeared. F20 code reads that the pressure switch trip is not detecting. Unplugged unit and removed old pressure switch to find a crack in the housing; blew into the pressure switch tube to check air flow and it checked good. Installed new pressure switch, plugged unit in and tested unit. Unit operated as expected. No leaks found/all connections were dry. We entered the home via the garage door and left the home via the garage door. Notified the customer via telephone.
Near Georgetown, TX 78628
Chase
Job Details: 02/21/2018
Arrived on site. Checked dryer for intermittent no operation. Customer stated that unit will not power on intermittently and at times display will fade. Upon arrival dryer is functioning properly. Verified line voltage to unit from wall outlet and line voltage from main control. Mechanically dryer checks good. Rollers, idler and belt sound good. Due to issue with elecronics it could be an issue with main control, user interface or both and it cannot be determined at this time. The user interface is Discontinued. To replace the main control quote would be- Service (DR310)-$149.99-Part-(main control)-$246.69. Advised customer that there could be damage to both electronics assemblies and recommendation would be to repalce both. Due to user interface being Disconitued I would not recommend further repair on this unit. Collected $108.24 diagnostic fee today. Job complete
Near Round Rock, TX 78664
Jonathan S
Job Details: 02/21/2018
Whirlpool dryer model # MEDC215. Not heating at all.
Near Georgetown, TX 78633
Chase
Job Details: 02/21/2018
Arrived on site for low to no ice production, found e 2 error for stalled ice motor, replaced ice maker. Verified operations of Ice Maker, ckd gaskets, and temperatures. All water lines dry.
Near Killeen, TX 76542
Steve C.
Job Details: 02/21/2018
Near Burnet, TX 78611
Thomas L.
Job Details: 02/21/2018
Arrived on site for left fridge door making noises when opening. Adjusted the hinge and the noise stopped. Observed no leaks all connections were dry.
Near Leander, TX 78641
Jerry C.
Job Details: 02/20/2018
MEDX700AG0 arrived on site for dryer not heating/drying. Checked voltage to thermostat and checked good. Checked voltage to element and found it to be open. Removed old element and installed new element. Tested unit and found the element heat up and cool back down. Unit operates as expected. DRE310-$159.99 labor and WP3387747 Element-$96.67...total=$277.83. Customer paid in full with card.
Near Leander, TX 78641
Jerry C.
Job Details: 02/20/2018
MVWB835DW1 arrived on site for grease/black marks on certain garments. Discussed with customer loading strategies/techniques. Advised customer to use deep water wash cycle with extra rinse and deep clean modifiers. I also advised the customer warmer wash temperatures may help with residue. Placed washer in test mode and tested good. No leaks found during service.
Near Round Rock, TX 78681
Thomas L.
Job Details: 02/20/2018
Arrived on site for abnormal noise operation, replaced compressor under service pointer W10783614, all water connections are dry.
Near Lago Vista, TX 78645
Jerry C.
Job Details: 02/20/2018
WRX735SDBM04 arrived on site for no lighting in the drawer of refrigerator. After checking the wiring of the drawer lights and pulling the lights housing, I found that one of the drawer lights was not completely connected. The light was connected and both lights worked as designed. No leaks found and all connections were dry.
Near Round Rock, TX 78681
Thomas L.
Job Details: 02/20/2018
Arrived on site for residue on clothes. Customer gave me examples of the clothes with splotches on them. Found no fault codes in diagnostics. Customer has been educated on laundry soaps temperatures cycles etc. water connections are dry. Contacted tech line and spoke with Robert ref # is 7721328678 . No repairs are to be further done since kit has been installed. I was advised to refer the customer to the Customer Experince Center at 800-253-1301
We serviced a
Arrived on site for gas smell on dryer found leak on burner. Will need a burner. Customer declines repair at this time. Gas has been shut off to unit. Dryer vent is clean. Customer removed back panel, so was left off. Work 209.99
Model Burner 257.20
Near Round Rock, TX 78664
Thomas L.
