Appliance Repair Dale Texas

Appliance Express Rated 4.6 out of 5 stars based on 13 customer reviews

We serviced a
MAYTAG WASHER
Model MVWX655DW2
Near Dale, TX 78616
Andrey
Job Details: 03/08/2024
"Arrived on site to replace previously diagnosed parts, replaced tub,basket, wash-plate, hub, suspension, gear case, pump, belt, shift actuator, control and cam, tested unit unit is now running as designed, job complete"
We serviced a
MAYTAG WASHER
Model MVWX655DW2
Near Dale, TX 78616
Andrew
Job Details: 01/05/2024
"Arrived on site to replace previously diagnosed parts. Found unable to remove wash plate without causing damage. Unit is outside and exposed to elements. Recommend replacing gear case, belt, splutch, suspension, drain pump, hub nut, control, wash plate and actuator. Not confident repair would hold. Needing autho for parts and 2hrs on return visit. Office to make sure unit is supplied both hot and cold water and electricity. ; ordrng 1 W10902814 (Wash plate)"
We serviced a
WHIRLPOOL DISHWASHER
Model WDF540PADB3
Near Dale, TX 78616
Andrew
Job Details: 01/05/2024
"Arrived on site to inspect unit for no power and control panel being unresponsive. Upon closer inspection found voltage to be correct at junction box, ground not connected properly in junction box as well as wires being loose due to, too large of wire nuts used. Tightened ground and used smaller wire nuts to get better connection on wires. Tested unit, unit is running as intended. No leaks detected at this time. Job complete."
We serviced a
WHIRLPOOL DISHWASHER
Model WDF540PADB3
Near Dale, TX 78616
Matthew
Job Details: 12/22/2023
Arrived onsite for unit not powering on. Upon arrival inspected unit. Found console/control not responsive. Disassembled and found voltage to control at only 23 vac. Checked voltage at supply box and verified 123vac. Ordering Harness and control. Office to reschedule ; ordrng 1 W11227372 (Main harness)
We serviced a
WHIRLPOOL DRYER
Model WED4950HW0
Near Dale, TX 78616
Andrey
Job Details: 09/29/2023
"Arrived on site to test unit for long dry times, tested unit found vent test failed, removed lint trap and found that the air is blowing out instead of suction, disconnected vent from back of unit and it passed, stated to customer not to run unit until restriction has been removed, at this time job complete"
Leyla
Dale, Texas
07/25/2022
Very professional and helpful in explaining what the issue was with our washer. Thank you
Overall Experience
Linda
Dale, Texas
02/02/2021
Great service
Overall Experience
Margaret
Dale, Texas
03/05/2020
Great service! Thanks
Overall Experience
Anna
Dale, Texas
02/03/2020
have not used dryer yet because i was told not to use it until the vent is fixed so i do not know if dryer works properly or not. I have to get venting parts and fix that myself, so therefore cannot give a good rating.
Overall Experience
Johnnie
Dale, Texas
02/03/2020
Great job
Overall Experience