Job Details: 02/20/2018
Sub
Near Cedar Park, TX 78613
Jerry C.
Job Details: 02/20/2018
KMBP100ESS01 Arrived to instal previously diagnosed and ordered part. I emoted and replaced the interlock assembly and tested. The issue was corrected and I verified the switches had failed. During further inspection I found a lip at the front of the cabinet and it is causing the rear of the unit to drop down approximately 1/4 inch, flexing the front of the chassis in at the top and causing interlock switch failure. The installation will require either the lip of the cabinet removed, or a spacer equaling the height of the lip or slightly above, to be added under the unit. Operational test good.
Near Round Rock, TX 78665
Thomas L.
Job Details: 02/20/2018
Arrived on site for dryer shredding clothes. Found moisture sensor in rear bowed and catching clothing, replaced with new sensor. Unit checked ok. Dryer venting is clean.
Near Round Rock, TX 78665
Thomas L.
Job Details: 02/20/2018
Arrived on site for flashing lights on rinse and spin, not completing cycle. Found actuator error, lid lock error, and control error on spin. Will need to order lid lock assy W10838613, actuator W10913953, and electronic control W11116590. Erika assisted with parts and return date. All water connections dry.
Near New Braunfels, TX 78130
Connor M.
Job Details: 02/20/2018
MMV4205FZ3maytag microwave Arrived on site to test unit for light not coming on. Cusomer had new bulb to replace old one, didnt work. Confirmed proper voltage at harness so i replace socket. Light still not coming on. Will need to replace control. Part is expart. Office to schedule directly.
Near New Braunfels, TX 78130
Connor M.
Job Details: 02/20/2018
LER3624JQ0 whirlpool dryer Arrived on site to test unit for drumm not turning. Found worn out idler pulley causing belt to come loose. Installed dryer repair kit and tested unit. Unit working properly. Informed customer of potential fire hazard from bad venting
Near Round Rock, TX 78665
Chase
Job Details: 02/19/2018
MVWB765FW arrived on site and replaced gear case which has failed bearing and seized spanner nut for top load washer. Reassembled washer and tested. All checks good
Near Leander, TX 78641
Jerry C.
Job Details: 02/19/2018
WRF993FIFM00 arrived to install previously diagnosed part. Removed broken control along with broken parts from housing; installed new control. Tested unit and operates as designed.
Near Marble Falls, TX 78654
Thomas L.
Job Details: 02/19/2018
Arrived on site for long cycles, found failed owi sensor. Replaced sensor, diagnostics checked good, all water connections dry.
Near Marble Falls, TX 78654
Thomas L.
Job Details: 02/19/2018
Arrived on site for flashing service light, found open thermostat.Replaced thermostat. Unit started cycling error stopped. All water connections dry. Control $45.79 Work $149.99 Sub $195.78 Tax $16.15 Total $211.93
Near Austin, TX 78759
Cliff
Job Details: 02/19/2018
Jennair oven JJW3830DS00, Arrived on site to diagnose an oven that will not update with Jenn air through Wi-Fi. Tested unit and found Wi-Fi board not operating properly and preventing update. Replaced control panel and tested unit. Found unit is now connected to jennair service properly and all is operating properly at this time.
Near Horseshoe Bay, TX 78657
Thomas L.
Job Details: 02/19/2018
Arrived for no ice production, found ice paddle on door with incorrect dc voltage. Replaced verified ops checked good. Replaced ice bin on door that was broken. All water connections dry.
Near Leander, TX 78641
Jerry C.
Job Details: 02/19/2018
KRFC704FBS00 arrived on site to install previously diagnosed and ordered parts. Use heat to reform new gasket. Once verified replacement gasket in condition to install, removed and replaced old gasket with new. No leaks found during service; all connections were dry.
Near Harker Heights, TX 76548
Mike G.
Job Details: 02/19/2018
GS6NHAXVA00 , Arrived on site for unit not making ice checked unit and found that the icemaker is working and when icemaker calls for water water is spraying out of the side checked unit and found that the fill chut to icemaker is blocked with ice and froze up removed icemaker and flushed out icemaker and checked unit and found that the unit checked fine at this time.... checked unit for water leaks and no leaks found at time of srv....
Near Harker Heights, TX 76548
Mike G.
Job Details: 02/19/2018
GS6NHAXVA00 , Arrived on site for unit not making ice checked unit and found that the icemaker is working and when icemaker calls for water water is spraying out of the side checked unit and found that the fill chut to icemaker is blocked with ice and froze up removed icemaker and flushed out icemaker and checked unit and found that the unit checked fine at this time.... checked unit for water leaks and no leaks found at time of srv....
Near Kingsland, TX 78639
Thomas L.
Job Details: 02/19/2018
Arrived on site for dripping water and ice build up in freezer, found bowed door and un malleable gasket. Replaced door and seal, verified ops unit did ok. Water connections dry.
Near Georgetown, TX 78633
Thomas L.
Job Details: 02/17/2018
Arrived on site to install parts. Replaced opened fuse and slow turning fan motor. Tested unit and unit operated as designed.
Near Killeen, TX 76543
Thomas L.
Job Details: 02/17/2018
Arrived on site to install parts. Tested unit and found motor would not start on its own. Removed and installed motor and blower wheel. Tested unit and unit operated as designed.
Near Nolanville, TX 76559
Thomas L.
Job Details: 02/17/2018
Arrived on site to install part. Tested unit in service mode and 7-1 code appeared. Ran diagnostics to clear control and customer is able to run unit. No leaks found; all connections were dry.
Near Belton, TX 76513
Thomas L.
Job Details: 02/17/2018
Arrived on site to install parts. Installed open components per manufacturer. Will also need to install fan and thermostat. Office to order parts and reschedule. Microwave was not installed properly and sitting on the countertop in the unplugged position. Left unit unplugged at end of service.
Near Belton, TX 76513
Thomas L.
Job Details: 02/17/2018
Arrived on site for dispenser leaking and rusting. Found that the dispenser was jammed; unjammed the dispenser and it works as designed. Both doors have rust on facing and customer will report this to his extended warranty company. No leaks observed and customer reported no leaks. All connections were dry.
Near Temple, TX 76502
Thomas L.
Job Details: 02/17/2018
Arrived on site for dispenser leaking and rusting. Found that the dispenser was jammed; unjammed the dispenser and it works as designed. Both doors have rust on facing and customer will report this to his extended warranty company. No leaks observed and customer reported no leaks. All connections were dry.
Near Cedar Park, TX 78613
Jerry C.
Job Details: 02/16/2018
WTW5000DW1 arrived on site for a washer making a high pitched noise in the spin cycle. Tested unit in the service mode on the spin cycle and found the unit required cabinet adjustment and hardware tightening. Adjusted/tightened hardware, tested unit and operated correctly. The unit required the basket centered within chassis. No leaks found all connections were dry.
Near Georgetown, TX 78633
Thomas L.
Job Details: 02/16/2018
Replaced leaking icemaker, all connections dry.
Near Marble Falls, TX 78654
Thomas L.
Job Details: 02/16/2018
Arrived on site to replace shorted board that was caused by shorted pump, replaced both, unit recalibrated unit checked ok, in warehouse not hooked to water.
Near Austin, TX 78726
Jerry C.
Job Details: 02/16/2018
WRT311FZDM00 arrived to install part. Removed and replaced existing extension and tested. During service, I found large amount of moisture on the ceiling of fc. The left side of the fc door gasket was gapped one quarter inch along its entirety. I was able to re-bed the gasket and get it to seal correctly, through multiple tests. Advised customer to contact us if excessive moisture persists within the chassis. Operations are good; no leaks; all connections dry.